首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper presents a mathematical model for laser-induced rapid electro-kinetic patterning (REP) to elucidate the mechanism for concentrating particles in a microchannel non-destructively and non-invasively. COMSOL®(v4.2a) multiphysics software was used to examine the effect of a variety of parameters on the focusing performance of the REP. A mathematical model of the REP was developed based on the AC electrothermal flow (ACET) equations, the dielectrophoresis (DEP) equation, the energy balance equation, the Navier-Stokes equation, and the concentration-distribution equation. The medium was assumed to be a diluted solute, and different electric potentials and laser illumination were applied to the desired place. Gold (Au) electrodes were used at the top and bottom of a microchannel. For model validation, the simulation results were compared with the experimental data. The results revealed the formation of a toroidal microvortex via the ACET effect, which was generated due to laser illumination and joule-heating in the area of interest. In addition, under some conditions, such as the frequency of AC, the DEP velocity, and the particle size, the ACET force enhances and compresses resulting in the concentration of particles. The conditions of the DEP velocity and the ACET velocity are presented in detail with a comparison of the experimental results.  相似文献   

2.
With the fast development of acoustic systems in clinical and therapeutic applications, acoustically driven microbubbles have gained a prominent role as powerful tools to carry, transfer, direct, and target drug molecules in cells, tissues, and tumors in the expanding fields of targeted drug delivery and gene therapy. The aim of the present study is to establish a biocompatible acoustic microfluidic system and to demonstrate the generation of an acoustic field and its effects on microbubbles and biological cells in the microfluidic system. The acoustic field creates non-linear oscillations of the microbubble-clusters, which results in generation of shear stress on cells in such microsystems. This effectively helps in delivering extracellular probes in living cells by sonoporation. The sonoporation is investigated under the combined effects of acoustic stress and hydrodynamic stress during targeted drug and gene delivery.  相似文献   

3.
海啸灾害的数值模拟研究   总被引:4,自引:0,他引:4  
海啸的数值模拟研究在帮助理解海啸自然灾害的物理特性及预防减灾方面具有重要意义.总结了当前海啸数值模拟的常用方法,包括对它们物理特性的描述,物理过程的划分,不同过程所采用的控制方程,常用的数值模拟方法,及模拟的重点和难点.在此基础上,介绍了当 前国际上有影响力的一些海啸数值模型,及其实现方法与特点,对于研究者开展自己的研究具有借鉴意义.  相似文献   

4.
Implantable drug delivery systems can provide long-term reliability, controllability, and biocompatibility, and have been used in many applications, including cancer pain and non-malignant pain treatment. However, many of the available systems are limited to zero-order, inconsistent, or single burst event drug release. To address these limitations, we demonstrate prototypes of a remotely operated drug delivery device that offers controllability of drug release profiles, using osmotic pumping as a pressure source and magnetically triggered membranes as switchable on-demand valves. The membranes are made of either ethyl cellulose, or the proposed stronger cellulose acetate polymer, mixed with thermosensitive poly(N-isopropylacrylamide) hydrogel and superparamagnetic iron oxide particles. The prototype devices'' drug diffusion rates are on the order of 0.5–2 μg/h for higher release rate designs, and 12–40 ng/h for lower release rates, with maximum release ratios of 4.2 and 3.2, respectively. The devices exhibit increased drug delivery rates with higher osmotic pumping rates or with magnetically increased membrane porosity. Furthermore, by vapor deposition of a cyanoacrylate layer, a drastic reduction of the drug delivery rate from micrograms down to tens of nanograms per hour is achieved. By utilizing magnetic membranes as the valve-control mechanism, triggered remotely by means of induction heating, the demonstrated drug delivery devices benefit from having the power source external to the system, eliminating the need for a battery. These designs multiply the potential approaches towards increasing the on-demand controllability and customizability of drug delivery profiles in the expanding field of implantable drug delivery systems, with the future possibility of remotely controlling the pressure source.  相似文献   

5.
溃坝问题在水利工程的设计管理中具有重要地位,也是广大学者长期以来一直关注和研究的课题。本文从数值模拟方向对溃坝问题进行综述,回顾和总结了目前国内外在数值模拟研究溃坝所采用的方法、已取得的成果及研究进展,并提出了进一步研究的方向和发展趋势。  相似文献   

6.
对2款外部尺寸相同、内部毛细芯结构不同的均热板进行理论分析与数值分析.结果表明,1)内部具有烧结铜粉柱体的均热板热性能更加优良,这是由于烧结铜粉柱体缩短了工质的回流通路与时间;2)数值分析对均热板结构优化与热性能的提高具有指导意义.  相似文献   

7.
This paper characterizes oscillations found in block pulse function (BPF) domain identification of open loop first-order systems with step input. A useful condition for occurrence of such oscillations is presented mathematically. For any positive value of ‘ah’, oscillations are observed to occur, where h is the width of BPF domain sub-interval and 1/a is the time constant of the first-order system under consideration.  相似文献   

8.
We discuss the ability to perform fluorescent immunocytochemistry, following cell fixation, using a microfluidic array of primary, nonadherent, single CD34+ stem cells. The technique requires small cell samples and proceeds with no cell loss, making it well-suited to monitoring these rare patient-derived cells. The chip allows us to correlate live cell dynamics across arrays of individual cells with post-translational modifications of intracellular proteins, following their exposure to drug treatments. Results also show that due to the microfluidic environment, the time scale of cell fixation was significantly reduced compared to conventional methods, leading to greater confidence in the status of the protein modifications studied.  相似文献   

9.
Nebulizers have considerable advantages over conventional inhalers for pulmonary drug administration, particularly because they do not require coordinated breath actuation to generate and deliver the aerosols. Nevertheless, besides being less amenable to miniaturization and hence portability, some nebulizers are prone to denature macromolecular drugs due to the large forces generated during aerosolization. Here, we demonstrate a novel portable acoustomicrofluidic device capable of nebulizing epidermal growth factor receptor (EGFR) monoclonal antibodies into a fine aerosol mist with a mass median aerodynamic diameter of approximately 1.1 μm, optimal for deep lung deposition via inhalation. The nebulized monoclonal antibodies were tested for their stability, immunoactivity, and pharmacological properties, which confirmed that nebulization did not cause significant degradation of the antibody. In particular, flow cytometry demonstrated that the antigen binding capability of the antibody is retained and able to reduce phosphorylation in cells overexpressing the EGFR, indicating that the aerosols generated by the device were loaded with stable and active monoclonal antibodies. The delivery of antibodies via inhalation, particularly for the treatment of lung cancer, is thus expected to enhance the efficacy of this protein therapeutic by increasing the local concentration where they are needed.  相似文献   

10.
This paper presents a numerical study of a preconcentrator design that can effectively increase the binding rate at the sensor in a real time manner. The particle enrichment is realized by the ac electrothermal (ACET) effect, which induces fluid movement to carry nanoparticles toward the sensor. The ACET is the only electrical method to manipulate a biological sample of medium to high ionic strength (>0.1 S∕m, e.g., 0.06× phosphate buffered saline). The preconcentrator consists of a pair of electrodes striding over the sensor, simple to implement as it is electrically controlled. This preconcentrator design is compatible and can be readily integrated with many types of micro- to nanosensors. By applying an ac signal over the electrodes, local vortices will generate a large velocity perpendicular to the reaction surface, which enhances transport of analytes toward the sensor. Our simulation shows that the binding rate at the sensor surface is greatly enhanced. Our study also shows that the collection of analytes will be affected by various parameters such as channel height, inlet velocity, and sensor size, and our results will provide guidance in optimization of the preconcentrator design.  相似文献   

11.
We report a refillable and valveless drug delivery device actuated by an external magnetic field for on-demand drug release to treat localized diseases. The device features a pear-shaped viscoelastic magnetic membrane inducing asymmetrical deflection and consecutive touchdown motion to the bottom of the dome-shaped drug reservoir in response to a magnetic field, thus achieving controlled discharge of the drug. Maximum drug release with 18 ± 1.5 μg per actuation was achieved under a 500 mT magnetic flux density, and various controlled drug doses were investigated with the combination of the number of accumulated actuations and the strength of the magnetic field.  相似文献   

12.
以4100柴油发动机为研究对象,用fire软件模拟分析不同EGR对生物柴油燃烧性能和排放的影响。结果表明,应用EGR,能有效降低生物柴油发动机NOX的排放,但同时发动机的动力性和经济性会有一定幅度的下降;EGR率的增加会给柴油机的动力性、燃油消耗率、烟度的排放带来不同程度的负面影响,使柴油机的最大爆发压力及放热率峰值下降。  相似文献   

13.
煤炭是我国的主要能源之一.随着社会的发展和煤炭资源开发的日益加强,矿井的开采深度也在不断增大,伴随开采深度的逐步增加,地温也随之升高.随着煤矿开采深度的增加,矿井巷道、工作面等的温度过高,形成热害.为治理热富,大多数都采用了空调制冷技术,但构成井巷热环境的各要素是随时间变化的,岩层和岩温是各向异性的,风流是湍流的,为设计和研究带来相当多的麻烦.随着CFD技术的发展,运用计算机模拟巷道的场变化,是矿井降温研究新的也是有效的方法.本文运用CFD软件对掘进巷道的温度场进行了模拟.  相似文献   

14.
One challenge of generating a liquid aerosol is finding an efficient way to break up bulk amounts of the compound into micron-sized droplets. Traditional methods of aerosol generation focus on the principle of creating the liquid droplets by blowing air at high speed over or through a liquid. In this study, a novel micropump droplet generator (MDG) is proposed based on a microfluidics device to produce monodisperse droplets on demand (DoD). The micropump design was employed to both pump the fluid into the air and to encourage droplet breakup and aerosol formation. Computational simulation modeling of the new MDG was developed and validated with comparisons to experimental data for current generators. The device was found to produce an aerosol similar to a vibrating orifice DoD device. Most importantly, the input power required by the newly proposed device (MDG) was several orders of magnitude below existing DoD generators for a similar droplet output. Based on the simulation results obtained in comparison with current DoD generators, the MDG device performed effectively at higher frequencies, smaller nozzle diameters, and regardless of the liquid viscosity of the solution.  相似文献   

15.
利用CFD软件Fluent的前处理软件Gambit建立与实际系统相同的单U竖直地埋管换热器的三维非稳态传热模型,进行传热模拟仿真,通过得出的地能井与U型管中温度的变化图形来分析温度变化趋势,并与实验测试结果进行比较,结果表明,实验值和仿真结果很接近。这有利于掌握在没有预先埋好热电偶的情况下去观察地能井温度的变化。  相似文献   

16.
Polymer-based microneedles have drawn much attention in the transdermal drug delivery resulting from their flexibility and biocompatibility. Traditional fabrication approach deploys various kinds of molds to create sharp tips at the end of needles for the penetration purpose. This approach is usually time-consuming and expensive. In this study, we developed an innovative fabrication process to make biocompatible SU-8 microtubes integrated with biodissolvable maltose tips as novel microneedles for the transdermal drug delivery applications. These microneedles can easily penetrate the skin''s outer barrier represented by the stratum corneum (SC) layer. The drug delivery device of mironeedles array with 1000 μm spacing between adjacent microneedles is proven to be able to penetrate porcine cadaver skins successfully. The maximum loading force on the individual microneedle can be as large as 7.36 ± 0.48N. After 9 min of the penetration, all the maltose tips are dissolved in the tissue. Drugs can be further delivered via these open biocompatible SU-8 microtubes in a continuous flow manner. The permeation patterns caused by the solution containing Rhodamine 110 at different depths from skin surface were characterized via a confocal microscope. It shows successful implementation of the microneedle function for fabricated devices.  相似文献   

17.
赵明旺 《科技通报》1996,12(6):356-362
先运用多项式分解,将严格正则线性系统同时镇定问题化成一组相容非线性方程的求解,然后提出了一种求解相容非线性方程组的拟牛顿下山数值算法,并应用该方法求解同时镇定问题。算例表明本文方法的有效性。  相似文献   

18.
Polymer-based microneedles have drawn much attention in transdermal drug delivery resulting from their flexibility and biocompatibility. Traditional fabrication approaches are usually time-consuming and expensive. In this study, we developed a new double drawing lithography technology to make biocompatible SU-8 microneedles for transdermal drug delivery applications. These microneedles are strong enough to stand force from both vertical direction and planar direction during penetration. They can be used to penetrate into the skin easily and deliver drugs to the tissues under it. By controlling the delivery speed lower than 2 μl/min per single microneedle, the delivery rate can be as high as 71%.Microelectromechanical systems (MEMS) technology has enabled wide range of biomedical devices applications, such as micropatterning of substrates and cells,1 microfluidics,2 molecular biology on chips,3 cells on chips,4 tissue microengineering,5 and implantable microdevices.6 Transdermal drug delivery using MEMS based devices can delivery insoluble, unstable, or unavailable therapeutic compounds to reduce the amount of those compounds used and to localize the delivery of potent compounds.7 Microneedles for transdermal drug delivery are increasingly becoming popular due to their minimally invasive procedure,8 promising chance for self-administration,9 and low injury risks.10 Moreover, since pharmaceutical and therapeutic agents can be easily transported into the body through the skin by microneedles,11, 12 the microneedles are promising to replace traditional hypodermic needles in the future. Previously, various microneedles devices for transdermal drug delivery applications have been reported. They have been successfully fabricated by different materials, including silicon,13 stainless steel,14 titanium,15 tantalum,16 and nickel.17 Although microneedles with these kinds of materials can be easily fabricated into sharp shape and offer the required mechanical strength for penetration purpose, such microneedles are prone to be damaged18 and may not be biocompatible.19 As a result, polymer based microneedles, such as SU-8,20, 21 polymethyl meth-acrylate (PMMA),22, 23 polycarbonates (PCs),24, 25 maltose,26, 27 and polylactic acid (PLA),28, 29 have caught more and more attentions in the past few years. However, in order to obtain ultra-sharp tips for penetrating the barrier layer of stratum corneum,30 conventional fabrication technologies, for instances, PDMS (Polydimethylsiloxane) molding technology,31, 32 stainless steel molding technology,33 reactive ion etching technology,34 inclined UV (Ultraviolet) exposure technology,35 and backside exposure with integrated lens technology36 are time-consuming and expensive. In this paper, we report an innovative double drawing lithography technology for scalable, reproducible, and inexpensive microneedle devices. Drawing lithography technology37 was first developed by Lee et al. They leveraged the polymers'' different viscosities under different temperatures to pattern 3D structures. However, it required that the drawing frames need to be regular cylinders, which is not proper for our devices. To solve the problem, the new double drawing lithography is developed to create sharp SU-8 tips on the top of four SU-8 pillars for penetration purpose. Drugs can flow through the sidewall gaps between the pillars and enter into the tissues under the skin surface. The experiment results indicate that the new device can have larger than 1N planar buckling force and be easily penetrated into skin for drugs delivery purpose. By delivering glucose solution inside the hydrogel, the delivering rate of the microneedles can be as high as 71% when the single microneedle delivery speed is lower than 2 μl/min.An array of 3 × 3 SU-8 supporting structures was patterned on a 140 μm thick, 6 mm × 6 mm SU-8 membrane (Fig. (Fig.1a).1a). Each SU-8 supporting structure included four SU-8 pillars and was 350 μm high. The four pillars were patterned into a tubelike shape on the membrane (Fig. (Fig.1b).1b). The inner diameter of the tube was 150 μm, while the outer diameter was 300 μm. SU-8 needles of 700 μm height were created on the top of SU-8 supporting structures to ensure the ability of transdermal penetration. Two PDMS layers were bonded with SU-8 membrane to form a sealed chamber for storing drugs from the connection tube. Once the microneedles entered into the tissue, drugs could be delivered into the body through the sidewall gaps between the pillars (Fig. (Fig.1c1c).Open in a separate windowFigure 1Schematic illustration of the SU-8 microneedles. (a) Overview of the whole device; (b) SU-8 supporting structures made of 4 SU-8 pillars; and (c) enlarged view of a single SU-8 microneedle.The fabrication process of SU-8 microneedles is shown in Fig. Fig.2.2. SU-8 microneedles fabrication started from a layer of Polyethylene Terephthalate (PET, 3M, USA) film pasted on the Si substrate by sticking the edge area with kapton tape (Fig. (Fig.2a).2a). The PET film, a kind of transparent film with poor adhesion to SU-8, was used as a sacrificial layer to dry release the final device from Si substrate. A 140 μm thick SU-8 layer was deposited on the top of this PET film. To ensure a uniform surface of this thick SU-8 layer, the SU-8 deposition was conducted in two steps coating. After exposed under 450 mJ/cm2 UV, the membrane pattern could be defined (Fig. (Fig.2b).2b). In order to ensure an even surface for following spinning process, another 350 μm SU-8 layer was directly deposited on this layer in two steps without development. With careful alignment, an exposure of 650 mJ/cm2 UV energy was performed on this 350 μm SU-8 layer to define the SU-8 supporting structures (Fig. (Fig.2c).2c). The SU-8 structure could be easily released from the PET substrate by removing the kapton tape and slightly bending the PET film. Two PDMS layers were bonded with this SU-8 structure by a method reported by Zhang et al.38 (Fig. (Fig.2d2d).Open in a separate windowFigure 2Fabrication process for SU-8 microtubes. (a) Attaching a PET film on the Si substrate; (b) exposing the first layer of SU-8 membrane without development; (c) depositing and patterning two continuous SU-8 layers as sidewall pillars; (d) releasing the SU-8 structure from the substrate and bonding it with PDMS; (e) drawing hollowed microneedles on the top of supporting structures; (f) baking and melting the hollowed microneedles to allow the SU-8 flow in the gaps between pillars; and (g) drawing second time on the top of the melted SU-8 flat surface to get microneedles.In our previous work,39 we used one time stepwise controlled drawing lithography technology for the sharp tips integration. However, since the frame used to conduct drawing process in present study is a four-pillars structure rather than a microtube, the conventional drawing process can only make a hollowed tip but not a solid tip structure (Fig. (Fig.3).3). This kind of tip was fragile and could not penetrate skin in the practical testing process. To solve the problem, we developed an innovative double drawing lithography process. After bonding released SU-8 structure with PDMS layers (Fig. (Fig.2d),2d), we used it to conduct first time stepwise controlled drawing lithography37 and got hollowed tips (Fig. (Fig.2e).2e). Briefly, the SU-8 was spun on the Si substrate and kept at 95 °C until the water inside completely vaporized. Device of SU-8 supporting structures was fixed on a precision stage. Then, the SU-8 supporting structures were immersed into the SU-8 by adjusting the precision state. The SU-8 were coated on the pillars'' surface. Then, the SU-8 supporting structures were drawn away from the interface of the liquid maltose and air. After that, the temperature and drawing speed were increased. Since the SU-8 was less viscous at higher temperature, the connection between the SU-8 supporting structures and surface of the liquid SU-8 became individual SU-8 bridge, shrank, and then broke. The end of the shrunk SU-8 bridge forms a sharp tip on the top of each SU-8 supporting structure when the connection was separated. After the hollowed tips were formed in the first step drawing process, the whole device was baked on the hotplate to melt the hollowed SU-8 tips. Melted SU-8 reflowed into the gaps between four pillars and the tips became domes (Fig. (Fig.2f).2f). Then, a second drawing process was conducted on the top of melted SU-8 to form sharp and solid tips (Fig. (Fig.2g).2g). The final fabricated device is shown in Fig. Fig.44.Open in a separate windowFigure 3A hollowed SU-8 microneedle fabricated by single drawing lithography technology (scale bar is 100 μm).Open in a separate windowFigure 4Optical images for the finished SU-8 microneedles.During the double drawing process, as long as the heated time and temperature were controlled, the SU-8 flow-in speed of SU-8 inside the gaps could be precisely determined. The relationship between baking temperature and flow-in speed was studied. As shown in Fig. Fig.5,5, the flow-in speed is positive related to the baking temperature. The explanation for this phenomena is that the SU-8''s viscosity is different under different baking temperatures.40 Generally, baked SU-8 has 3 status when temperature increases, solid, glass, and liquid. The corresponding viscosity will decrease and the SU-8 can also have higher fluidity. When the baking temperature is larger than 120 °C, the flow-in speed will increase sharply. But, if the baking temperature is higher, the SU-8 will reflow in the gaps too fast, which makes the flow-in depth hard to be controlled. There is a high chance that the whole gaps will be blocked, and no drugs can flow through these gaps any more. Considering that the total SU-8 supporting structure is only 350 μm high, we choose 125 °C as baking temperature for proper SU-8 flow-in speed and easier SU-8 flow-in depth control.Open in a separate windowFigure 5The relationship between flow-in speed and baking temperature.To ensure the adequate stiffness of the SU-8 microneedles in vertical direction, Instron Microtester 5848 (Instron, USA) was deployed to press the microneedles with the similar method reported by Khoo et al.41 As shown in Fig. Fig.6a,6a, the vertical buckling force was as much as 8.1N, which was much larger than the reported minimal required penetration force.42 However, in the previous practical testing experiments, even though the microneedles were strong enough in vertical direction, the planar shear force induced by skin deformation might also break the interface between SU-8 pillars and top tips. In our new device with four pillars supporting structure, the SU-8 could flow inside the sidewall gaps between the pillars to form anchors. These anchors could enhance microneedles'' mechanical strength and overcome the planar shear force problems. Moreover, the anchors strength could be improved by controlling the SU-8 flow-in depth. Fig. Fig.77 shows that the flow-in depth increases when the baking time increases as the baking time increases at 125 °C. Fig. Fig.6b6b shows that the corresponding planar buckling force can be improved to be larger than 1 N by increasing flow-in depth. Some sidewall gaps at bottom are kept on purpose for drugs delivery; hence, the flow-in depth is chosen as 200 μm.Open in a separate windowFigure 6(a) Measurement of the vertical buckling force. (b) The planar buckling force varies under different flow-in depth (I, II, III, and IV corresponding to the certain images in Fig. Fig.77).Open in a separate windowFigure 7Different flow-in depth inside the gaps between SU-8 pillars. (a) 0 μm; (b) 100 μm; (c) 200 μm; and (d) 350 μm (scale bar is 100 μm).The penetration capability of the 3 × 3 SU-8 microneedles array is characterized by conducting the insertion experiment on the porcine cadaver skin. 10 microneedles devices were tested and all of them were strong enough to be inserted into the tissue without any breakage. Histology images of the skin at the site of one microneedle penetration were derived to prove that the sharp conical tip was not broken during the insertion process (Fig. (Fig.8).8). It also shows penetrated evidence because the hole shape is the same as the sharp conical tip.Open in a separate windowFigure 8Histology image of individual microneedle penetration (scale bar is 100 μm).In order to verify that the drug solution can be delivered into tissue from the sidewall gaps of the microneedles, FITC (Fluorescein isothiocyanate) (Sigma Aldrich, Singapore) solution was delivered through the SU-8 microneedles after they were penetrated into the mouse cadaver skin. The representative results were then investigated via a confocal microscope (Fig. (Fig.9).9). The permeation pattern of the solution along the microchannel created by microneedles confirmed the solution delivery results. The black area was a control area without any diffused florescent solution. In contrast, the illuminated area in Fig. Fig.99 indicates the area where the solution has diffused to it. These images were taken consecutively from the skin surface down to 180 μm with 30 μm intervals. The diffusion area had a similar dimension with the inserted microneedles. It has proved that the device can be used to deliver drugs into the body.Open in a separate windowFigure 9Images of confocal microscopy to show the florescent solution is successfully delivered into the tissue underneath the skin surface. (a) 30 μm; (b) 60 μm; (c) 90 μm; (d) 120 μm; (e) 150 μm; and (f) 180 μm (scale bar is 100 μm).Due to the uneven surface of deformed skin, there is always tiny gap happened between tips of some microneedles and local surface skin. The microneedles could not be entirely inserted into the tissue. Drugs might leak to the skin surface through the sidewall gaps under certain driven pressure. Hydrogel absorption experiment was conducted to quantify the delivery rate (i.e., the ratio of solution delivered into tissues in the total delivered volume) and to optimize the delivery speed. Using hydrogel as the tissue model for quantitative analysis of microneedle releasing process was reported by Tsioris et al.43 The details are shown here. Gelatin hydrogel was prepared by boiling 70 ml DI (Deionized) water and mixing it with 7 g of KnoxTM original unflavored gelatin powder. The solution was poured into petri dish to 1 cm high. Then, the petri dish was put into a fridge for half an hour. Gelatin solution became collagen slabs. The collagen slabs were cut into 6 mm × 6 mm sections. A piece of fully stretched parafilm (Parafilm M, USA) was tightly mounted on the surface of the collagen slabs. This parafilm was used here to block the leaked solution further diffusing into the collagen slab in the delivery process. Then, the microneedles penetrated the parafilm and went into the collagen slab. Controlled by a syringe pump, 0.1 ml–0.5 mg/ml glucose solution was delivered into the collagen slab under different speeds. Methylene Blue (Sigma Aldrich, Singapore) was mixed into the solution for better inspection purpose (Fig. 10a). Then, the collagen slabs was digested in 1 mg/ml collagenase (Sigma Aldrich, Singapore) at room temperature (Fig. 10b). It took around 1 h that all the collagen slabs could be fully digested (Fig. 10d). The solution was collected to measure the glucose concentration with glucose detection kit (Abcam, Singapore). Briefly, both diluted glucose standard solution and the collected glucose solution were added into a series of wells in a well plate. Glucose assay buffer, glucose enzyme, and glucose substrate were mixed with these samples in the wells. After incubation for 30 min, their absorbance were examined by using a microplate reader at a wavelength of 450 nm. By comparing the readings with the measured concentration standard curve (Fig. 11a), the glucose concentration in the hydrogel, the glucose absorption rate in the hydrogel, and the solution delivery rate by microneedles could be measured and calculated. As shown in Fig. 11b, when the delivering speed of a single microneedle increased from 0.1 μl/min to 2 μl/min, the glucose absorption rate also increased. Most of the glucose solution from microneedles could go into the hydrogel. The delivered rate could be as high as 71%. The rest solution leaked from sidewall gaps and blocked by parafilm. However, when the delivered speed for a single microneedle was larger than 2 μl/min, the hydrogel absorption rate was saturated. More and more solution could not go into the hydrogel but leak from the sidewall gaps. Then, the delivered rate decreased. Therefore, 2 μl/min was chosen as the optimized delivery speed for the microneedle.Open in a separate windowFigure 10Glucose solution could be delivered into the hydrogel, and the collagen stabs were dissolved by collagenase.Open in a separate windowFigure 11(a) Standard curve for glucose detection; (b) glucose absorption rate and solution delivery rate in a single needle corresponding to different delivery speed.In conclusion, a drug delivery device of integrated vertical SU-8 microneedles array is fabricated based on a new double drawing lithography technology in this study. Compared with the previous biocompatible polymer-based microneedles fabrication technology, the proposed fabrication process is scalable, reproducible, and inexpensive. The fabricated microneedles are rather strong along both vertical and planar directions. It is proved that the microneedles were penetrated into the pig skin easily. The feasibility of drug delivery using SU-8 microneedles is confirmed by FITC fluorescent delivery experiment. In the hydrogel absorption experiment, by controlling the delivery speed under 2 μl/min per microneedle, the delivery rate provided the microneedle is as high as 71%. In the next step, the microneedles will be further integrated with microfluidics on a flexible substrate, forming a skin-patch like drug delivery device, which may potentially demonstrate a self-administration function. When patients need an injection treatment at home, they can easily use such a device just like using an adhesive bandage strip.  相似文献   

19.
Implantable drug delivery devices are becoming attractive due to their abilities of targeted and controlled dose release. Currently, two important issues are functional lifetime and non-controlled drug diffusion. In this work, we present a drug delivery device combining an electrolytic pump and a thermo-responsive valve, which are both remotely controlled by an electromagnetic field (40.5 mT and 450 kHz). Our proposed device exhibits a novel operation mechanism for long-term therapeutic treatments using a solid drug in reservoir approach. Our device also prevents undesired drug liquid diffusions. When the electromagnetic field is on, the electrolysis-induced bubble drives the drug liquid towards the Poly (N-Isopropylacrylamide) (PNIPAM) valve that consists of PNIPAM and iron micro-particles. The heat generated by the iron micro-particles causes the PNIPAM to shrink, resulting in an open valve. When the electromagnetic field is turned off, the PNIPAM starts to swell. In the meantime, the bubbles are catalytically recombined into water, reducing the pressure inside the pumping chamber, which leads to the refilling of the fresh liquid from outside the device. A catalytic reformer is included, allowing more liquid refilling during the limited valve''s closing time. The amount of body liquid that refills the drug reservoir can further dissolve the solid drug, forming a reproducible drug solution for the next dose. By repeatedly turning on and off the electromagnetic field, the drug dose can be cyclically released, and the exit port of the device is effectively controlled.  相似文献   

20.
By applying hybrid functions of general block-pulse functions and Legendre polynomials, linear Volterra integrodifferential systems are converted into a system of algebraic equations. The approximate solutions of linear Volterra integrodifferential systems are derived. Using the results we obtain the optimal control and state as well as the optimal value of the objective functional. The numerical examples illustrate that the algorithms are valid.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号