IntroductionThe aim of this study was to perform a comprehensive verification of a 6-part differential haematology analyser Siemens Advia 2120i (Erlangen, Germany), prior to its routine implementation.Materials and methodsOur verification protocol included: precision (within- and between-run), estimated bias (%) as measure of trueness, which was calculated from observed and manufacturers’ declared value, analytical measuring interval (AMI), carryover, confirmation of a limit of blank (LoB), determination of a limit of detection (LoD) and limit of quantitation (LoQ). The K2 ethylenediaminetetraacetic acid (EDTA) patients’ leftover samples were used for verification of analyser Advia 2021i. Acceptance criteria were based on manufacturer technical specifications (Siemens), 2016 state-of-the-art criteria (Vis and Huisman), and EFLM Biological Variation Database.ResultsThe within- and between-run precision were acceptable for all parameters and the lowest coefficients of variation were observed for mean corpuscular volume (MCV) (0.3% and 0.6%, respectively). Estimated bias was within the acceptance criteria for all parameters except for MCV (the estimated bias was 2.2% (acceptance criteria 2.0%). AMI was confirmed for all tested parameters (r > 0.99). The carryover estimates ranged from 0.1% for platelet count (Plt) to 0.6% for red blood cell count and were within the manufacturers’ specifications (≤ 1%). Manufacturers’ claims for LoB were confirmed for leukocytes, erythrocytes, haemoglobin, and platelets. The estimated LoD and LoQ were 0.05 x109/L and 0.1 x109/L for white blood cell count, while for Plt values were 2 x109/L and 3 x109/L, respectively.ConclusionsAnalytical performance of the Siemens Advia 2120i meets predefined quality goals and is suitable for routine use in a clinical laboratory.Key words: verification, haematology analyser, haematology, blood cell count  相似文献   

2.
IntroductionOesophageal varices are routinely diagnosed by esophagogastroduodenoscopy (EGD), and their bleeding has high mortality. We aimed to evaluate diagnostic performance of biochemical tests in comparison to elastography-based approaches, as non-invasive alternatives to EGD, for ruling-out high risk oesophageal varices (HRV).Material and methodsRetrospective analysis of patients (N = 861) who underwent liver stiffness measurement (LSM) by transient elastography (TE) in a single centre over 5-year period, with available results of EGD (within 3 months from LSM). Only patients with suspicion of compensated advanced chronic liver disease (cACLD) defined by LSM ≥ 10 kPa were included comprising the final cohort of 73 subjects. Original and expanded Baveno VI criteria (B6C), controlled attenuation parameter (CAP), platelet count (PLT), aspartate aminotransferase to PLT ratio index (APRI), Fibrosis-4 index (FIB4), model for end stage liver disease (MELD) score were evaluated against the results of EGD that served as the reference method.ResultsAnalysed patients had median age 62 years, 59/73 (0.81) were males, 54/73 (0.74) had alcoholic/non-alcoholic fatty liver disease, and 21/73 (0.29) had HRV. In multivariate logistic regression analysis only LSM and PLT were independently associated with HRV. The best performing tests for ruling-out HRV (% of spared EGD; % of missed HRV) were respectively: LSM < 20 kPa (53.4%; 0%), B6C (38%; 0%), Expanded B6C (47.9%; 4.8%); PLT > 214x109/L (21.9%; 0%); FIB4 ≤ 1.8 (21.4%; 0%), APRI ≤ 0.34 (12.3%; 0%). CAP, MELD = 6 alone or combined with PLT > 150(x109/L) did not show acceptable performance.ConclusionThe best performing biochemical tests for ruling-out HRV in our cohort of patients were PLT and FIB-4, but they were still outperformed by elastography-based approaches.Keyword: portal hypertension, cirrhosis, platelet count, esophageal varices, non-invasive tests  相似文献   

3.
IntroductionLeukolysis-related pseudohyperkalemia due to preanalytical procedures may lead to erroneous (or absence of) treatment based on an invalid lab test result. We aimed to obtain a leukocyte threshold above which leukolysis-related pseudohyperkalemia becomes clinical relevant. Secondly, temporal dynamics of treatment-induced leukocyte decrease were studied to allow tailored implementation of laboratory information system (LIS) decision rules based on the leukocyte threshold to avoid leukolysis-related pseudohyperkalemia.Materials and methodsPotassium results of AU5811 routine chemistry (Beckman Coulter, Brea, California, USA) and iStat point of care (POC) (Abbott Diagnostics, Chicago, Illinois, USA) analysers were compared, the latter method being insensitive to leukolysis caused by pre-analytical procedures. Potassium results were combined with leukocyte counts obtained using a Cell-Dyn Sapphire haematology analyser (Abbott Diagnostics, Santa Clara, California, USA), resulting in 132 unique data triplets. Regression analysis was performed to establish a leukocyte threshold. The Reference Change Value (√2 x Z x √(CVa2 + CVi2)) was used to calculate maximum allowable difference between routine analyser and POC potassium results (deltamax + 0.58 mmol/L). Temporal analysis on the treatment-induced leukocyte decrease was performed by plotting leukocyte counts in time for all patients above the threshold leukocyte count (N = 41).ResultsEstablished leukocyte threshold was 63 x109/L. Temporal analysis showed leukocyte counts below the threshold within 8 days of treatment for all patients.ConclusionsBased on performed analyses we were able to implement LIS decision rules to reduce pseudohyperkalemia due to preanalytical procedures. This implementation can contribute to a reduction in erroneous (or absence of) treatments in the clinic.  相似文献   

4.
IntroductionIndirect estimation of reference intervals (RIs) is straightforward and inexpensive procedure for determination of intra-laboratory RIs. We applied the indirect approach to assess RIs for haematological parameters in capillary blood of pre-school children, using results stored in our laboratory database.Materials and methodsWe extracted data from laboratory information system, for the results obtained by automatic haematology analyser in capillary blood of 154 boys and 146 girls during pre-school medical examination. Data distribution was tested, and logarithmic transformation was applied if needed. Reference intervals were calculated by the nonparametric percentile method.ResultsReference intervals were calculated for: RBC count (4.2-5.4 x1012/L), haemoglobin (114-146 g/L), MCH (25.0-29.4 pg), MCHC (321-368 g/L), RDW-SD (36.1-43.5 fL), WBC count (4.5-12.3 x109/L), neutrophils count (1.7-6.9 x109/L) and percentage (29.0-69.0%), lymphocytes count (1.6-4.4 x109/L) and percentage (21.9-60.7%), PLT (165-459 x109/L), MPV (8.1-11.4 fL) and PDW (9.2-14.4%). Gender specific RIs were calculated for monocytes count (male (M): 0.2-1.6 x109/L; female (F): 0.1-1.4 x109/L) and percentage (M: 2.5-18.3%; F: 1.8-16.7%), haematocrit (M: 0.34-0.42 L/L; F: 0.34-0.43 L/L), MCV (M: 73.4-84.6 fL; F: 75.5-84.2 fL) and RDW (M: 12.1-14.3%; F: 11.7-13.9%), due to observed gender differences in these parameters (P = 0.031, 0.028, 0.020, 0.012 and 0.001; respectively). Estimated RIs markedly varied from the literature based RIs that are used in the laboratory.ConclusionsIndirect method employed in this study enables straightforward assessment of RIs in pre-school children. Herein derived RIs differed from the literature-based ones, indicating the need for intra-laboratory determination of RIs for specific populations and sample types.  相似文献   

5.

Introduction

Centrifugation is an essential step for plasma preparation to remove residual elements in plasma, especially platelets and platelet-derived microparticles (PMPs). Our working hypothesis was that centrifugation as a preanalytical step may influence some coagulation parameters.

Materials and methods

Healthy young men were recruited (N = 17). For centrifugation, two protocols were applied: (A) the first centrifugation at 2500 x g for 15 min and (B) at 2500 x g for 20 min at room temperature with a light brake. In protocol (A), the second centrifugation was carried out at 2500 x g for 15 min, whereas in protocol (B), the second centrifugation involved a 10 min spin at 13,000 x g. Thrombin-antithrombin (TAT) and plasmin-antiplasmin (PAP) complexes concentrations were determined by enzyme-linked immunosorbent assays. PMPs were stained with CD41 antibody and annexin V, and analyzed by flow cytometry method. Procoagulant activity was assayed by the Calibrated Automated Thrombogram method as a slope of thrombin formation (CAT velocity).

Results

Median TAT and PAP concentrations did not differ between the centrifugation protocols. The high speed centrifugation reduced the median (IQR) PMP count in plasma from 1291 (841-1975) to 573 (391-1010) PMP/µL (P = 0.001), and CAT velocity from 2.01 (1.31-2.88) to 0.97 (0.82-1.73) nM/min (P = 0.049). Spearman’s rank correlation analysis showed correlation between TAT and PMPs in the protocol A plasma which was (rho = 0.52, P < 0.050) and between PMPs and CAT for protocol A (rho = 0.74, P < 0.050) and protocol B (rho = 0.78, P < 0.050).

Conclusion

Centrifugation protocols do not influence the markers of plasminogen (PAP) and thrombin (TAT) generation but they do affect the PMP count and procoagulant activity.Key words: cell-derived microparticles, blood coagulation tests, centrifugation, preanalytical phase  相似文献   

6.
IntroductionThe prognostic value of D-dimer (DD) in sepsis remains controversial. This study aimed to investigate the performance of DD for predicting sepsis mortality in the hospital and for identifying its potential correlates.Materials and methodsThe clinical and laboratory data of adult sepsis patients were extracted from the Medical Information Mart for Intensive Care III (MIMIC III, v1.4) database using the structured query language (SQL). The database contains critical illness admitted to the intensive care unit at Beth Israel Deaconess Medical Center between June 2001 and October 2012. The association between DD and mortality was investigated with receiver operating characteristic (ROC) curve, restricted cubic spline and logistic regression analysis. Subgroup analysis was also used for identifying DD correlates.ResultsThe study population consisted of 358 sepsis patients. Those who died during hospital stay (N = 160) had significantly higher DD values than those who survived (N = 198). The area under the ROC curve (AUC) of DD was 0.59 (P < 0.010). In subgroup analysis, white blood cell (WBC) count > 18 x109/L and vasopressor therapy significantly decreased DD diagnostic performance. Categorical DD value was independently associated with hospital mortality after sequential organ failure score (SOFA) and blood lactate adjustment. Restricted cubic spline analysis revealed a U-shape relationship between DD and in-hospital mortality.DiscussionWe conclude that the accuracy of DD for predicting in-hospital sepsis mortality depends on WBC count and vasopressor therapy. Both low and extremely elevated DD values are associated with higher risk of death.  相似文献   

7.
Acute and chronic toxicity studies were conducted to assess toxicity of a partially purified preparation from the water extract of the bark ofFicus bengalensis, which was demonstrated in our earlier studies to have significant hypoglycemic and hypocholesteroiemic effect on alloxan induced, mild and severe diabetes in rabbits. LD50 of this preparation was found to be ∼1 gm/kg in rats when given orally. For chronic toxicity studies 3 doses of aqueous preparation were given to 3 groups of rats. First group received 5 times ED50 (50 mg/kg), second group 10 times ED50 (100 mg/kg) and the third group 15 times ED50 (150 mg/kg) for 3 months. Fourth group which served as control was given water. After three months, blood was collected for studying biochemical and hematological parameters. Blood glucose, serum cholesterol, liver and kidney function tests, haemoglobin, total and differential leukocyte count were determined. Animals were sacrificed and histopathological examination of liver, heart and kidneys was carried out. Results of the study showed that partially purified preparation fromFicus bengalensis is not toxic by all the above mentioned parameters.  相似文献   

8.
Assessment of the dielectrophoresis (DEP) cross-over frequency (fxo), cell diameter, and derivative membrane capacitance (Cm) values for a group of undifferentiated human embryonic stem cell (hESC) lines (H1, H9, RCM1, RH1), and for a transgenic subclone of H1 (T8) revealed that hESC lines could not be discriminated on their mean fxo and Cm values, the latter of which ranged from 14 to 20 mF/m2. Differentiation of H1 and H9 to a mesenchymal stem cell-like phenotype resulted in similar significant increases in mean Cm values to 41–49 mF/m2 in both lines (p < 0.0001). BMP4-induced differentiation of RCM1 to a trophoblast cell-like phenotype also resulted in a distinct and significant increase in mean Cm value to 28 mF/m2 (p < 0.0001). The progressive transition to a higher membrane capacitance was also evident after each passage of cell culture as H9 cells transitioned to a mesenchymal stem cell-like state induced by growth on a substrate of hyaluronan. These findings confirm the existence of distinctive parameters between undifferentiated and differentiating cells on which future application of dielectrophoresis in the context of hESC manufacturing can be based.  相似文献   

9.
IntroductionThis study reevaluated von Willebrand disease (vWD) diagnosis in a Croatian paediatric cohort by combining bleeding scores (BS), phenotypic laboratory testing, and next-generation sequencing (NGS).Materials and methodsA total of 25 children (11 males and 14 females, median age 10 years, from 2 to 17) previously diagnosed with vWD were included. BS were calculated using an online bleeding assessment tool. Phenotypic laboratory analyses included platelet count, platelet function analyser closure times, prothrombin time, activated partial thromboplastin time, von Willebrand factor antigen (vWF:Ag), vWF gain-of-function mutant glycoprotein Ib binding activity (vWF:GPIbM), vWF collagen binding activity (vWF:CBA), factor VIII activity (FVIII:C) and multimeric analysis. Next-generation sequencing covered regions of both vWF and FVIII genes and was performed on MiSeq (Illumina, San Diego, USA).ResultsDisease-associated variants identified in 15 patients comprised 11 distinct heterozygous vWF gene variants in 13 patients and one novel FVIII gene variant (p.Glu2085Lys) in two male siblings. Four vWF variants were novel (p.Gln499Pro, p.Asp1277Tyr, p.Asp1277His, p.Lys1491Glu). Three patients without distinctive variants had vWF:GPIbM between 30 and 50%. Patients with identified vWF gene variants had statistically significant lower values of vWF:GPIbM (P = 0.002), vWF:Ag (P = 0.007), vWF:CBA (P < 0.001) and FVIII:C (P = 0.002), compared to those without. Correlations between BS and phenotypic laboratory test results were not statistically significant for either of the tests.ConclusionThe applied diagnostic approach confirmed the diagnosis of vWD in 13 patients and mild haemophilia A in two. Limited utility of BS in the paediatric population was evidenced.  相似文献   

10.
IntroductionIntensive physical activity causes functional and metabolic changes in the athlete’s organism. The study aimed to verify the common national available reference intervals (RIs) for common inflammatory and screening coagulation tests in a population of healthy young female athletes.Materials and methodsOne hundred and twenty-one female athletes (age range: 16–34), from various sports disciplines (water polo, handball, volleyball, football, basketball), were included in the study. All participants completed the international physical activity short-form questionnaire. Blood samples were collected between 8–10 am, after an overnight fast, before any physical activity. Reference intervals were determined according to Clinical & Laboratory Standards Institute EP28-A3C Guidelines.ResultsCalculated RIs for white blood cell count (WBC), prothrombin time (PT), and activated partial thromboplastin time (APTT) ratio were in accordance with the common national RIs. Calculated RI for C-reactive protein (CRP) was lower (< 2.9 mg/L) than the proposed cut-off for a healthy population (< 5.0 mg/L). Reference interval for fibrinogen was higher (1.9–4.4 g/L), than the available RIs (1.8–3.5 g/L). D-dimer cut-off value was set at 852 µg/L fibrinogen equivalent units (FEU), higher than the proposed 500 µg/L FEU for venous thromboembolism (VTE) exclusion.ConclusionsThe applicability of the available RIs for WBC count, PT, and APTT-ratio was confirmed. However, RIs for CRP and fibrinogen differed significantly than the available common national RIs for the healthy non-athletes’ population. A higher cut-off for D-dimers should be extensively verified before implementation for VTE diagnosis exclusion in a group of healthy young female athletes.  相似文献   

11.
Label-free isolation of single cells is essential for the growing field of single-cell analysis. Here, we present a device which prints single living cells encapsulated in free-flying picoliter droplets. It combines inkjet printing and impedance flow cytometry. Droplet volume can be controlled in the range of 500 pl–800 pl by piezo actuator displacement. Two sets of parallel facing electrodes in a 50 μm × 55 μm channel are applied to measure the presence and velocity of a single cell in real-time. Polystyrene beads with <5% variation in diameter generated signal variations of 12%–17% coefficients of variation. Single bead efficiency (i.e., printing events with single beads vs. total number of printing events) was 73% ± 11% at a throughput of approximately 9 events/min. Viability of printed HeLa cells and human primary fibroblasts was demonstrated by culturing cells for at least eight days.  相似文献   

12.
IntroductionEvaluation of thyroid function is often requested and therefore defining paediatric reference intervals (RIs) is of vital importance. Currently, there is a distinct lack of paediatric RIs for thyroid function tests in Croatia. Thus, we established RIs for thyroid stimulating hormone (TSH), total triiodothyronine (TT3), total thyroxine (TT4), free triiodothyronine (FT3) and free thyroxine (FT4) in the Croatian paediatric population.Materials and methodsReference intervals were calculated from 397 apparently healthy children, aged from 2 days to < 19 years. Serum samples were analysed for thyroid function tests on the Abbott Architect i2000. Age- and sex-specific 95% RIs with 90% confidence intervals were established according to Clinical and Laboratory Standards Institute guidelines. To express the magnitude of sex and age variation, standard deviation ratio (SDR) was calculated using two-level nested ANOVA. The criterion for considering partitioning reference values was set to SDR > 0.3.ResultsAll thyroid function tests required age partitioning, confirmed by SDR above 0.3. There was no need for sex partitioning, confirmed by SDR below 0.3. Still, FT3 was partitioned due to visually noticeable sex related difference for the oldest group (12 years to < 19 years).ConclusionThis is the first study to establish RIs for thyroid function tests in the Croatian paediatric population. We propose RIs for widely used Abbott platform, thus giving laboratories method- and population-specific paediatric RIs for thyroid function tests that should improve clinical test interpretation.  相似文献   

13.
The present study was designed to understand the cigarette smoking-induced alterations in hormones and the resulting changes in platelet serotonin (5-hydroxytryptamine, 5-HT) and monoamine oxidase (MAO-B) activity in chronic smokers. Human male volunteers aged 35 ± 8 years, were divided into two groups, namely controls and smokers (12 ± 2 cigarettes per day for 7–10 years). Results showed that cigarette smoking significantly (p < 0.05) elevated plasma triiodothyronine (T3), cortisol and testosterone levels with significant (p < 0.05) reduction in plasma tryptophan and thyroxin (T4). Moreover, smokers showed reduced platelet 5-HT levels and MAO-B activity. In smokers, plasma cortisol was negatively correlated with tryptophan (r = −0.386), platelet MAO-B (r = −0.264), and 5-HT (r = −0.671), and positively correlated with testosterone (r = 0.428). However, testosterone was negatively correlated with platelet MAO-B (r = −0.315), and 5-HT (r = −.419) in smokers. Further, smokers plasma T3 levels were negatively correlated with platelet MAO-B (r = −0.398), and 5-HT (r = −0.541), whereas T4 levels were positively correlated with platelet MAO-B (r = 0.369), and 5-HT (r = 0.454). In conclusion, our study showed that altered testosterone and cortisol levels may aggravate behavior, mood disturbances and symptoms of depression by decreasing platelet 5-HT and MAO-B activity in smokers.  相似文献   

14.
IntroductionFollowing a pandemic, laboratory medicine is vulnerable to laboratory errors due to the stressful and high workloads. We aimed to examine how laboratory errors may arise from factors, e.g., flexible working order, staff displacement, changes in the number of tests, and samples will reflect on the total test process (TTP) during the pandemic period.Materials and methodsIn 12 months, 6 months before and during the pandemic, laboratory errors were assessed via quality indicators (QIs) related to TTP phases. QIs were grouped as pre-, intra- and postanalytical. The results of QIs were expressed in defect percentages and sigma, evaluated with 3 levels of performance quality: 25th, 50th and 75th percentile values.ResultsWhen the pre- and during pandemic periods were compared, the sigma value of the samples not received was significantly lower in pre-pandemic group than during pandemic group (4.7σ vs. 5.4σ, P = 0.003). The sigma values of samples transported inappropriately and haemolysed samples were significantly higher in pre-pandemic period than during pandemic (5.0σ vs. 4.9σ, 4.3σ vs. 4.1σ; P = 0.046 and P = 0.044, respectively). Sigma value of tests with inappropriate IQC performances was lower during pandemic compared to the pre-pandemic period (3.3σ vs. 3.2σ, P = 0.081). Sigma value of the reports delivered outside the specified time was higher during pandemic than pre-pandemic period (3.0σ vs. 3.1σ, P = 0.030).ConclusionIn all TTP phases, some quality indicators improved while others regressed during the pandemic period. It was observed that preanalytical phase was affected more by the pandemic.  相似文献   

15.
A variety of methods have been used to introduce chemicals into a stream or to mix two or more streams of different compositions using microfluidic devices. In the following paper, the introduction of cryoprotective agents (CPAs) used during cryopreservation of cells in order to protect them from freezing injuries and increase viability post thaw is described. Dimethylsulphoxide (DMSO) is the most commonly used CPA. We aim to optimize the operating conditions of a two-stream microfluidic device to introduce a 10% vol/vol solution of DMSO into a cell suspension. Transport behavior of DMSO between two streams in the device has been experimentally characterized for a spectrum of flow conditions (0.7 < Re < 10), varying initial donor stream concentrations, (1% vol/vol < Co < 15% vol/vol) and different flow rate fractions (0.23 < fq < 0.77). The outlet cell stream concentration is analyzed for two different flow configurations: one with the cell stream flowing on top of the DMSO-rich donor stream, and the other with the cell stream flowing beneath the heavy DMSO-laden stream. We establish a transition from a diffusive mode of mass transfer to gravity-influenced convective currents for Atwood numbers (At) in the range of (1.7 × 10−3 < At < 3.1 × 10−3) for the latter configuration. Flow visualization with cells further our understanding of the effect of At on the nature of mass transport. Cell motion studies performed with Jurkat cells confirm a high cell recovery from the device while underscoring the need to collect both the streams at the outlet of the device and suggesting flow conditions that will help us achieve the target DMSO outlet concentration for clinical scale flow rates of the cell suspension.  相似文献   

16.
The quantum Hall effect (QHE) with quantized Hall resistance of h/νe2 started the research on topological quantum states and laid the foundation of topology in physics. Since then, Haldane proposed the QHE without Landau levels, showing nonzero Chern number |C| = 1, which has been experimentally observed at relatively low temperatures. For emerging physics and low-power-consumption electronics, the key issues are how to increase the working temperature and realize high Chern numbers (C > 1). Here, we report the experimental discovery of high-Chern-number QHE (C = 2) without Landau levels and C = 1 Chern insulator state displaying a nearly quantized Hall resistance plateau above the Néel temperature in MnBi2Te4 devices. Our observations provide a new perspective on topological matter and open new avenues for exploration of exotic topological quantum states and topological phase transitions at higher temperatures.  相似文献   

17.
IntroductionThe current study aimed to assess the interference of in vitro haemolysis on complete blood count (CBC) using Abbott Alinity hq system, and to determine which haemolysis levels affect the reliability of sample results.Materials and methodsBlood samples obtained from 25 volunteers in K3-EDTA tubes were divided into four aliquots. The first aliquot was not subjected to any intervention. The second, third and fourth aliquots were passed through a fine needle 2, 4 and 6 times, respectively. Complete blood count was performed by multi-angle polarized scatter separation technology and haemolysis index (HI) was assessed from the plasma samples separated by centrifugation. Five groups were formed according to the HI values. The percentage biases between the results of non-haemolysed and haemolysed groups were compared with the desirable bias limits from The European Federation of Clinical Chemistry and Laboratory Medicine database and reference change values (RCVs).ResultsIn groups 1 to 4, the effects of haemolysis on CBC parameters were acceptable comparing to the analytical bias except for lymphocytes (7.26%-7.42%), MCH (2.59%), and MCHC (0.47%-2.81%). Results of group 5 (gross haemolysis) showed decreases in HCT(- 4.56%), RBC (- 4.07%) count and increase in lymphocyte (11.60%) count higher than the analytical performance specifications. Moreover, variations in MCH (4.65%) and MCHC (5.24%) were exceeding the RCVs.ConclusionsGross haemolysis (haemoglobin concentration > 10 g/L) is likely to produce unreliable CBC results on non-pathological samples. Further studies including pathological specimens are needed.  相似文献   

18.
Human genetic adaptation to high altitudes (>2500 m) has been extensively studied over the last few years, but few functional adaptive genetic variants have been identified, largely owing to the lack of deep-genome sequencing data available to previous studies. Here, we build a list of putative adaptive variants, including 63 missense, 7 loss-of-function, 1,298 evolutionarily conserved variants and 509 expression quantitative traits loci. Notably, the top signal of selection is located in TMEM247, a transmembrane protein-coding gene. The Tibetan version of TMEM247 harbors one high-frequency (76.3%) missense variant, rs116983452 (c.248C > T; p.Ala83Val), with the T allele derived from archaic ancestry and carried by >94% of Tibetans but absent or in low frequencies (<3%) in non-Tibetan populations. The rs116983452-T is strongly and positively correlated with altitude and significantly associated with reduced hemoglobin concentration (p = 5.78 × 10−5), red blood cell count (p = 5.72 × 10−7) and hematocrit (p = 2.57 × 10−6). In particular, TMEM247-rs116983452 shows greater effect size and better predicts the phenotypic outcome than any EPAS1 variants in association with adaptive traits in Tibetans. Modeling the interaction between TMEM247-rs116983452 and EPAS1 variants indicates weak but statistically significant epistatic effects. Our results support that multiple variants may jointly deliver the fitness of the Tibetans on the plateau, where a complex model is needed to elucidate the adaptive evolution mechanism.  相似文献   

19.
20.
BackgroundTaraxacum species (commonly known as dandelion) used as herbal medicine have been reported to exhibit an antiproliferative effect on hepatoma cells and antitumor activity in non-small-cell lung cancer cells. Although several investigations have demonstrated the safety of Taraxacum officinale, the safety of tissue-cultured plants of T. formosanum has not been assessed so far. Therefore, the present study examines the safety of the water extract of the entire plant of tissue cultured T. formosanum based on acute and subacute toxicity tests in rats, as well as the Ames tests.ResultsNo death or toxicity symptoms were observed in the acute and subacute tests. The results of the acute test revealed that the LD50 (50% of lethal dose) value of the T. formosanum water extract for rats exceeded 5 g/kg bw. No abnormal changes in the body weight, weekly food consumption, organ weight, or hematological, biochemical, and morphological parameters were observed in the subacute toxicity test. Thus, the no observed adverse effect level (NOAEL) of T. formosanum water extract was estimated to be higher than 2.0 g/kg. Finally, the results of the Ames test revealed that T. formosanum water extract was not genotoxic at any tested concentration to any of five Salmonella strains.ConclusionsThe water extract of tissue-cultured T. formosanum was non-toxic to rats in acute and subacute tests and exhibited no genotoxicity to five Salmonella strains.How to cite: Tsai WC, Chang HC, Tseng YH, et al. Toxicity evaluation of water extract of tissue-cultured Taraxacum formosanum by acute, subacute administration, and Ames test. Electron J Biotechnol 2020;45. https://doi.org/10.1016/j.ejbt.2020.04.001  相似文献   