首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Relationship between maximal oxygen uptake and oxygen uptake attained during treadmill middle-distance running
Authors:James David V B  Sandals Leigh E  Draper Stephen B  Wood Dan M
Institution:Faculty of Sport, Health and Social Care, University of Gloucestershire, Gloucester, UK. djames@glos.ac.uk
Abstract:Traditionally, it has been assumed that during middle-distance running oxygen uptake (VO2) reaches its maximal value (VO2max) providing the event is of a sufficient duration; however, this assumption is largely based on observations in individuals with a relatively low VO2max. The aim of this study was to determine whether VO2max is related to the VO2 attained (i.e. VO2peak) during middle-distance running on a treadmill. Fifteen well-trained male runners (age 23.3 +/- 3.8 years, height 1.80 +/- 0.10 m, body mass 76.9 +/- 10.6 kg) volunteered to participate in the study. The participants undertook two 800-m trials to examine the reproducibility of the VO2 response. These two trials, together with a progressive test to determine VO2max, were completed in a randomized order. Oxygen uptake was determined throughout each test using 15-s Douglas bag collections. Following the application of a 30-s rolling average, the highest VO2 during the progressive test (i.e. VO2max) was compared with the highest VO2 during the 800-m trials (i.e. VO2peak) to examine the relationship between VO2max and the VO2 attained in the 800-m trials. For the 15 runners, VO2max was 58.9 +/- 7.1 ml x kg(-1) x min(-1). Two groups were formed using a median split based on VO2max. For the high and low VO2max groups, VO2max was 65.7 +/- 3.0 and 52.4 +/- 1.8 ml x kg(-1) x min(-1) respectively. The limits of agreement (95%) for test-retest reproducibility for the VO2 attained during the 800-m trials were +/- 3.5 ml x kg(-1) x min(-1) for a VO2peak of 50.6 ml x kg(-1) x min(-1) (the mean VO2peak for the low VO2max group) and +/- 2.3 ml x kg(-1) x min(-1) for a VO2peak of 59.0 ml x kg(-1) x min(-1) (the mean VO2peak for the high VO2max group), with a bias in VO2peak between the 800-m runs (i.e. the mean difference) of 1.2 ml x kg(-1) x min(-1). The VO2peak for the 800-m runs was 54.8 +/- 4.9 ml x kg(-1) x min(-1) for all 15 runners. For the high and low VO2max groups, VO2peak was 59.0 +/- 3.3 ml x kg(-1) x min(-1) (i.e. 90% VO2max) and 50.6 +/- 2.0 ml x kg(-1) x min(-1) (i.e. 97% VO2max) respectively. The negative relationship (-0.77) between VO2max and % VO2max attained for all 15 runners was significant (P = 0.001). These results demonstrate that (i) reproducibility is good and (ii) that VO2max is related to the %VO2max achieved, with participants with a higher VO2max achieving a lower %VO2max in an 800-m trial on a treadmill.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号