两相流流速的差动自相关测量法
引用本文:王卫国,周慎杰.两相流流速的差动自相关测量法[J].实验技术与管理,2006,23(9):39-41.
作者姓名:王卫国  周慎杰
作者单位:山东大学,机械工程学院,济南,250061
摘    要:该文提出了一种基于差动自相关原理的两相流流速测量方法,从理论上进行分析,指出该方法只产生一路信号,可降低对系统的对称性要求,简化电路,提高灵敏度和抗干扰能力,减少了相关分析的数据处理工作量,并采用电容式传感器建立了一套气固两相流流速测量系统.实验数据表明有较高的精确度和良好的重复性.

关 键 词:差动自相关  两相流  流速
文章编号:1002-4956(2006)09-0039-03
收稿时间:2005-11-10
修稿时间:2006-03-10

Differential auto-correlation measurement in velocity of two phase flow
WANG Wei-guo,ZHOU Shen-jie.Differential auto-correlation measurement in velocity of two phase flow[J].Experimental Technology and Management,2006,23(9):39-41.
Authors:WANG Wei-guo  ZHOU Shen-jie
Institution:School of Mechanical Engineering , Shandong University , Jinan 250061, China
Abstract:A measuring method of two phase flow rate based on the principle of differential auto-correlation is presented. Analysis in theory shows that one channel signal is simply produced by using this method, and that the system symmetry demands is reduced. A measuring system of gas- solid two phase flow rate is established by using capacitance transducer. The results of experimental analysis verified the anti-interference capability and sensitivity are enhanced. The research results also show that the system having higher precision and better repetition.
Keywords:differential auto-correlation  two phase flow  velocity of flow
本文献已被 CNKI 维普 万方数据 等数据库收录!