首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.

Introduction:

Non insulin dependent diabetes mellitus is the most common type of diabetes. Genetic factors, lipid profiles, hypertension are potential risk factors for diabetes mellitus. Adenosine binding cassette transporter proteins 1 (ABCA1) plays a role in cholesterol metabolism, especially high density lipoprotein (HDL-cholesterol). There are multiple mechanisms by which HDL-cholesterol can be atheroprotective, it is clear that the relative activity of ABCA1 plays a major role. We aimed to investigate association of ABCA1 C69T gene polymorphism with lipid levels in Turkish type 2 diabetic patients.

Materials and methods:

After isolation of DNA by ethanol precipitation we determined ABCA1 gene polymorphism by using polimerase chain reaction - restriction fragment lenght polymorphism (PCR-RFLP) method in 107 type 2 diabetic patients and 50 healthy controls.

Results:

We have observed that the frequency of TT genotype is significantly higher in healthy controls compared to patients (14% vs. 3%; P = 0.008). Also frequency of T allele was higher in controls than in patients (34% vs. 21%; P = 0.020; OR (95% CI) = 0.52 (0.30–0.88)). There was no association of lipid levels and ABCA1 C69T polymorphism subgroups.

Conclusion:

We have found significantly higher frequency of both T allele and genotype in control group when compared to patients that made us think that T allele may be a protective factor against diabetes mellitus. But, we could not find a relationship between genotypes and lipid concentrations in our two groups. Larger studies will help us to understand the relationship between ABCA1 C69T genotype and lipid parameters in diabetes mellitus.  相似文献   

2.

Background

Nonalcoholic fatty liver disease (NAFLD) is associated with the increased burden of kidney. However, there is still no large population study to explore the potential relationship between NAFLD and mild kidney function damage (MKFD) after adjusted for confounding factors. This study is to test the hypothesis that NAFLD is associated with MKFD under controlling the effects of confounding factors.

Materials and methods:

Levels of serum fasting glucose, creatinine, cholesterol, triglyceride, alanine aminotransferase and aspartate aminotransferase were analyzed from 1412 Chinese Han adults. Questionnaire and physical examination were performed to explore the potential association of NAFLD with kidney function.

Results:

NAFLD was associated with impairment of kidney function. Multivariate-adjusted odds ratio illustrated that, compared to subjects with normal liver, NAFLD subjects had a significantly higher risk of MKFD with or without adjusted for blood glucose and other covariates (P = 0.041). Further results from multi-interaction analysis demonstrated that the underlying mechanisms linked NAFLD with impaired kidney function may be that they share common risk factors and similar pathological processes.

Conclusions:

The most striking finding of this study is that NAFLD is negatively associated with kidney function, in nondiabetic population. NAFLD and MKFD may share similar risk factors and/or pathological processes.  相似文献   

3.

Introduction:

Proper preparation of the individual is a key prerequisite for ensuring the quality of laboratory testing. Our hypothesis was that many outpatients are not sufficiently familiar with the correct way of preparing for the laboratory tests, for which the individual needs to be at fasting. This study aimed to investigate: i) whether patients are aware of how they need to prepare properly for laboratory tests; ii) the way in which users are informed about how to prepare for laboratory testing; and iii) whether users arrive to the laboratory for phlebotomy properly prepared.

Materials and methods:

An anonymous questionnaire was conducted on 150 outpatients older than 18 years, during February 2013. The response rate was 11%. All patients were interviewed by the laboratory staff. Patients were informed about detail of the questionnaire and agreed to participate in the survey.

Results:

Out of the total number subjects, 39% were fully aware of the proper definition of the fasting, whereas even 46% subjects replied that the last meal has to be taken the day before and the exact time that must pass after the last meal to blood sampling is not important. Furthermore, 52% subjects did not receive any information about how they need to prepare themselves properly for blood testing. Only 60% of them came properly prepared for the laboratory blood testing.

Conclusions:

Substantial proportion of patients do not come properly prepared for laboratory testing. We conclude that patients are not well informed about the fasting requirements for laboratory blood testing. Moreover, requesting physician is the preferred source of information from which patients learn how to prepare themselves for phlebotomy.  相似文献   

4.

Introduction:

Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory.

Materials and methods:

This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors.

Results:

A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients.

Conclusions:

The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.  相似文献   

5.

Background:

Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests.

Materials and methods:

A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV).

Results:

A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104–117) and 111 (107–120) vs. 109 (102–118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9–34.8) vs. 34.1 (32.2–35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV.

Conclusion:

A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.  相似文献   

6.

Introduction

To study the pre-design and success of a strategy based on the addition of hemoglobin A1c (HbA1c) in the blood samples of certain primary care patients to detect new cases of type 2 diabetes.

Materials and methods

In a first step, we retrospectively calculated the number of HbA1c that would have been measured in one year if HbA1c would have been processed, according to the guidelines of the American Diabetes Association (ADA). Based on those results we decided to prospectively measure HbA1c in every primary care patient above 45 years, with no HbA1c in the previous 3 years, and glucose concentration between 5.6-6.9 mmol/L, during an 18 months period. We calculated the number of HbA1c that were automatically added by the LIS based on our strategy, we evaluated the medical record of such subjects to confirm whether type 2 diabetes was finally confirmed, and we calculated the cost of our intervention.

Results

In a first stage, according to the guidelines, Hb1Ac should have been added to the blood samples of 13,085 patients, resulting in a cost of 14,973€. In the prospective study, the laboratory added Hb1Ac to 2092 patients, leading to an expense of 2393€. 314 patients had an HbA1c value ≥ 6.5% (48 mmol/mol). 82 were finally diagnosed as type 2 diabetes; 28 thanks to our strategy, with an individual cost of 85.4€; and 54 due to the request of HbA1c by the general practitioners (GPs), with a cost of 47.5€.

Conclusion

The automatic laboratory-based strategy detected patients with type 2 diabetes in primary care, at a cost of 85.4€ per new case.Key words: type 2 diabetes, HbA1c, diagnosis, preanalytical phase, test request appropriateness, costs, cost analysis  相似文献   

7.

Introduction:

Heavy chain diseases (HCD) are neoplastic proliferations of B cells which secrete truncated immunoglobulin heavy chains without associated light chains. Being rare and probably underdiagnosed diseases the aim of this report is to show an additional case of gamma heavy chain disease in a 48 year old female patient with rheumatoid arthritis focusing on the laboratory presentation.

Materials and methods:

Laboratory work-up included agarose gel electrophoresis (AGE), capillary zone electrophoresis (CZE), immunofixation and nephelometrically determined immunoglobulin and immunoglobulin subclasses of the patient’s serum. Urine samples were also subjected to immunofixation and to a SDS-PAGE with consecutive immunoblot.

Results:

Nephelometrically measured elevated IgG concentrations were noted in combination with a decreased gamma globulin region and an increased beta globulin region on AGE. A definite monoclonal spike was not identified on AGE but at least suspected on CZE; finally serum and urine immunofixation demonstrated a monoclonal gamma heavy chain devoid of any corresponding light chains confirming the diagnosis of HCD. Analysis of the gamma heavy chain (HC) with means of SDS-PAGE revealed proteins of 40 kD and 80 kD most likely presenting a truncated HC in its monomeric and dimeric form and possibly leading to the failure of IgG-subclass typing with the applied IgG subclass antisera.

Conclusion:

This case report illustrates a new case of gamma HCD demonstrating variable laboratory manifestations and therefore the need for heightened awareness concerning this disease when confronted with abnormal and discrepant protein profiles in routinely applied laboratory tests.  相似文献   

8.

Introduction:

We present our work of monitoring 202 different patients with markedly elevated serum index for lipemia whereby serum samples were clear. We tried to clarify the cause of occurrence of these indices which were detected in the years 2006–2010 on Siemens Dimension analyzers.

Materials and methods:

In samples with unusual lipemia index we measured the concentration of lipids (total cholesterol, triglycerides, HDL and LDL cholesterol, Lp(a), ApoA1, ApoB), total proteins and checked for possible interferents (rheumatoid factor, immunoglobulins). We performed serum protein and immuno- electrophoresis. We investigated the repeatability of unusual lipemia indices during the day and after different time periods and we compared them on four different analyzers (RXL Max, Vista, Hitachi 911 and former Olympus AU640).

Results:

In 87% of 202 samples we found a monoclonal or biclonal peak in serum protein electrophoresis. Different types of paraproteins were confirmed with immunofixation electrophoresis. In the remaining 13%, polyclonal elevated concentrations of immunoglobulins were measured. Other parameters had no influence on appearing of these indices. The repeatability of indices was good during the first day of measurements (P values > 0.05) and markedly lower in the next days or after 3 and 12 months (P values < 0.05). The indices were elevated only on Dimension analyzers, but not on Hitachi and former Olympus analysers.

Conclusion:

A markedly elevated lipemia index in a clear serum sample measured on Siemens analyzers Dimension indicates a high possibility for the presence of a paraprotein in the sample.  相似文献   

9.

Introduction:

Zonulin is a eukaryotic protein structurally similar to Vibrio cholerae’s zonula occludens toxin. It plays an important role in the opening of small intestine tight junctions. The loss of gut wall integrity during sepsis might be pivotal and has been described in various experimental as well as human studies. Increased levels of zonulin could be demonstrated in diseases associated with increased intestinal inflammation, such as celiac disease and type 1 diabetes. We therefore investigated the role of plasma levels of zonulin in patients with sepsis as a non-invasive marker of gut wall integrity.

Materials and methods:

Plasma level of zonulin was measured in 25 patients with sepsis, severe sepsis or septic shock according to ACCP/SCCM criteria at the first day of diagnosed sepsis. 18 non-septic post-surgical ICU-patients and 20 healthy volunteers served as control. Plasma levels were determined by using commercially available ELISA kit. Data are given as median and interquartile range (IQR).

Results:

Significantly higher plasma concentration of zonulin were found in the sepsis group: 6.61 ng/mL (IQR 3.51–9.46), as compared to the to the post-surgical control group: 3.40 ng/mL (IQR 2.14–5.70) (P = 0.025), as well as to the healthy group: 3.55 ng/mL (IQR 3.14–4.14) (P = 0.008).

Conclusion:

We were able demonstrate elevated levels of plasma zonulin, a potential marker of intestinal permeability in septic patients. Increased zonulin may serve as an additional mechanism for the observed increased intestinal permeability during sepsis and SIRS.  相似文献   

10.

Introduction:

The aim of this study was to investigate whether serum levels of interleukin-1β (IL–1β) has any possible correlation on inflammatory parameters such as C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and fibrinogen concentration in patients with familial Mediterranean fever (FMF) patients during attack-free period.

Materials and methods:

The serum levels of IL-1β, as an indicator of cytokines status, and the acute phase response proteins, CRP, ESR and fibrinogen levels were evaluated in 35 attack-free patients with FMF and 25 healthy volunteers.

Results:

Serum IL-1β levels were significantly higher in patients with FMF than control subjects (P = 0.018). There was no statistically significant difference in the serum levels of ESR, CRP and fibrinogen between two groups (P = 0.181, P = 0.816, P = 0.686, respectively). There was a significant correlation between IL-1β and CRP (r = 0.513, P = 0.002) values of FMF group.

Conclusions:

In conclusion, our results confirm the presence of increased IL-1β levels in FMF patients during attack-free period. Serum IL-1β values seems to correlate with CRP levels. The elevation of IL-1β levels may be important in monitoring subclinical inflammation of attack free period in FMF patients.  相似文献   

11.

Introduction:

Studies about vitamin D [25(OH)D] stability in plasma are limited and preanalytical variables such as tube type may affect results. We aimed to evaluate effect of storage conditions, sample type and some preanalytical variables on vitamin D concentration.

Materials and methods:

Blood samples from 15 healthy subjects were centrifuged at different temperatures and stored under different conditions. Serum and plasma 25(OH)D difference, effect of centrifugation temperature and common storage conditions were investigated.

Results:

There was no difference between serum and plasma vitamin D concentration. Centrifugation temperature had no impact on vitamin D concentration. 25(OH)D is stable under common storage conditions: 4 hours at room temperature, 24 hours at 2–8 °C, 7 days at −20 °C, 3 months at −80 °C.

Conclusion:

Vitamin D does not require any special storage conditions and refrigeration. Both serum and plasma can be used for measurement.  相似文献   

12.

Introduction

Vaspin (visceral adipose tissue-derived serpin) was first described as an insulin-sensitizing adipose tissue hormone. Recently its anti-inflammatory function has been demonstrated. Since no appropriate data is available yet, we sought to investigate the plasma concentrations of vaspin in sepsis.

Materials and methods

57 patients in intensive care, fulfilling the ACCP/SCCM criteria for sepsis, were prospectively included in our exploratory study. The control group consisted of 48 critically ill patients, receiving intensive care after trauma or major surgery. Patients were matched by age, sex, weight and existence of diabetes before statistical analysis. Blood samples were collected on the day of diagnosis. Vaspin plasma concentrations were measured using a commercially available enzyme-linked immunosorbent assay.

Results

Vaspin concentrations were significantly higher in septic patients compared to the control group (0.3 (0.1-0.4) ng/mL vs. 0.1 (0.0-0.3) ng/mL, respectively; P < 0.001). Vaspin concentration showed weak positive correlation with concentration of C-reactive protein (CRP) (r = 0.31, P = 0.002) as well as with SAPS II (r = 0.34, P = 0.002) and maximum of SOFA (r = 0.39, P < 0.001) scoring systems, as tested for the overall study population.

Conclusion

In the sepsis group, vaspin plasma concentration was about three-fold as high as in the median surgical control group. We demonstrated a weak positive correlation between vaspin and CRP concentration, as well as with two scoring systems commonly used in intensive care settings. Although there seems to be some connection between vaspin and inflammation, its role in human sepsis needs to be evaluated further.Key words: adipocytokine, inflammation, vaspin, CRP, intensive care  相似文献   

13.

Introduction

The aim of the study was to present a protocol for laboratory information system (LIS) and hospital information system (HIS) validation at the Institute of Clinical Chemistry and Laboratory Medicine of the Merkur University Hospital, Zagreb, Croatia.

Materials and methods:

Validity of data traceability was checked by entering all test requests for virtual patient into HIS/LIS and printing corresponding barcoded labels that provided laboratory analyzers with the information on requested tests. The original printouts of the test results from laboratory analyzer(s) were compared with the data obtained from LIS and entered into the provided template. Transfer of data from LIS to HIS was examined by requesting all tests in HIS and creating real data in a finding generated in LIS. Data obtained from LIS and HIS were entered into a corresponding template. The main outcome measure was the accuracy of transfer obtained from laboratory analyzers and results transferred from LIS and HIS expressed as percentage (%).

Results:

The accuracy of data transfer from laboratory analyzers to LIS was 99.5% and of that from LIS to HIS 100%.

Conclusion:

We presented our established validation protocol for laboratory information system and demonstrated that a system meets its intended purpose.  相似文献   

14.

Background

It is still uncertain whether or not avoidance to let disinfectant alcohol dry at the site of venipuncture is a source of spurious hemolysis when drawing venous blood.

Methods:

In a consecutive series of 52 outpatients referred for routine laboratory testing, venous blood was drawn by direct venipuncture with (odd group) or without (pair group) wiping 70% isopropyl alcohol at the site of venipuncture. A 3.5 mL evacuated tube with clot activator and gel separator was drawn from a vein of the upper limb, serum was immediately separated with standard centrifugation and tested for potassium, lactate dehydrogenase (LD), aspartate aminotransferase (AST) and hemolysis index (HI) on Roche Cobas.

Results:

No specimen was discarded for unsatisfactory venipuncture. No differences for age and gender were observed between groups. As regards the four parameters investigated, no significant differences could be observed between patients in whom blood was drawn with or without letting the alcohol dry. It is also noteworthy that no sample in both groups exceeded the conventional sample rejection threshold of cell-free hemoglobin.

Conclusions:

The results of our prospective, randomized study attest that failure to wipe alcohol at the site of venipuncture should not be considered as a potential source of spurious hemolysis when drawing blood.  相似文献   

15.

Introduction

Glycosylated hemoglobin (HbA1c) concentrations measured in clinical chemistry laboratories show large differences between their interlaboratory reported values. Laboratory measurements of quality performance should be based on quantitative data. The sigma metrics model provides an objective method for the assessment of current HbA1c assays and is useful in quality management planning. The aim of our study was to evaluate the analytical performance of the MQ-2000 PT HbA1c analyzer test results in the context of our operating conditions on the sigma scale.

Materials and methods

The coefficient of variation was determined from the calculated mean and standard deviation evaluated from internal quality control (QC) (N = 168 days) (Shanghai Huachen Biological Reagent Co. Ltd, China) data, and records of external quality data (KBUDEK, İstanbul, Turkey) measured in the period from May to November 2013 were used to determine the bias. The resulting data and total allowable error rate (TEA = 10%) from the Clinical Laboratory Improvement Amendments of 1988 (CLIA’88) were used to calculate the sigma level.

Results

The calculated coefficient of variations (CVs) at the two levels, normal (QC1 = 36.6 ± 2.38 mmol/mol) and pathological (QC2 = 84.7 ± 2.68 mmol/mol), were 6.5% and 3.1%, respectively. The average bias between the external QC and MQ-2000 PT during the study period was 4.3%. The calculated average sigma value was 1.19.

Conclusions

The MQ-2000 PT HbA1c is a new analyser in the market; there is need for improvement and the method should be controlled with greater attention to ensure quality.Key words: diabetes mellitus, hemoglobin A1c protein, human, chromatography, high pressure liquid chromatography  相似文献   

16.

Introduction

Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L.

Materials and methods

Baseline (group I) serum pool with glucose concentration of 5.55 (5.44-5.61) mmol/L was prepared from patient sera. Spiking with 20% dextrose solution, sample groups were obtained with glucose concentrations: 17.09, 34.52, and 50.95 mmol/L (group II, III, IV, respectively). Total of 21 biochemistry analytes and thyroid tests were studied on Abbott c8000 and i2000sr with commercial reagents. Bias from baseline value was checked statistically and clinically.

Results

Creatinine increased significantly by 8.74%, 31.66%, 55.31% at groups II, III, IV, respectively with P values of < 0.001. At the median glucose concentration of 50.95 mmol/L, calcium, albumin, chloride and FT4 biased significantly clinically (-0.85%, 1.63%, 0.65%, 7.4% with P values 0.138, 0.214, 0.004, < 0.001, respectively). Remaining assays were free of interference.

Conclusion

Among the numerous biochemical parameters studied, only a few parameters are affected by dramatically increased glucose concentration. The creatinine measurements obtained in human sera with the Jaffe alkaline method at high glucose concentrations should be interpreted with caution. Other tests that were affected with extremely high glucose concentrations were calcium, albumin, chloride and FT4, hence results should be taken into consideration in patients with poor diabetic control.Key words: assay interference, glucose interference, preanalytical phase, creatinine, Jaffe kinetic assay, thyroid function tests  相似文献   

17.

Introduction

The aim of this study was to identify clinical variables which may be independently associated with positivity of a cardiac troponin I (cTnI) assay in a large population of patients admitted to the emergency department (ED).

Materials and methods

3166 subjects, with at least two troponin I tests ordered within 6 hours in the ED, were studied. Patient data were statistically analyzed to identify clinical associations with increased values of Troponin I.

Results

Although patients with diagnosis of acute coronary syndrome displayed troponin I values significantly higher than those of other groups, positivity to troponin I (> 40 ng/L) was also observed in patients with other clinical conditions. In multivariate analysis, age, elevated heart rate and electrocardiographyc changes were independently associated with troponin I positivity at admission. In the whole study population troponin I positivity exhibited high sensitivity and negative predictive value, counterbalanced by low specificity and limited positive predictive value.

Conclusions

Troponin I positivity should be combined with history and clinical evaluation and cautiously interpreted in the ED, especially in patients exhibiting factors associated with higher troponin I levels such as older age, elevated heart rate or ECG changes.Key words: troponin I, acute coronary syndrome, emergency service, hospital, chest pain  相似文献   

18.

Introduction

The study was performed to compare and analyze the inter-departmental variability in the request of rarely requested laboratory tests in primary care, as opposed to other more common and highly requested tests.

Materials and methods

Data from production statistics for the year 2012 from 76 Spanish laboratories was used. The number of antinuclear antibodies, antistreptolysin O, creatinine, cyclic citrullinated peptide antibodies, deaminated peptide gliadine IgA antibodies, glucose, protein electrophoresis, rheumatoid factor, transglutaminase IgA antibodies, urinalysis and uric acid tests requested was collected. The number of test requests per 1000 inhabitants was calculated. In order to explore the variability the coefficient of quartile dispersion was calculated.

Results

The smallest variation was seen for creatinine, glucose, uric acid and urinalysis; the most requested tests. The tests that were least requested showed the greatest variability.

Conclusion

Our study shows through a very simplified approach, in a population close to twenty million inhabitants, how in primary care, the variability in the request of laboratory tests is inversely proportional to the request rate.Key words: primary care, laboratory proficiency testing, clinical laboratory services, test requesting, preanalytical phase  相似文献   

19.

Introduction

Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC).

Materials and methods

We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square.

Results

There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients.

Conclusion

We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system.Key words: Preanalytical phase, errors in laboratory medicine, balanced scorecard, patient safety  相似文献   

20.

Introduction

Gentamicin due to its low level of resistance and rapid bactericidal activity is commonly used to treat gram-negative bacteria. However, due to its toxic effects it needs to be monitored. To date, no interference has been reported with gentamicin assays.

Materials and methods

A patient with leg cellulitis and sepsis received a single dose of gentamicin and a sample was sent for gentamicin analysis. The sample showed high blank absorbance readings on Beckman DxC800 and DC800 analysers with various dilutions. A second sample was received and analysed on a Roche Cobas system to obtain a result. A third sample was received 107 hours later with the same results and this sample was then analysed neat and post ethanol precipitation on all the turbidimetric assays available on the DxC800 analyser.

Results

The high blank absorbance was observed upon addition of the reactive reagents due to protein precipitation. Although not obvious from the patient protein results, it was shown the presence of high IgM paraprotein, 18.9 g/L (reference range 0.4-2.3 g/L) was the cause of precipitation, giving high blank readings. Of all the other turbidimetric assays, only vancomicin and valproate showed similar high blank absorbance readings. To be able to provide more rapid results it was shown ethanol could be used as a precipitant of proteins in both calibrators and patient samples with acceptable recovery.

Conclusion

IgM paraprotein was identified as the cause of interference with the gentamicin, vancomicin and valproate assays. Protein interference in these assays can be overcome by precipitation with ethanol.Key words: turbidimetry, IgM, paraprotein, interference  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号