首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
This study investigated the reliability of a wireless accelerometer and its agreement with optical motion capture for the measurement of root mean square (RMS) acceleration during running. RMS acceleration provides a whole-body metric of movement mechanics and economy. Fifteen healthy college-age participants performed treadmill running for two 60-s trials at 2.22, 2.78, and 3.33 m/s and one trial of 150 s (five 30-s epochs) at 2.78 m/s. We assessed between-trial and within-trial reliability, and agreement in each axis between a trunk-mounted wireless accelerometer and a reflective marker on the accelerometer measured by optical motion capture. Intraclass correlations assessing between-trial repeatability were 0.89–0.97, depending on the axis, and intraclass correlations assessing within-trial repeatability were 0.99–1.00. Bland–Altman analyses assessing agreement indicated mean difference values between ?0.03 and 0.03 g, depending on the axis. Anterio-posterior acceleration had the greatest limits of agreement (LOA) (±0.12 g) and vertical acceleration had the smallest LOA (±0.03 g). For measuring RMS acceleration of the trunk, this wireless accelerometer node provides repeatable and valid measurement compared with the standard laboratory method of optical motion capture.  相似文献   

2.
This study aimed to determine if a quantifiable relationship exists between the peak sound amplitude and peak vertical ground reaction force (vGRF) and vertical loading rate during running. It also investigated whether differences in peak sound amplitude, contact time, lower limb kinematics, kinetics and foot strike technique existed when participants were verbally instructed to run quietly compared to their normal running. A total of 26 males completed running trials for two sound conditions: normal running and quiet running. Simple linear regressions revealed no significant relationships between impact sound and peak vGRF in the normal and quiet conditions and vertical loading rate in the normal condition. t-Tests revealed significant within-subject decreases in peak sound, peak vGRF and vertical loading rate during the quiet compared to the normal running condition. During the normal running condition, 15.4% of participants utilised a non-rearfoot strike technique compared to 76.9% in the quiet condition, which was corroborated by an increased ankle plantarflexion angle at initial contact. This study demonstrated that quieter impact sound is not directly associated with a lower peak vGRF or vertical loading rate. However, given the instructions to run quietly, participants effectively reduced peak impact sound, peak vGRF and vertical loading rate.  相似文献   

3.
ABSTRACT

Running is a common exercise with numerous health benefits. Vertical ground reaction force (vGRF) influences running injury risk and running performance. Measurement of vGRF during running is now primarily constrained to a laboratory setting. The purpose of this study was to evaluate a new approach to measuring vGRF during running. This approach can be used outside of the laboratory and involves running shoes instrumented with novel piezoresponsive sensors and a standard accelerometer. Thirty-one individuals ran at three different speeds on a force-instrumented treadmill while wearing the instrumented running shoes. vGRF was predicted using data collected from the instrumented shoes, and predicted vGRF were compared to vGRF measured via the treadmill. Per cent error of the resulting predictions varied depending upon the predicted vGRF characteristic. Per cent error was relatively low for predicted vGRF impulse (2–7%), active peak vGRF (3–7%), and ground contact time (3–6%), but relatively high for predicted vGRF load rates (22–29%). These errors should decrease with future iterations of the instrumented shoes and collection of additional data from a more diverse sample. The novel technology described herein might become a feasible way to collect large amounts of vGRF data outside of the traditional biomechanics laboratory.  相似文献   

4.
Abstract

The purpose of the present study was to relate 3D acceleration patterns of the lower and upper trunk during running to running gait cycle, assess the validity of stride duration estimated from acceleration patterns, investigate speed-dependent changes in acceleration, and examine the test–retest reliability of these parameters. Thirteen healthy young men performed two running trials each on a treadmill and on land at three speeds (slow, preferred, and fast). The 3D accelerations were measured at the L3 spinous process (lower trunk) and the ensiform process (upper trunk) and synchronised with digital video data. The amplitude and root mean square of acceleration and stride duration were calculated and then analysed by three-way analysis of variance to test effects of running conditions, device location, and running speed. Bland-Altman analysis was used to evaluate the test–retest reliability. Marked changes in acceleration were observed in relation to foot strike during running. Stride durations calculated from the vertical accelerations were nearly equal to those estimated from video data. There were significant speed effects on all parameters, and the low test–retest reliability was confirmed in the anterior–posterior acceleration during treadmill running and the anterior–posterior acceleration at slow speed during treadmill and overground running.  相似文献   

5.
The aim of the present study was to examine reliability and construct convergent validity of Player Load? (PL) from trunk-mounted accelerometry, expressed as a cumulative measure and an intensity measure (PL · min1). Fifteen male participants twice performed an overground football match simulation that included four different multidirectional football actions (jog, side cut, stride and sprint) whilst wearing a trunk-mounted accelerometer inbuilt in a global positioning system unit. Results showed a moderate-to-high reliability as indicated by the intra-class correlation coefficient (0.806–0.949) and limits of agreement. Convergent validity analysis showed considerable between-participant variation (coefficient of variation range 14.5–24.5%), which was not explained from participant demographics despite a negative association with body height for the stride task. Between-task variations generally showed a moderate correlation between ranking of participants for PL (0.593–0.764) and PL · min1 (0.282–0.736). It was concluded that monitoring PL® in football multidirectional actions presents moderate-to-high reliability, that between-participant variability most likely relies on the individual’s locomotive skills and not their anthropometrics, and that the intensity of a task expressed by PL · min1 is largely related to the running velocity of the task.  相似文献   

6.
This study analysed the validity and reliability of a new optoelectronic device (Velowin) for the measurement of vertical displacement and velocity as well as to estimate force and mechanical power. Eleven trained males with Mean (SD) age = 27.4 (4.8) years, completed an incremental squat exercise test with 5 different loads (<30–90% of their 1?repetition maximum) while displacement and vertical velocity of the barbell were simultaneously measured using an integrated 3D system (3D motion capture system + force platform) and Velowin. Substantial to almost perfect correlation (concordance correlation coefficient = 0.75–0.96), root mean square error as coefficient of variation ±90% confidence interval ≤10% and good to excellent intraclass correlation coefficient = 0.84–0.99 were determined for all the variables. Passing and Bablock regression methods revealed no differences for average velocity. However, significant but consistent bias were determined for average or peak force and power while systematic and not proportional bias was found for displacement. In conclusion, Velowin, in holds of some potential advantages over traditionally used accelerometer or linear transducers, represents a valid and reliable alternative to monitor vertical displacement and velocity as well as to estimate average force and mechanical power during the squat exercise.  相似文献   

7.
The biomechanical evaluation of elite athletes often requires the use of sophisticated laboratory-based equipment that is restrictive, cumbersome, and often unsuitable for use in a training and competition environment. Small, low-mass unobtrusive centre-of-mass triaxial accelerometers can be used to collect data but may not reveal all the information of interest. This validation of centre-of-mass triaxial accelerometry uses previously reported synchronously collected foot-contact information from in-shoe pressure sensors. A qualitative assessment of the system output indicates that the centre-of-mass acceleration provides valuable insight into the use of accelerometers for investigating the biomechanics of, in this case, middle distance runners.  相似文献   

8.
Tibial acceleration is a surrogate measure for impact loading and lower limb fatigue injury in runners. Triaxial accelerometers may offer reliable and practical measurement of resultant peak tibial acceleration (PTA). With such potential in mind, this study examined variability and measurement reliability of tibial acceleration in 14 runners at baseline at one week, and eight of the runners again at six months. Triaxial accelerometers were attached to the distal tibiae of runners before they ran on a treadmill for two minutes each, at speeds of 2.7, 3.0, 3.3 and 3.7 m/s in standardised shoes. Resultant PTAs were calculated for each speed and session. Reliability outcomes were presented as percentage change and effect sizes. Variability outcomes included intraclass correlation coefficients and the typical error of the measurement. Smallest worthwhile change and performance/noise ratio were also calculated. While runners demonstrated marginally lower reliability and higher variability over six months, compared to one week, in all cases the measures of reliability and variability were of ‘good’ to ‘moderate’ reliability, and ‘small’ to ‘moderate’ variability using magnitude-based inferences. We can be confident that resultant PTA can be used with runners to assess and monitor their impacts throughout a six-month intervention.  相似文献   

9.
This study assessed the validity of a tri-axial accelerometer worn on the upper body to estimate peak forces during running and change-of-direction tasks. Seventeen participants completed four different running and change-of-direction tasks (0°, 45°, 90°, and 180°; five trials per condition). Peak crania-caudal and resultant acceleration was converted to force and compared against peak force plate ground reaction force (GRF) in two formats (raw and smoothed). The resultant smoothed (10 Hz) and crania-caudal raw (except 180°) accelerometer values were not significantly different to resultant and vertical GRF for all running and change-of-direction tasks, respectively. Resultant accelerometer measures showed no to strong significant correlations (r = 0.00–0.76) and moderate to large measurement errors (coefficient of variation [CV] = 11.7–23.9%). Crania-caudal accelerometer measures showed small to moderate correlations (r = ? 0.26 to 0.39) and moderate to large measurement errors (CV = 15.0–20.6%). Accelerometers, within integrated micro-technology tracking devices and worn on the upper body, can provide a relative measure of peak impact force experienced during running and two change-of-direction tasks (45° and 90°) provided that resultant smoothed values are used.  相似文献   

10.
ABSTRACT

Introduction: This study examined the concurrent validity and inter-pair reliability of the proximity detection function on Bluetooth-enabled accelerometers across manufacturer-specified ranges. If valid, this method could be used for objectively measuring shared physical activity participation. Method: Thirty-six dyads aged 21.6 (2.1) years wore two sets of Bluetooth-enabled accelerometers initialized as beacons and receivers to compare accelerometer-measured proximity detection to direct observation under 11 different controlled and free-living conditions. Results: The proportion of minutes in which proximity was detected differed across conditions (p < .001), with the highest proportions in the controlled conditions (.77–1.0). Among the free-living conditions, the different room (.73 ± .20) condition had the highest proximity detection proportions. There were no differences in the proximity detection across accelerometer pairs (p = .265). Conclusion: Proximity detection with Bluetooth-enabled accelerometers was reliable and had the highest detection rates under the controlled treadmill walking conditions. Despite limitations, using Bluetooth-enabled accelerometers is a promising approach for measuring shared physical activity.  相似文献   

11.
The purpose of this study was to assess the validity of accelerometers using force plates (i.e., ground reaction force (GRF)) during the performance of different tasks of daily physical activity in children. Thirteen children (10.1 (range 5.4–15.7) years, 3 girls) wore two accelerometers (ActiGraph GT3X+ (ACT), GENEA (GEN)) at the hip that provide raw acceleration signals at 100 Hz. Participants completed different tasks (walking, jogging, running, landings from boxes of different height, rope skipping, dancing) on a force plate. GRF was collected for one step per trial (10 trials) for ambulatory movements and for all landings (10 trials), rope skips and dance procedures. Accelerometer outputs as peak loading (g) per activity were averaged. ANOVA, correlation analyses and Bland–Altman plots were computed to determine validity of accelerometers using GRF. There was a main effect of task with increasing acceleration values in tasks with increasing locomotion speed and landing height (P < 0.001). Data from ACT and GEN correlated with GRF (r = 0.90 and 0.89, respectively) and between each other (r = 0.98), but both accelerometers consistently overestimated GRF. The new generation of accelerometer models that allow raw signal detection are reasonably accurate to measure impact loading of bone in children, although they systematically overestimate GRF.  相似文献   

12.
Research has focused on parameters that are associated with injury risk, e.g. vertical acceleration. These parameters can be influenced by running on different surfaces or at different running speeds, but the relationship between them is not completely clear. Understanding the relationship may result in training guidelines to reduce the injury risk. In this study, thirty-five participants with three different levels of running experience were recruited. Participants ran on three different surfaces (concrete, synthetic running track, and woodchip trail) at two different running speeds: a self-selected comfortable speed and a fixed speed of 3.06 m/s. Vertical acceleration of the lower leg was measured with an accelerometer. The vertical acceleration was significantly lower during running on the woodchip trail in comparison with the synthetic running track and the concrete, and significantly lower during running at lower speed in comparison with during running at higher speed on all surfaces. No significant differences in vertical acceleration were found between the three groups of runners at fixed speed. Higher self-selected speed due to higher performance level also did not result in higher vertical acceleration. These results may show that running on a woodchip trail and slowing down could reduce the injury risk at the tibia.  相似文献   

13.
Ground reaction force measurements are a fundamental element of kinetic analyses of locomotion, yet they are traditionally constrained to laboratory settings or stationary frames. This study assessed the validity and reliability of a new wireless in-shoe system (Novel Loadsol/Pedoped) for field-based ground reaction force measurement in hopping, walking, and running. Twenty participants bilaterally hopped on a force plate and walked (5 km/hr) and ran (10 km/hr) on an instrumented treadmill on two separate days while wearing the insoles. GRFs were recorded simultaneously on each respective system. Peak GRF in hopping and peak GRF, contact time (CT), and impulse (IMP) in walking and running were compared on a per-hop and step-by-step basis. In hopping, the insoles demonstrated excellent agreement with the force plate (ICC: 0.96). In walking and running, the insoles demonstrated good-to-excellent agreement with the treadmill across all measures (ICCs: 0.88–0.96) and were reliable across sessions (ICCs within 0.00–0.03). A separate verification study with ten participants was conducted to assess a correction algorithm for further agreement improvement but demonstrated little meaningful change in systemic agreements. These results indicated that the Novel Loadsol system is a valid and reliable tool for wireless ground reaction force measurement in hopping, walking, and running.  相似文献   

14.
Abstract

The purpose of this study was to validate peak acceleration data from an accelerometer contained within a wearable tracking device while walking, jogging and running. Thirty-nine participants walked, jogged and ran on a treadmill while 10 peak accelerations per movement were obtained (n = 390). A single triaxial accelerometer measured resultant acceleration during all movements. To provide a criterion measure of acceleration, a 12-camera motion analysis (MA) system tracked the position of a retro-reflective marker affixed to the wearable tracking device. Peak raw acceleration recorded by the accelerometer significantly overestimated peak MA acceleration (P < 0.01). Filtering accelerometer data improved the relationship with the MA system (P < 0.01). However, only the 10 Hz and 8 Hz cut-off frequencies significantly reduced the errors found. The walk movement demonstrated the highest accuracy, agreement and precision and the lowest relative errors. Linear increases in error were observed for jog compared with walk and for run compared to both other movements. As the magnitude of acceleration increased, the strength of the relationship between the accelerometer and the criterion measure decreased. These results indicate that filtered accelerometer data provide an acceptable means of assessing peak accelerations, in particular for walking and jogging.  相似文献   

15.
High impact forces during gymnastic landings are thought to contribute to the high rate of injuries. Lower limb joint flexion is currently limited within gymnastic rules, yet might be an avenue for reduced force absorption. This study investigated whether lower limb flexion during three gymnastic landings was related to force. Differences between landings were also explored. Twenty-one elite women's artistic gymnasts performed three common gymnastic techniques: drop landing (DL), front and back somersaults. Ankle, knee, and hip angles, and vertical ground reaction force [(vGRF) magnitude and time to peak], were measured using three-dimensional motion analysis and force platform. The DL had significantly smaller peak vGRF, greater time to peak vGRF and larger lower limb flexion ranges than landing from either somersault. Peak vGRF and time to peak vGRF were inversely related. Peak vGRF was significantly reduced in gymnasts who landed with greater hip flexion, and time to peak was significantly increased with increasing ankle, knee, and hip flexion. Increased range of lower limb flexion should be encouraged during gymnastic landings to increase time to peak vGRF and reduce high impact force. For this purpose, judging criteria limitations on lower limb flexion should be reconsidered.  相似文献   

16.
The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players' classification and competition standard, and rating of coach and player. Six field tests' test-retest showed good reliability (Intraclass correlation coefficient (ICC) = 0.80-0.97), while the pass-for-accuracy, free throws, lay-up and spot shot showed weak to moderate reliability (ICC = 0.26-0.67). Most tests showed moderate to good validity (r > 0.60). The results suggest that wheelchair basketball field tests are reliable and valid with the exception of the shooting and passing items, which should be interpreted carefully.  相似文献   

17.
The effects of treadmill running on impact acceleration were examined together with the interaction between running surface and runner's fatigue state. Twenty recreational runners (11 men and 9 women) ran overground and on a treadmill (at 4.0 m/s) before and after a fatigue protocol consisting of a 30-minute run at 85% of individual maximal aerobic speed. Impact accelerations were analysed using two lightweight capacitive uniaxial accelerometers. A two-way repeated-measure analysis of variance showed that, in the pre-fatigue condition, the treadmill running decreased head and tibial peak impact accelerations and impact rates (the rate of change of acceleration), but no significant difference was observed between the two surfaces in shock attenuation. There was no significant difference in acceleration parameters between the two surfaces in the post-fatigue condition. There was a significant interaction between surface (treadmill and overground) and fatigue state (pre-fatigue and post-fatigue). In particular, fatigue when running overground decreased impact acceleration severity, but it had no such effect when running on the treadmill. The effects of treadmill running and the interaction need to be taken into account when interpreting the results of studies that use a treadmill in their experimental protocols, and when prescribing physical exercise.  相似文献   

18.
The purpose of this study was to assess validity and reliability of sprint performance outcomes measured with an iPhone application (named: MySprint) and existing field methods (i.e. timing photocells and radar gun). To do this, 12 highly trained male sprinters performed 6 maximal 40-m sprints during a single session which were simultaneously timed using 7 pairs of timing photocells, a radar gun and a newly developed iPhone app based on high-speed video recording. Several split times as well as mechanical outputs computed from the model proposed by Samozino et al. [(2015). A simple method for measuring power, force, velocity properties, and mechanical effectiveness in sprint running. Scandinavian Journal of Medicine & Science in Sports. https://doi.org/10.1111/sms.12490] were then measured by each system, and values were compared for validity and reliability purposes. First, there was an almost perfect correlation between the values of time for each split of the 40-m sprint measured with MySprint and the timing photocells (r?=?0.989–0.999, standard error of estimate?=?0.007–0.015?s, intraclass correlation coefficient (ICC)?=?1.0). Second, almost perfect associations were observed for the maximal theoretical horizontal force (F0), the maximal theoretical velocity (V0), the maximal power (Pmax) and the mechanical effectiveness (DRF – decrease in the ratio of force over acceleration) measured with the app and the radar gun (r?=?0.974–0.999, ICC?=?0.987–1.00). Finally, when analysing the performance outputs of the six different sprints of each athlete, almost identical levels of reliability were observed as revealed by the coefficient of variation (MySprint: CV?=?0.027–0.14%; reference systems: CV?=?0.028–0.11%). Results on the present study showed that sprint performance can be evaluated in a valid and reliable way using a novel iPhone app.  相似文献   

19.
Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s–1 with three accelerometers attached with double-sided tape and tightened to the participants’ tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.  相似文献   

20.
The aim of this study was to determine the intra-participant variabilities (i.e. intra-day and inter-day reliabilities) in leg and vertical stiffness, as well as related kinematic parameters, during treadmill running using the sine-wave method. Twenty-two healthy men ran on a treadmill at 4.44 m/s, and the flight and contact times were measured with a high-speed video camera. Three 30-s running bouts with 2-min inter-bout rests were performed to examine the intra-day reliability, and single 30-s running bouts on three separate days with 24- to 48-h inter-bout intervals were performed to examine the inter-day reliability. The reliability statistics included repeated-measure analyses of variance, average inter-trial correlations, intra-class correlation coefficients (ICCs), Cronbach's α reliability coefficient, and the coefficient of variation. Both leg and vertical stiffness produced high ICCs within 0.972 and 0.982, respectively, and between 0.922 and 0.873 days, respectively. High values were also observed for all of the reliability coefficients. Similar results were found regarding contact time, flight time, step length, and step rate. It was concluded that the measurements of leg and vertical stiffness, as well as related kinematic parameters, obtained using the sine-wave method during treadmill running at 4.44 m/s, were highly reliable, both within and across days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号