首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
We introduce a new model for contact angle saturation phenomenon in electrowetting on dielectric systems. This new model attributes contact angle saturation to repulsion between trapped charges on the cap and base surfaces of the droplet in the vicinity of the three-phase contact line, which prevents these surfaces from converging during contact angle reduction. This repulsion-based saturation is similar to repulsion between charges accumulated on the surfaces of conducting droplets which causes the well known Coulombic fission and Taylor cone formation phenomena. In our model, both the droplet and dielectric coating were treated as lossy dielectric media (i.e., having finite electrical conductivities and permittivities) contrary to the more common assumption of a perfectly conducting droplet and perfectly insulating dielectric. We used theoretical analysis and numerical simulations to find actual charge distribution on droplet surface, calculate repulsion energy, and minimize energy of the total system as a function of droplet contact angle. Resulting saturation curves were in good agreement with previously reported experimental results. We used this proposed model to predict effect of changing liquid properties, such as electrical conductivity, and system parameters, such as thickness of the dielectric layer, on the saturation angle, which also matched experimental results.  相似文献   

2.
A new method is demonstrated to transport particles, cells, and other microorganisms using rectified ac electro-osmotic flows in open microchannels. The rectified flow is obtained by synchronous zeta potential modulation with the driving potential in the microchannel. Experiments were conducted to transport both neutral, charged particles, and microorganisms of various sizes. A maximum speed of 50 μm∕s was obtained for 8 μm polystyrene beads, without any electrolysis, using a symmetrical square waveform driving electric field of 5 V∕mm at 10 Hz and a 360 V gate potential with its polarity synchronized with the driving potential (phase lag=0°).  相似文献   

3.
Electrowetting with alternate voltage (AC) creates azimuthal flow vortices inside sessile droplets. These flow vortices can be controlled by introducing pinning sites at the contact line. When the frequency of the applied AC voltage is gradually ramped from a few hundreds of hertz to a few tens of kilohertz the azimuthal flow vortices contract and move towards the contact line near the pinning site. Dispersed particles in the liquid are collected in the center of these vortices leading to an increase in the local particle concentration by up to more than one order of magnitude. We provide a qualitative explanation for symmetry of the flow patterns within the drops and discuss possible scenarios explaining the particle collection and preconcentration.  相似文献   

4.
A novel microstirring strategy is applied to accelerate the digestion rate of the substrate Nα-benzoyl-L-arginine-4-nitroanilide (L-BAPA) catalyzed by sol-gel encapsulated trypsin. We use an ac nonlinear electrokinetic vortex flow to stir the solution in a microfluidic reaction chamber to reduce the diffusion length between the immobilized enzyme and substrate in the solution. High-intensity nonlinear electroosmotic microvortices, with angular speeds in excess of 1 cm∕s, are generated around a small (∼1.2 mm) conductive ion exchange granule when ac electric fields (133 V∕cm) are applied across a miniature chamber smaller than 10 μl. Coupling between these microvortices and the on-and-off electrophoretic motion of the granule in low frequency (0.1 Hz) ac fields produces chaotic stream lines to stir substrate molecules sufficiently. We demonstrate that, within a 5-min digestion period, the catalytic reaction rate of immobilized trypsin increases almost 30-fold with adequate reproducibility (15%) due to sufficient stirring action through the introduction of the nonlinear electrokinetic vortices. In contrast, low-frequency ac electroosmotic flow without the granule, provides limited stirring action and increases the reaction rate approximately ninefold with barely acceptable reproducibility (30%). Dye molecules are used to characterize the increases in solute diffusivity in the reaction reservoir in which sol-gel particles are placed, with and without the presence of granule, and compared with the static case. The solute diffusivity enhancement data show respective increases of ∼30 and ∼8 times, with and without the presence of granule. These numbers are consistent with the ratios of the enhanced reaction rate.  相似文献   

5.
Microfluidic blood plasma separation via bulk electrohydrodynamic flows   总被引:1,自引:0,他引:1  
An effective mechanism for rapid and efficient microfluidic particle trapping and concentration is proposed without requiring any mechanically moving parts. When a voltage beyond the threshold atmospheric ionization value is applied on a sharp electrode tip mounted at an angle above a microfluidic liquid chamber, the bulk electrohydrodynamic air thrust that is generated results in interfacial shear and, hence, primary azimuthal liquid surface recirculation. This discharge driven vortex mechanism, in turn, causes a secondary bulk meridional liquid recirculation, which produces an inward radial force near the bottom of the chamber. Particles suspended in the liquid are then rapidly convected by the bulk recirculation toward the bottom, where the inward radial force causes them to spiral in a helical swirl-like fashion toward a stagnation point. In particular, we show that these flows, similar to Batchelor flows occurring in a cylindrical liquid column between a stationary and rotating disk, can be used for the separation of red blood cells from blood plasma in a miniaturized device.  相似文献   

6.
We experimentally demonstrate that addition of small, charge-neutral polymers to a buffer solution can promote compression of dilute solutions of single electrophoresing DNA. This phenomenon contrasts with the observed extension of DNA during capillary electrophoresis in dilute solutions of high molecular weight polymers. We propose these discrepancies in micron-scale DNA configurations arise from different nano-scale DNA-polymer collision events, controlled by solute polymer properties. We build upon theories previously proposed for intermolecular DNA aggregation in polymer-free solutions to develop scaling theories that describe trends seen in our data for intramolecular DNA compaction in dilute polymer solutions.  相似文献   

7.
Li Y  Fu YQ  Brodie SD  Alghane M  Walton AJ 《Biomicrofluidics》2012,6(1):12812-128129
This paper presents integrated microfluidic lab-on-a-chip technology combining surface acoustic wave (SAW) and electro-wetting on dielectric (EWOD). This combination has been designed to provide enhanced microfluidic functionality and the integrated devices have been fabricated using a single mask lithographic process. The integrated technology uses EWOD to guide and precisely position microdroplets which can then be actuated by SAW devices for particle concentration, acoustic streaming, mixing and ejection, as well as for sensing using a shear-horizontal wave SAW device. A SAW induced force has also been employed to enhance the EWOD droplet splitting function.  相似文献   

8.
This paper investigates the phenomenon of Faradaic charging in ac electrokinetics. Faradaic reactions were suggested as a key effect responsible for the reversal of pumping direction in ac micropumps. However, this hypothesis has yet to be proven convincingly and directly. Here we present an ion detection strategy to determine the production of ions through Faradaic hydrolytic reactions originating from direct application of voltage to electrolytic solutions during ac electrokinetics. Experiments were performed with symmetrical planar electrodes aligned along a microfluidic channel. Fluorescein, a pH-dependent dye, was employed as the pH indicator for the detection of ion production. Images were captured for analysis at various voltage levels. From analyzing the fluorescence intensity and its distribution, it can be concluded that the production of ions from hydrolytic reactions takes place and increases with the ac voltage. The coefficient of deviation indicates a significant enhancement at ac voltage above 11 Vpp. Lastly, we demonstrate a strategy using dc-biased ac electrokinetics to achieve controllability in direction and magnitude of the net fluid flow in pumping application.  相似文献   

9.
The operation of digital microfluidic devices with water droplets manipulated by electrowetting is critically dependent on the static and dynamic stability and lubrication properties of the oil films that separate the droplets from the solid surfaces. The factors determining the stability of the films and preventing surface fouling in such systems are not yet thoroughly understood and were experimentally investigated in this study. The experiments were performed using a standard digital microfluidic cartridge in which water droplets enclosed in a thin, oil-filled gap were transported over an array of electrodes. Stable, continuous oil films separated the droplets from the surfaces when the droplets were stationary. During droplet transport, capillary waves formed in the films on the electrode surfaces as the oil menisci receded. The waves evolved into dome-shaped oil lenses. Droplet deformation and oil displacement caused the films at the surface opposite the electrode array to transform into dimples of oil trapped over the centers of the droplets. Lower actuation voltages were associated with slower film thinning and formation of fewer, but larger, oil lenses. Lower ac frequencies induced oscillations in the droplets that caused the films to rupture. Films were also destabilized by addition of surfactants to the oil or droplet phases. Such a comprehensive understanding of the oil film behavior will enable more robust electrowetting-actuated lab-on-a-chip devices through prevention of loss of species from droplets and contamination of surfaces at points where films may break.  相似文献   

10.
In a droplet transport based on electrowetting on dielectrics, the parallel-plate configuration is more popular than the single-plate one because the droplet transport becomes increasingly difficult without cover plate. In spite of the improved transport performance, the parallel-plate configuration often limits the access to the peripheral components, requesting the removal of the cover plate, the single-plate configuration. We investigated the fundamental features of droplet transport for the single-plate configuration. We compared the performance of several switching methods with respect to maximum speed of successive transport without failure and suggested nonfloating switching method which is inherently free from the charge-residue problem and exerts greater force on a droplet than conventional switching methods. A simple theory is provided to understand the different results for the switching methods.  相似文献   

11.
Electroosmotic (EO) pumps based on dc electroosmosis is plagued by bubble generation and other electrochemical reactions at the electrodes at voltages beyond 1 V for electrolytes. These disadvantages limit their throughput and offset their portability advantage over mechanical syringe or pneumatic pumps. ac electroosmotic pumps at high frequency (>100 kHz) circumvent the bubble problem by inducing polarization and slip velocity on embedded electrodes,1 but they require complex electrode designs to produce a net flow. We report a new high-throughput ac EO pump design based on induced-polarization on the entire channel surface instead of just on the electrodes. Like dc EO pumps, our pump electrodes are outside of the load section and form a cm-long pump unit consisting of three circular reservoirs (3 mm in diameter) connected by a 1×1 mm channel. The field-induced polarization can produce an effective Zeta potential exceeding 1 V and an ac slip velocity estimated as 1 mm∕sec or higher, both one order of magnitude higher than earlier dc and ac pumps, giving rise to a maximum throughput of 1 μl∕sec. Polarization over the entire channel surface, quadratic scaling with respect to the field and high voltage at high frequency without electrode bubble generation are the reasons why the current pump is superior to earlier dc and ac EO pumps.  相似文献   

12.
The motion of a droplet from one electrode to the next in electrowetting on dielectric microsystems is not straightforward. Microfabrication imposes a gap separating the electrodes. This hydrophobic gap has the effect of pinning the triple contact line, preventing the motion of the microdrop. To avoid such a drawback, jagged electrodes, i.e., electrodes with crenellated side boundaries have been designed. In this work, an analytical model for dimensioning the size of the dents of the electrodes is derived based on the contact line elasticity theory. This model determines a lower limit for the nondimensional ratio of the length of a dent to its width. The designs of jagged electrodes in the literature have been verified to satisfy the condition, but with very different safety margins.  相似文献   

13.
We present design, characterization, and testing of an inexpensive, sheath-flow based microfluidic device for three-dimensional (3D) hydrodynamic focusing of cells in imaging flow cytometry. In contrast to other 3D sheathing devices, our device hydrodynamically focuses the cells in a single-file near the bottom wall of the microchannel that allows imaging cells with high magnification and low working distance objectives, without the need for small device dimensions. The relatively large dimensions of the microchannels enable easy fabrication using less-precise fabrication techniques, and the simplicity of the device design avoids the need for tedious alignment of various layers. We have characterized the performance of the device with 3D numerical simulations and validated these simulations with experiments of hydrodynamic focusing of a fluorescently dyed sample fluid. The simulations show that the width and the height of the 3D focused sample stream can be controlled independently by varying the heights of main and side channels of the device, and the flow rates of sample and sheath fluids. Based on simulations, we also provide useful guidelines for choosing the device dimensions and flow rates for focusing cells of a particular size. Thereafter, we demonstrate the applicability of our device for imaging a large number of RBCs using brightfield microscopy. We also discuss the choice of the region of interest and camera frame rate so as to image each cell individually in our device. The design of our microfluidic device makes it equally applicable for imaging cells of different sizes using various other imaging techniques such as phase-contrast and fluorescence microscopy.  相似文献   

14.
In this work we report a microfluidic platform capable of trapping and concentrating a trace amount of DNA molecules efficiently. Our strategy invokes nonlinear electro-osmotic flow induced by charge polarization under high-frequency ac fields. With the asymmetric quadrupole electrode design, a unique converging flow structure can be created for generating focusing effects on DNA molecules. This focusing in turn transforms into a robust funnel that can collect DNA molecules distantly from the bulk and pack them into a compact cone with the aid of short-range dipole-induced self-attraction and dielectrophoresis. Our results reveal that not only can DNA molecules be concentrated within just a few seconds, but also they can be focused into threads of 1 mm in length, demonstrating the superfast and long-range trapping capability of this funnel. In addition, pico M DNA solutions can be concentrated with several decades of enhancement without any continuous feeding. Alternating concentration and release of DNA molecules is also illustrated, which has potentials in concentrating and transporting biomolecules in a continuous fashion using microdevices.  相似文献   

15.
Three dimensional (3D) stepped electrodes dramatically improve the flow rate and frequency range of ac electro-osmotic pumps, compared to planar electrodes. However, the fabrication of 3D stepped electrodes for ac electro-osmosis (ACEO) pumps usually involves several processing steps. This paper demonstrates results from ACEO pumps produced by a faster and less expensive method to fabricate the 3D electrodes—extending the previous work to disposable devices. The method is based on shadowed evaporation of metal on an insulating substrate that can be injection molded. Flow velocities through the 3D ACEO pump are similar to those seen in the previous work.  相似文献   

16.
Orthogonal electrodes have been reported to produce high velocity microflows when excited by ac signals, showing potential for micropumping applications. This paper investigates the microflow reversal phenomena in such orthogonal electrode micropumps. Three types of microflow fields were observed by changing the applied electric signals. Three ac electrokinetic processes, capacitive electrode polarization, Faradaic polarization, and the ac electrothermal effect, are proposed to explain the different flow patterns, respectively. The hypotheses were corroborated by impedance analysis, numerical simulations, and velocity measurements. The investigation of microflow reversal can improve the understanding of ac electrokinetics and hence effectively manipulate fluids.  相似文献   

17.
齐振宏 《科研管理》2006,27(4):155-159,141
传统的职能组织因部门界限和官僚主义等导致了帕勒摩定律,这种"部门裂缝"的最大危害突出表现在怠慢顾客、组织效率低下,这与今天市场需要的迅速、动态、灵活、优质的客户需求是背道而驰的;文中对联想集团不良价值流、产生原因及再造价值流进行了实证分析,指出了走出帕勒摩定律困境、再造价值流的措施与对策。  相似文献   

18.
19.
In this work, invoking join asymmetric ac polarization using double half-quadrupole electrodes in a symmetric arrangement, we demonstrate a head-on ac electro-osmotic streaming capable of focusing and trapping DNA molecules efficiently. This is manifested by the observation that picomolar DNA molecules can be trapped into a large crosslike spot with at least an order of magnitude concentration enhancement within just half a minute. We identify that the phenomenon is a combined result of the formation of two prefocused DNA jets flowing toward each other, dipole-induced attraction between focused DNA molecules, and dielectrophoretic trap on the spot. With an additional horizontal pumping, we observe that the trap can transform into a peculiar pitchfork streaming capable of continuous collection and long-distance transport of concentrated DNA molecules. We also show that the same electrode design can be used to direct assembly of submicrometer particles. This newly designed microfluidic platform not only has potentials in enhancing detection sensitivity and facilitating functional assembly for on-chip analysis but also provides an added advantage of transporting target molecules in a focused and continuous manner.  相似文献   

20.
In this work, we demonstrate an integrated, single-layer, miniature flow cytometry device that is capable of multi-parametric particle analysis. The device integrates both particle focusing and detection components on-chip, including a "microfluidic drifting" based three-dimensional (3D) hydrodynamic focusing component and a series of optical fibers integrated into the microfluidic architecture to facilitate on-chip detection. With this design, multiple optical signals (i.e., forward scatter, side scatter, and fluorescence) from individual particles can be simultaneously detected. Experimental results indicate that the performance of our flow cytometry chip is comparable to its bulky, expensive desktop counterpart. The integration of on-chip 3D particle focusing with on-chip multi-parametric optical detection in a single-layer, mass-producible microfluidic device presents a major step towards low-cost flow cytometry chips for point-of-care clinical diagnostics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号