首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Optofluidic tweezer on a chip   总被引:1,自引:0,他引:1  
A novel method to realize an optical tweezer involving optofluidic operation in a microchannel is proposed. To manipulate the optical tweezer, light from an optical fiber is passed through both PDMS (polydimethylsiloxane)-air surface lenses and an optofluidic region, which is located in a control channel. Two liquids with different refractive indices (RIs) are introduced into the control channel to form two different flow patterns (i.e., laminar and segmented flows), depending on the liquid compositions, the channel geometry, and the flow rates. By altering the shapes of the interface of the two liquids in the optofluidic region, we can continuously or intermittently control the optical paths of the light. To demonstrate the functionality of the proposed method, optical tweezer operations on a chip are performed. Changing the flow pattern of two liquids with different RIs in the optofluidic region results in successful trapping of a 25 μm diameter microsphere and its displacement by 15 μm.  相似文献   

2.
A microheater and a thermal sensor were fabricated inside elastomeric polydimethylsiloxane microchannels by injecting silver paint (or other conductive materials) into the channels. With a high-precision control scheme, microheaters can be used for rapid heating, with precise temperature control and uniform thermal distribution. Using such a microheater and feedback system, a polymerase chain reaction experiment was carried out whereas the DNA was successfully amplified in 25 cycles, with 1 min per cycle.  相似文献   

3.
The effects of global warming, pollution in river effluents, and changing ocean currents can be studied by characterizing variations in phytoplankton populations. We demonstrate the design and fabrication of a Microflow Cytometer for characterization of phytoplankton. Guided by chevron-shaped grooves on the top and bottom of a microfluidic channel, two symmetric sheath streams wrap around a central sample stream and hydrodynamically focus it in the center of the channel. The lasers are carefully chosen to provide excitation light close to the maximum absorbance wavelengths for the intrinsic fluorophores chlorophyll and phycoerythrin, and the excitation light is coupled to the flow cytometer through the use of an optical fiber. Fluorescence and light scatter are collected using two multimode optical fibers placed at 90-degree angles with respect to the excitation fiber. Light emerging from these collection fibers is directed through optical bandpass filters into photomultiplier tubes. The cytometer measured the optical and side scatter properties of Karenia b., Synechococcus sp., Pseudo-Nitzchia, and Alexandrium. The effect of the sheath-to-sample flow-rate ratio on the light scatter and fluorescence of these marine microorganisms was investigated. Reducing the sample flow rate from 200 μL/min to 10 μL/min produced a more tightly focused sample stream and less heterogeneous signals.  相似文献   

4.
We have designed, demonstrated, and characterized a simple, novel in-plane tunable optofluidic microlens. The microlens is realized by utilizing the interface properties between two different fluids: CaCl(2)solution and air. A constant contact angle of ~90° is the pivotal factor resulting in the outward bowing and convex shape of the CaCl(2) solution-air interface. The contact angle at the CaCl(2) solution-air interface is maintained by a flared structure in the polydimethylsiloxane channel. The resulting bowing interface, coupled with the refractive index difference between the two fluids, results in effective in-plane focusing. The versatility of such a design is confirmed by characterizing the intensity of a traced beam experimentally and comparing the observed focal points with those obtained via ray-tracing simulations. With the radius of curvature conveniently controlled via fluid injection, the resulting microlens has a readily tunable focal length. This ease of operation, outstandingly low fluid usage, large range tunable focal length, and in-plane focusing ability make this lens suitable for many potential lab-on-a-chip applications such as particle manipulation, flow cytometry, and in-plane optical trapping.  相似文献   

5.
Data transmission via optical fiber is a new discipline of communication theory. The principal difference from conventional baseband data transmission, which is characterized by a signal independent additive Gaussian noise, is the existence of a signal dependent shot noise.This paper presents a technique for estimating the error probability performance of digital systems with inter-symbol interference and signal dependent additive noise. For binary antipodal (±1) systems, the approximate upper bound to the error probability is twice the lower bound. Hence either can be taken as a good approximation to the actual error probability. The technique is then applied to a model of some promising optical data communication systems and a good approximation to the error probability is obtained. Some observations about the effect of various system parameters on the error probability and some numerical examples are presented.  相似文献   

6.
Gyro simulation is an important process of inertial navigation theory research, with the major difficulty being the stochastic error modeling. One commonly used stochastic model for a fiber optic gyro (FOG) is a Gaussian white (GW) noise plus a first order Markov process. The model parameters are usually obtained by using time series analysis methods or the Allan variance method through FOG static experiment. However, in a real life situation, a FOG may not be used. In this paper, a simulation method is proposed for estimating the stochastic errors of FOG. When using this method, the model parameters are set based on performance indicators, which are chosen as the angle random walk (ARW) and bias stability. During the research, the ARW and bias stability indicators of the GW noise and the first order Markov process are analyzed separately. Their analytical expressions are derived to reveal the relation between the model parameters and performance indicators. In order to verify the theory, a large number of simulations were carried out. The results show that the statistical performance indicators of the simulated signals are consistent with the theory. Furthermore, a simulation of a VG951 FOG is designed in this research. The Allan variance curve of the simulated signal is in agreement with the real one.  相似文献   

7.
光纤感测温预警系统是较不常见的消防探测系统,电厂消防是典型的工程,本文将两者结合形成一个典型设计。  相似文献   

8.
Song W  Psaltis D 《Biomicrofluidics》2011,5(4):44110-4411011
We present a novel image-based method to measure the on-chip microfluidic pressure and flow rate simultaneously by using the integrated optofluidic membrane interferometers (OMIs). The device was constructed with two layers of structured polydimethylsiloxane (PDMS) on a glass substrate by multilayer soft lithography. The OMI consists of a flexible air-gap optical cavity which upon illumination by monochromatic light generates interference patterns that depends on the pressure. These interference patterns were captured with a microscope and analyzed by computer based on a pattern recognition algorithm. Compared with the previous techniques for pressure sensing, this method offers several advantages including low cost, simple fabrication, large dynamic range, and high sensitivity. For pressure sensing, we demonstrate a dynamic range of 0-10 psi with an accuracy of ±2% of full scale. Since multiple OMIs can be integrated into a single chip for detecting pressures at multiple locations simultaneously, we also demonstrated a microfluidic flow sensing by measuring the differential pressure along a channel. Thanks to the simple fabrication that is compatible with normal microfluidics, such OMIs can be easily integrated into other microfluidic systems for in situ fluid monitoring.  相似文献   

9.
10.
The steady two-dimensional stagnation point flow toward a stretching/shrinking sheet with the bottom surface of the sheet heated by convection from a hot fluid is considered. The governing partial differential equations are transformed into ordinary differential equations, before being solved numerically. Results for the skin friction coefficient and the local Nusselt number as well as the temperature profiles are presented for different values of the governing parameters. Effects of the governing parameters on the heat transfer characteristics are thoroughly examined. Different from a stretching sheet, it is found that the solutions for a shrinking sheet are non-unique.  相似文献   

11.
12.
13.
14.
Rapid concentration and detection of bacteria in integrated chips and microfluidic devices is needed for the advancement of lab-on-a-chip devices because current detection methods require high concentrations of bacteria which render them impractical. We present a new chip-scale rapid bacteria concentration technique combined with surface-enhanced Raman scattering (SERS) to enhance the detection of low bacteria count samples. This concentration technique relies on convection by a long-range converging vortex to concentrate the bacteria into a packed mound of 200 μm in diameter within 15 min. Concentration of bioparticle samples as low as 104 colony forming units (CFU)∕ml are presented using batch volumes as large as 150 μl. Mixtures of silver nanoparticles with Saccharomyces cerevisiae, Escherichia coli F-amp, and Bacillus subtilis produce distinct and noticeably different Raman spectra, illustrating that this technique can be used as a detection and identification tool.  相似文献   

15.
一种高阶平滑表面并行提取方法   总被引:1,自引:0,他引:1  
针对高阶平滑表面算法计算复杂和数据量大的问题,提出一种加快高阶平滑表面算法速度的并行方法.首先对高阶平滑表面算法进行并行化,然后采用优化技术提高算法性能,同时采用矩阵压缩改善内存空间性能.实验表明,在双核处理器上平均加速比达到1.87.  相似文献   

16.
This paper presents a convenient strategy to modify the surface of whole-Teflon microfluidic chips by coating the channel walls with a thin layer of polydopamine (PDA) film, which is formed by oxidation-induced self-polymerization of dopamine in alkaline solution. Two coating strategies, static incubation and dynamic flow, are demonstrated and used for tuning the physical and chemical properties of the coated channel walls. The functionalized surfaces were investigated with the contact angle, X-ray photoelectron spectroscopy, and atomic force microscopy measurements. The coating time was optimized according to the fluorescent intensity of the green fluorescent protein immobilized on the modified surface. Applications of the PDA-modified Teflon microchips in bioanalysis were demonstrated with a typical sandwich immunoassay. Moreover, long-term cell culture experiments on modified and native Teflon chips revealed that the chip biocompatibility can be greatly improved with PDA coating. The results indicate that the surface properties of the Teflon can be easily controlled by the PDA modification, thus greatly expanding the application scope of whole-Teflon chips for various chemical and biological research fields.  相似文献   

17.
We developed an automated laser induced fluorescence system utilizing microfluidic chips for detection and quantification of immunoglobulins. Microchips were fabricated from polydimethysiloxane (PDMS) using the so-called "prepolymerization technique." The microchip structure helped minimize the effects of PDMS autofluorescence and light scattering. Furthermore, a thin and uniform PDMS layer forming the top of the microchip enabled proper focusing and collection of the excitation beam and the emitted fluorescence, respectively. The developed system was tested for the detection of mouse immunoglobulins. The capturing antibodies were immobilized on internal microchannel walls in the form of a polyelectrolyte. We clearly show that this immobilization technique, if correctly realized, gives results with high reproducibility. After sample incubation and washing, secondary antibodies labeled by fluorescein isothiocyanate were introduced into microchannels to build a detectable complex. We show that mouse antibodies can be quantified in a wide concentration range, 0.01-100 μg ml(-1). The lower detection limit was below 0.001 μg ml(-1) (6.7 pM). The developed laser induced fluorescence (LIF) apparatus is relatively cheap and easy to construct. The total cost of the developed LIF detector is lower than a typical price of plate readers. If compared to classical ELISA (enzyme linked immunosorbent assay) plate systems, the detection of immunoglobulins or other proteins in the developed PDMS microfluidic device brings other important benefits such as reduced time demands (10 min incubation) and low reagent consumption (less than 1 μl). The cost of the developed PDMS chips is comparable with the price of commercial ELISA plates. The main troubleshooting related to the apparatus development is also discussed in order to help potential constructors.  相似文献   

18.
In this study, microneedles which possess sharp tips were utilized to trap and detect the biomolecules. Owing to the large curvature, the tips of the microneedles created a substantially high gradient of electric field under the non-uniform electric field which served as not only the trapping sites but also the substrate for surface enhanced Raman scattering (SERS). Separation of polystyrene microparticles with different sizes and two kinds of biomolecules (Staphylococcus aureus (S. aureus) and the red blood cells (RBCs)) were demonstrated. Moreover, in situ detection of S. aureus was performed immediately after separation was completed. The results showed that, after 15 s of sample collection, the Raman signals of S. aureus were detected and greatly enhanced through SERS effect.  相似文献   

19.
20.
The efficient manipulation of low-volume droplets offers many potential applications in relation to chemical and biomedical tests and protocols. A novel approach to the manipulation of a microdroplet on a superhydrophobic surface is introduced in the present communication. The microdroplet was first picked up onto a hydrophilic needle, transported from one location to another, and finally released under the action of an electric field force. Three key parameters in this process, the radius of the droplet, the distance between the two electrodes, and the required voltage, were investigated. This study should be helpful for the design of microfluidic devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号