首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
ABSTRACT

The aim of the present investigation was to analyze the validity and reliability of a novel iPhone app (CODTimer) for the measurement of total time and interlimb asymmetry in the 5 + 5 change of direction test (COD). To do so, twenty physically active adolescent athletes (age = 13.85 ± 1.34 years) performed six repetitions in the COD test while being measured with a pair of timing gates and CODTimer. A total of 120 COD times measured both with the timing gates and the app were then compared for validity and reliability purposes. There was an almost perfect correlation between the timing gates and the CODTimer app for the measurement of total time (r = 0.964; 95% Confidence interval (CI) = 0.95–1.00; Standard error of the estimate = 0.03 s.; p < 0.001). Moreover, non-significant, trivial differences were observed between devices for the measurement of total time and interlimb asymmetry (Effect size < 0.2, p > 0.05). Similar levels of reliability were observed between the timing gates and the app for the measurement of the 6 different trials of each participant (Timing gates: Intraclass correlation coefficient (ICC) = 0.651–0.747, Coefficient of variation (CV) = 2.6–3.5%; CODTimer: ICC = 0.671–0.840, CV = 2.2–3.2%). The results of the present study show that change of direction performance can be measured in a valid, reliable way using a novel iPhone app.  相似文献   

2.
The purpose of this investigation was to analyse the concurrent validity and reliability of an iPhone app (called: My Jump) for measuring vertical jump performance. Twenty recreationally active healthy men (age: 22.1 ± 3.6 years) completed five maximal countermovement jumps, which were evaluated using a force platform (time in the air method) and a specially designed iPhone app. My jump was developed to calculate the jump height from flight time using the high-speed video recording facility on the iPhone 5 s. Jump heights of the 100 jumps measured, for both devices, were compared using the intraclass correlation coefficient, Pearson product moment correlation coefficient (r), Cronbach’s alpha (α), coefficient of variation and Bland–Altman plots. There was almost perfect agreement between the force platform and My Jump for the countermovement jump height (intraclass correlation coefficient = 0.997, P < 0.001; Bland–Altman bias = 1.1 ± 0.5 cm, P < 0.001). In comparison with the force platform, My Jump showed good validity for the CMJ height (= 0.995, P < 0.001). The results of the present study showed that CMJ height can be easily, accurately and reliably evaluated using a specially developed iPhone 5 s app.  相似文献   

3.
The purpose of this study was to analyse the validity and reliability of a novel iPhone app (named: PowerLift) for the measurement of mean velocity on the bench-press exercise. Additionally, the accuracy of the estimation of the 1-Repetition maximum (1RM) using the load–velocity relationship was tested. To do this, 10 powerlifters (Mean (SD): age = 26.5 ± 6.5 years; bench press 1RM · kg?1 = 1.34 ± 0.25) completed an incremental test on the bench-press exercise with 5 different loads (75–100% 1RM), while the mean velocity of the barbell was registered using a linear transducer (LT) and Powerlift. Results showed a very high correlation between the LT and the app (r = 0.94, SEE = 0.028 m · s?1) for the measurement of mean velocity. Bland–Altman plots (R2 = 0.011) and intraclass correlation coefficient (ICC = 0.965) revealed a very high agreement between both devices. A systematic bias by which the app registered slightly higher values than the LT (P < 0.05; mean difference (SD) between instruments = 0.008 ± 0.03 m · s?1). Finally, actual and estimated 1RM using the app were highly correlated (r = 0.98, mean difference (SD) = 5.5 ± 9.6 kg, P < 0.05). The app was found to be highly valid and reliable in comparison with a LT. These findings could have valuable practical applications for strength and conditioning coaches who wish to measure barbell velocity in the bench-press exercise.  相似文献   

4.
The purpose of this study was to assess validity and reliability of sprint performance outcomes measured with an iPhone application (named: MySprint) and existing field methods (i.e. timing photocells and radar gun). To do this, 12 highly trained male sprinters performed 6 maximal 40-m sprints during a single session which were simultaneously timed using 7 pairs of timing photocells, a radar gun and a newly developed iPhone app based on high-speed video recording. Several split times as well as mechanical outputs computed from the model proposed by Samozino et al. [(2015). A simple method for measuring power, force, velocity properties, and mechanical effectiveness in sprint running. Scandinavian Journal of Medicine & Science in Sports. https://doi.org/10.1111/sms.12490] were then measured by each system, and values were compared for validity and reliability purposes. First, there was an almost perfect correlation between the values of time for each split of the 40-m sprint measured with MySprint and the timing photocells (r?=?0.989–0.999, standard error of estimate?=?0.007–0.015?s, intraclass correlation coefficient (ICC)?=?1.0). Second, almost perfect associations were observed for the maximal theoretical horizontal force (F0), the maximal theoretical velocity (V0), the maximal power (Pmax) and the mechanical effectiveness (DRF – decrease in the ratio of force over acceleration) measured with the app and the radar gun (r?=?0.974–0.999, ICC?=?0.987–1.00). Finally, when analysing the performance outputs of the six different sprints of each athlete, almost identical levels of reliability were observed as revealed by the coefficient of variation (MySprint: CV?=?0.027–0.14%; reference systems: CV?=?0.028–0.11%). Results on the present study showed that sprint performance can be evaluated in a valid and reliable way using a novel iPhone app.  相似文献   

5.
This study aimed to assess the reliability, usefulness and construct validity of the newly developed Combined Basketball Skill Test (CBST). Fifteen recreational (age = 22.8 ± 4.2 y, stature = 184.8 ± 6.5 cm, body mass = 81.6 ± 9.6 kg, training experience = 9.8 ± 5.3 y) and fifteen semiprofessional (age = 18.9 ± 3.3 y, stature = 190.5 ± 8.1 cm, body mass = 84.2 ± 11.2 kg, training experience = 11.1 ± 3.5 y) players volunteered to participate in this study. Test–retest reliability and usefulness were examined for recreational players, while construct validity was evaluated comparing the two player groups. The CBST is composed of 12 trials and its outcome measures include: completion time (sum of the 12 trial times); penalty time (sum of the times from the 12 trials); performance time (completion time + penalty time) and total number of errors. Relative reliability analysis showed acceptable ICC values (i.e. ≥0.70) in all the studied variables. Absolute reliability analysis showed a CV < 5% for completion (1.6%) and performance (2.0%) time, while a CV >5% is reported for the remaining variables. The usefulness of the test was considered “Marginal” and “Good” when comparing TE values with SWC02 and SWC05, respectively for all the studied variables. Likely and very likely differences were shown between recreational and semiprofessional players in all investigated variables. Results showed that the CBST is reliable, useful to detect moderate changes and valid to assess basketball skills.  相似文献   

6.
研究背景:现有研究文献尚无有关在着地过程中不同表面倾斜度和踝关节护具效应的运动学、动力学和地面反作用力的综合数据。通过对比25°斜面和平面的着地以及使用和不使用踝关节护具情况下来检测踝关节的生物力学特性。研究方法: 11名健康受试者[年龄:(24.6±3.5)岁,身高:(24.6±0.10)m,质量:(65.6±14.9)kg)参与本次研究。受试者在4个动态运动条件下各进行5五次实验:从0.45米高处垂直下落至25°的斜面(IS)或平面(FS)上,使用或不使用半刚性踝关节护具,同时采集三维运动学和测力台地面反作用力数据。利用2×2(表面X踝关节护具)的重复测量方差分析来评估选定的变量。研究结果:与平面着地相比,斜面着地造成较小的垂直和内侧地面反作用力峰值。研究还发现踝关节背曲运动范围、着地角度和背曲速度、最大外翻与跖曲角速度提高,但产生了更大内翻角度和运动范围、着地内翻速度和最大跖曲力矩。踝关节护具在斜面着地时减少了达到地面反作用力第二垂直峰值的时间、着地角度、背曲速度、最大外翻和跖曲速度,但增加了跖曲力矩的最大值。研究结论:斜面增加踝关节额状面的运动范围和踝关节负荷。但是,就斜面着地而言,踝关节护具对踝关节额状面的运动范围和踝关节负荷的影响是相当有限的。  相似文献   

7.
Abstract

The purpose of this study was to investigate changes in ankle joint stiffness and the associated changes in the gastrocnemius muscle and tendon due to static stretching. Seven healthy male participants lay supine with the hip and knee joints fully extended. The right ankle joint was rotated into dorsiflexion from a 30° plantar flexed position and the torque measured by a dynamometer. The ankle joint was maintained in a dorsiflexed position for 20 min (static stretching of the calf muscles). We performed surface electromyography of the medial and lateral gastrocnemii, the soleus, and the tibialis anterior of the right leg to confirm no muscle activity throughout static stretching and the passive test (passive dorsiflexion). During static stretching, the ankle joint angle and elongation of the gastrocnemius were recorded by goniometry and ultrasonography, respectively. Tendon elongation of the gastrocnemius was calculated based on the changes in the ankle joint angle and muscle elongation. In addition, the relationships between passive torques and ankle joint angles, and elongation of muscle and tendon, were examined before and after static stretching. The ankle dorsiflexion angle and tendon elongation increased significantly by 10 min after the onset of static stretching, while there was no further increase in muscle length. In addition, ankle dorsiflexion angle and tendon elongation at an identical passive torque (30 N · m) increased significantly (from 24±7° to 33±5° and from 17±2 mm to 22±1 mm, respectively) after static stretching. However, muscle elongation was unchanged. In conclusion, the current results suggest that an increase in the ankle joint dorsiflexion angle due to static stretching is attributable to a change in tendon not muscle stiffness.  相似文献   

8.
There has been no previous investigation of the concurrent validity and reliability of the current 5 Hz global positioning system (GPS) to assess sprinting speed or the reliability of integrated GPS-accelerometer technology. In the present study, we wished to determine: (1) the concurrent validity and reliability of a GPS and timing gates to measure sprinting speed or distance, and (2) the reliability of proper accelerations recorded via GPS-accelerometer integration. Nineteen elite youth rugby league players performed two over-ground sprints and were simultaneously assessed using GPS and timing gates. The GPS measurements systematically underestimated both distance and timing gate speed. The GPS measurements were reliable for all variables of distance and speed (coefficient of variation [CV] = 1.62% to 2.3%), particularly peak speed (95% limits of agreement [LOA] = 0.00 ± 0.8 km · h(-1); CV = 0.78%). Timing gates were more reliable (CV = 1% to 1.54%) than equivalent GPS measurements. Accelerometer measurements were least reliable (CV = 4.69% to 5.16%), particularly for the frequency of proper accelerations (95% LOA = 1.00 ± 5.43; CV = 14.12%). Timing gates and GPS were found to reliably assess speed and distance, although the validity of the GPS remains questionable. The error found in accelerometer measurements indicates the limits of this device for detecting changes in performance.  相似文献   

9.
ABSTRACT

Anaerobic performance in youth has received little attention partly due to the lack of a “gold-standard” measurement. However, force-velocity-power (F-v-P) profiling recently showed high reliability and validity in trained adults. Therefore, the aim was to determine the reliability of F-v-P profiling in children and adolescents. Seventy-five children (60 boys, 15 girls; age: 14.1 ± 2.6 years) completed three 30 m sprints. Velocity was measured at 46.875 Hz using a radar device. The F-v-P profile was fitted to a velocity-time curve allowing instantaneous power variables to be calculated. Reliability was assessed using the intra-class correlation coefficient (ICC), coefficient of variation (CV), standard error of measurement (SEM) and smallest worthwhile change (SWC). High reliability was evident for absolute peak (Ppeak) and mean power (Pmean), Ppeak and Pmean expressed relative to body mass, peak and mean velocity, 30 m sprint time, peak horizontal force (F0), relative F0, mechanical efficiency index and fatigue rate (ICC: 0.75–0.88; CV: 1.9–9.4%) with time to peak power demonstrating moderate reliability (ICC: 0.50; CV: 9.5%). The F-v-P model demonstrated at least moderate reliability for all variables. This therefore provides a potential alternative for paediatric researchers assessing sprint performance and the underlying kinetics.  相似文献   

10.
ABSTRACT

The aim of this investigation was to assess the reliability and validity of the Fitjump system. Fifty-seven participants (age = 22.62 ± 5.24 years, height = 180.69 ± 12.53 cm, body mass = 75.61 ± 9.56 kg) performed three countermovement jump (CMJ) and squat jump (SJ) with a 1-week interval for test and retest reliability. For validity, the participants performed the same jump protocol on the force platform while being simultaneously measured with the Fitjump system. There was excellent test–retest reliability of the Fitjump system for CMJ and SJ with high intraclass correlation coefficient (ICCs) (0.97 and 0.97, respectively), low coefficient variation (CVs) (2.3% and 2.4%, respectively), and low typical error of estimate [(TEE (%)] (4.0% and 4.4%, respectively). For validity, ICCs were extremely high for CMJ and SJ (0.93 and 0.94, respectively), with low TEE (%) (2.9% and 2.0%, respectively). However, Fitjump overestimated jump height for CMJ and SJ (3.54 and 3.37 cm, respectively; p < 0.001) when compared with the force platform. As a conclusion, the Fitjump system demonstrated excellent test–retest reliability and high relationship with a systematic bias for validity. Therefore, the Fitjump system can be used as a portable tool for monitoring vertical jump changes over time, but it should not be used interchangeably with a force platform.  相似文献   

11.
Ballerinas use their ankle joints more extremely and sustain injuries on the ankle joint more frequently than non-dancers. Therefore, the ankle movement of dancers is important and should be studied to prevent injuries. Measuring ankle joint range of motion (ROM) using radiographs could demonstrate the contribution to motion of each joint. The aim of this study was to analyse and compare ankle joint movements and the ratio of each joint’s contribution during movement between dancers and non-dancers, using radiographic images. Dancers have lower dorsiflexion (26.7 ± 6.2°), higher plantarflexion (74.3 ± 7.1°) and higher total (101.1 ± 10.8°) ROMs than non-dancers (33.9 ± 7.0°, 57.2 ± 6.8° and 91.1 ± 9.3°, respectively) (p < 0.05). Although the ROMs were different between the two groups, the ratios of each joint movement were similar between these two groups, in all movements. Regarding total movement, the movement ratio of the talocrural joint was almost 70% and other joints accounted for almost 30% of the movement role in both dancers and non-dancers. Therefore, the differences in ROM between dancers and non-dancers were not a result of a specific joint movement but of all the relevant joints’ collaborative movement.  相似文献   

12.
Abstract

There has been no previous investigation of the concurrent validity and reliability of the current 5 Hz global positioning system (GPS) to assess sprinting speed or the reliability of integrated GPS–accelerometer technology. In the present study, we wished to determine: (1) the concurrent validity and reliability of a GPS and timing gates to measure sprinting speed or distance, and (2) the reliability of proper accelerations recorded via GPS–accelerometer integration. Nineteen elite youth rugby league players performed two over-ground sprints and were simultaneously assessed using GPS and timing gates. The GPS measurements systematically underestimated both distance and timing gate speed. The GPS measurements were reliable for all variables of distance and speed (coefficient of variation [CV] = 1.62% to 2.3%), particularly peak speed (95% limits of agreement [LOA] = 0.00 ± 0.8 km · h?1; CV = 0.78%). Timing gates were more reliable (CV = 1% to 1.54%) than equivalent GPS measurements. Accelerometer measurements were least reliable (CV = 4.69% to 5.16%), particularly for the frequency of proper accelerations (95% LOA = 1.00 ± 5.43; CV = 14.12%). Timing gates and GPS were found to reliably assess speed and distance, although the validity of the GPS remains questionable. The error found in accelerometer measurements indicates the limits of this device for detecting changes in performance.  相似文献   

13.
This study aimed to evaluate the test–retest reliability of a new device for assessing ankle joint kinesthesia. This device could measure the passive motion threshold of four ankle joint movements, namely plantarflexion, dorsiflexion, inversion and eversion. A total of 21 healthy adults, including 13 males and 8 females, participated in the study. Each participant completed two sessions on two separate days with 1-week interval. The sessions were administered by the same experimenter in the same laboratory. At least 12 trials (three successful trials in each of the four directions) were performed in each session. The mean values in each direction were calculated and analysed. The ICC values of test–retest reliability ranged from 0.737 (dorsiflexion) to 0.935 (eversion), whereas the SEM values ranged from 0.21° (plantarflexion) to 0.52° (inversion). The Bland–Altman plots showed that the reliability of plantarflexion–dorsiflexion was better than that of inversion–eversion. The results evaluated the reliability of the new device as fair to excellent. The new device for assessing kinesthesia could be used to examine the ankle joint kinesthesia.  相似文献   

14.
Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.  相似文献   

15.
BackgroundBalance impairment is one of the strongest risk factors for falls. Proprioception, cutaneous sensitivity, and muscle strength are 3 important contributors to balance control in older adults. The relationship that dynamic and static balance control has to proprioception, cutaneous sensitivity, and muscle strength is still unclear. This study was performed to investigate the relationship these contributors have to dynamic and static balance control.MethodsA total of 164 older adults (female = 89, left dominant = 15, age: 73.5 ± 7.8 years, height: 161.6 ± 7.1 cm, weight: 63.7 ± 8.9 kg, mean ± SD) participated in this study. It tested the proprioception of their knee flexion/extension and ankle dorsi/plantarflexion, along with cutaneous sensitivity at the great toe, first and fifth metatarsals, arch, and heel, and the muscle strength of their ankle dorsi/plantarflexion and hip abduction. The Berg Balance Scale (BBS) and the root mean square (RMS) of the center of pressure (CoP) were collected as indications of dynamic and static balance control. A partial correlation was used to determine the relationship between the measured outcomes variables (BBS and CoP-RMS) and the proprioception, cutaneous sensitivity, and muscle strength variables.ResultsProprioception of ankle plantarflexion (r = –0.306, p = 0.002) and dorsiflexion (r = –0.217, p = 0.030), and muscle strength of ankle plantarflexion (r = 0.275, p = 0.004), dorsiflexion (r = 0.369, p < 0.001), and hip abduction (r = 0.342, p < 0.001) were weakly to moderately correlated with BBS. Proprioception of ankle dorsiflexion (r = 0.218, p = 0.020) and cutaneous sensitivity at the great toe (r = 0.231, p = 0.041) and arch (r = 0.285, p = 0.002) were weakly correlated with CoP-RMS in the anteroposterior direction. Proprioception of ankle dorsiflexion (r = 0.220, p = 0.035), knee flexion (r = 0.308, p = 0.001) and extension (r = 0.193, p = 0.040), and cutaneous sensitivity at the arch (r = 0.206, p = 0.028) were weakly to moderately correlated with CoP-RMS in the mediolateral direction.ConclusionThere is a weak-to-moderate relationship between proprioception and dynamic and static balance control, a weak relationship between cutaneous sensitivity and static balance control, and a weak-to-moderate relationship between muscle strength and dynamic balance control.  相似文献   

16.
This study aimed to assess the validity and reliability of jump assessments using the MyJump2 application. Eleven junior athletes (15 ± 1.4 years) performed five countermovement (CMJ) and drop jumps (DJ) measured simultaneously by a force platform and MyJump2. Additionally, intra- and inter-day reliability was assessed over two sessions, 7 days apart. Extremely high agreement between MyJump2 and the force platform (intra-class correlation coefficient, ICC ≥ 0.99) and the intra- and inter-operator agreement (ICC = 0.98–0.99) confirmed the validity and reliability of MyJump2. Mean typical errors (coefficient of variation percentage, CV%) within the first and second sessions were 4.9% and 4.5% respectively for CMJs, and 8.0% to 11.8% for DJ outcomes. CMJ height held acceptable inter-day reliability (CV < 10%; ICC > 0.8), while DJ did not. Results supported MyJump2 to be a valid and reliable tool for assessing jumps; however, with variability in DJs in this cohort, appropriate caution should be taken if including in a junior assessment battery.  相似文献   

17.
Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73–0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.  相似文献   

18.
19.
Abstract

The aim of the present study was to investigate the kinematic and kinetic differences in the execution of vertical jumps between individuals with good and poor ankle dorsiflexion. Fifteen physical education students were assigned to the flexible group (FG), while another 15 were assigned to the inflexible group (IFG). The two groups executed countermovement jumps (CMJ) and drop jumps from a 60 cm height (DJ60). For the CMJ, the FG jumped higher (32.0 ± 4.0 cm vs. 30.2 ± 4.9 cm, P = 0.27) and used a greater range of motion in all leg joints. The IFG jumpers raised their heels off the ground and had a greater horizontal distance between the centre of mass of the trunk and the centre of the hip joint (LCMh 25.6 ± 3.4 cm vs. 30.9 ± 4.3 cm, P < 0.001). In the DJ60 the FG jumped higher (22.4 ± 5.9 cm vs. 19.5 ± 4.6 cm, P = 0.14) with a greater vertical shift of the body centre of mass (BCM) (S = 0.45 ± 0.11 cm vs. 0.36 ± 0.05 cm, P < 0.01) and better joint coordination. The IFG jumpers changed the position of their trunk and heels depending on the jump type. Trainers should reconsider the technical issues of vertical jumps according to the flexibility of the ankle joint.  相似文献   

20.
The aim of this study was to investigate the effects of strengthening and stretching exercises on running kinematics and kinetics in older runners. One hundred and five runners (55–75 years) were randomly assigned to either a strengthening (n = 36), flexibility (n = 34) or control (n = 35) group. Running kinematics and kinetics were obtained using an eight-camera system and an instrumented treadmill before and after the eight-week exercise protocol. Measures of strength and flexibility were also obtained using a dynamometer and inclinometer/goniometer. A time effect was observed for the excursion angles of the ankle sagittal (P = 0.004, d = 0.17) and thorax/pelvis transverse (P < 0.001, d = 0.20) plane. Similarly, a time effect was observed for knee transverse plane impulse (P = 0.013, d = 0.26) and ground reaction force propulsion (P = 0.042, d = ?0.15). A time effect for hip adduction (P = 0.006, d = 0.69), ankle dorsiflexion (P = 0.002, d = 0.47) and hip internal rotation (P = 0.048, d = 0.30) flexibility, and hip extensor (P = 0.001, d = ?0.48) and ankle plantar flexor (P = 0.01, d = 0.39) strength were also observed. However, these changes were irrespective of exercise group. The results of the present study indicate that an eight-week stretching or strengthening protocol, compared to controls, was not effective in altering age-related running biomechanics despite changes in ankle and trunk kinematics, knee kinetics and ground reaction forces along with alterations in muscle strength and flexibility were observed over time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号