首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
IntroductionSeveral laboratory tests are characteristically altered in Coronavirus Disease 2019 (COVID-19), but are not totally accurate in predicting the disease outcome. The long pentraxin 3 (PTX3) is quickly released directly at inflammation sites by many immune cell types. Previous studies have shown that PTX3 correlated with disease severity in various inflammatory conditions. Our study investigated the use of PTX3 as a potential marker of COVID-19 severity and compared its performance in detecting a more severe form of the disease with that of routine laboratory parameters.Materials and methodsStored serum samples of RT-PCR confirmed COVID-19 cases that had been obtained at hospital admission were retrospectively analysed. Intensive care unit (ICU) stay was considered a surrogate endpoint of severe COVID-19. Pentraxin 3 was measured by a commercial enzyme-linked immunosorbent assay.ResultsA total of 96 patients were recruited from May 1st, 2020 to June 30th, 2020; 75/96 were transferred to ICU. Pentraxin 3 was higher in ICU vs non-ICU patients (35.86 vs 10.61 ng/mL, P < 0.001). Univariate and multivariate logistic regression models demonstrated that the only significant laboratory predictor of ICU stay was PTX3 (OR: 1.68 (1.19-2.29), P = 0.003), after controlling for comorbidities. The Receiver Operator Characteristic curve analysis showed that PTX3 had a higher accuracy compared to C-reactive protein (CRP), lactate dehydrogenase (LD), ferritin in identifying ICU patients (AUC of PTX3 = 0.98; CRP = 0.66; LD = 0.70; ferritin = 0.67, P < 0.001). A cut-off of PTX3 > 18 ng/mL yielded a sensitivity of 96% and a specificity of 100% in identifying patients requiring ICU.ConclusionHigh values of PTX3 predict a more severe COVID-19.  相似文献   

2.
IntroductionIntensive physical activity causes functional and metabolic changes in the athlete’s organism. The study aimed to verify the common national available reference intervals (RIs) for common inflammatory and screening coagulation tests in a population of healthy young female athletes.Materials and methodsOne hundred and twenty-one female athletes (age range: 16–34), from various sports disciplines (water polo, handball, volleyball, football, basketball), were included in the study. All participants completed the international physical activity short-form questionnaire. Blood samples were collected between 8–10 am, after an overnight fast, before any physical activity. Reference intervals were determined according to Clinical & Laboratory Standards Institute EP28-A3C Guidelines.ResultsCalculated RIs for white blood cell count (WBC), prothrombin time (PT), and activated partial thromboplastin time (APTT) ratio were in accordance with the common national RIs. Calculated RI for C-reactive protein (CRP) was lower (< 2.9 mg/L) than the proposed cut-off for a healthy population (< 5.0 mg/L). Reference interval for fibrinogen was higher (1.9–4.4 g/L), than the available RIs (1.8–3.5 g/L). D-dimer cut-off value was set at 852 µg/L fibrinogen equivalent units (FEU), higher than the proposed 500 µg/L FEU for venous thromboembolism (VTE) exclusion.ConclusionsThe applicability of the available RIs for WBC count, PT, and APTT-ratio was confirmed. However, RIs for CRP and fibrinogen differed significantly than the available common national RIs for the healthy non-athletes’ population. A higher cut-off for D-dimers should be extensively verified before implementation for VTE diagnosis exclusion in a group of healthy young female athletes.  相似文献   

3.
IntroductionTotal bilirubin tests are highly demanded in clinical laboratories. Since icteric index (I-index) has zero cost, we aimed to evaluate its clinical utility and cost-effectiveness to determine if total bilirubin is necessary to be tested. We took into account if haemolysis could interfere to icteric index determination.Material and methodsRetrospectively we reviewed I-index results in two cohorts (43,372 and 8507 non-haemolysed and haemolysed samples, respectively). All determinations were done using Alinity c chemistry analysers (Abbott Diagnostics). Receiver operating characteristic (ROC) curve was used to determine the optimal index cut-off to discriminate between normal and abnormal bilirubin concentration (20.5 µmol/L).ResultsThe ROC curve analysis suggested 21.4 µmol/L as the optimal I-index cut-off but differences in sensitivity and specificity were detected between patient derivation. For rejecting purpose, 15.4 µmol/L and 17.1 µmol/L I-index thresholds were selected based on patient derivation (inpatients and emergency room; and primary care and outpatients, respectively) with 97% sensitivity and 0.25% false negative results. Sensitivity was much lower in haemolysed samples. We selected 34.2 µmol/L I-index as threshold to detect hyperbilirubinemia with 99.7% specificity and 0.26% false positive results, independent of haemolysis. With the icteric index cut-offs proposed, we would save 66% of total bilirubin requested and analyse total bilirubin in around 2% of samples without total bilirubin requested.ConclusionsThis study supports the use of I-index to avoid bilirubin determination and to identify patients with hyperbilirubinemia. This work considers that the economic and test savings could help to increase the efficiency in clinical laboratories.  相似文献   

4.

Introduction:

Respiratory syncytial virus (RSV) infection is the most common cause of hospitalization in infants and small children. The aim was to present a 13-months old boy diagnosed with acute airway infection, acute otitis media (AOM) and hepatitis during the RSV-infection.

Material and methods:

Serum catalytic activities of alkaline phosphatase (ALP), aspartate aminotranspherase (AST), alanine aminotranspherase (ALT), gamma glutamyl transpherase (GGT), lactate dehydrogenase (LD), and concentrations of bilirubin were monitored during hospitalization and at control examination.

Results:

The child had clinical signs and symptoms of respiratory failure, AOM, and laboratory findings of virus infection and liver disease. On admission, catalytic activities of enzymes were markedly increased, especially the activity of ALP (10333 U/L, i.e. 24-fold increase in comparison with the upper reference limit). The highest increased in AST (339 U/L, 4.5-fold), ALT (475 U/L, 10.3-fold) and LD (545 U/L, 1.5-fold) were registered on the 3rd day, and the highest increase in GGT (68 U/L, 3.1-fold) occurred on the 11th day. Seven weeks after discharge AST, ALT, GGT and LD decreased into reference range, and ALP remain mildly increased (478 U/L, 1.1 fold increase). RSV was confirmed in nasal lavage fluid.

Conclusion:

Laboratory results in patient with RSV infection needs to be interpreted in the light of both, respiratory and extrapulmonary manifestations of the infection, respectively.  相似文献   

5.
IntroductionIndirect estimation of reference intervals (RIs) is straightforward and inexpensive procedure for determination of intra-laboratory RIs. We applied the indirect approach to assess RIs for haematological parameters in capillary blood of pre-school children, using results stored in our laboratory database.Materials and methodsWe extracted data from laboratory information system, for the results obtained by automatic haematology analyser in capillary blood of 154 boys and 146 girls during pre-school medical examination. Data distribution was tested, and logarithmic transformation was applied if needed. Reference intervals were calculated by the nonparametric percentile method.ResultsReference intervals were calculated for: RBC count (4.2-5.4 x1012/L), haemoglobin (114-146 g/L), MCH (25.0-29.4 pg), MCHC (321-368 g/L), RDW-SD (36.1-43.5 fL), WBC count (4.5-12.3 x109/L), neutrophils count (1.7-6.9 x109/L) and percentage (29.0-69.0%), lymphocytes count (1.6-4.4 x109/L) and percentage (21.9-60.7%), PLT (165-459 x109/L), MPV (8.1-11.4 fL) and PDW (9.2-14.4%). Gender specific RIs were calculated for monocytes count (male (M): 0.2-1.6 x109/L; female (F): 0.1-1.4 x109/L) and percentage (M: 2.5-18.3%; F: 1.8-16.7%), haematocrit (M: 0.34-0.42 L/L; F: 0.34-0.43 L/L), MCV (M: 73.4-84.6 fL; F: 75.5-84.2 fL) and RDW (M: 12.1-14.3%; F: 11.7-13.9%), due to observed gender differences in these parameters (P = 0.031, 0.028, 0.020, 0.012 and 0.001; respectively). Estimated RIs markedly varied from the literature based RIs that are used in the laboratory.ConclusionsIndirect method employed in this study enables straightforward assessment of RIs in pre-school children. Herein derived RIs differed from the literature-based ones, indicating the need for intra-laboratory determination of RIs for specific populations and sample types.  相似文献   

6.
IntroductionEffective implementation and continual compliance with ISO 15189:2012 require ongoing commitment and active involvement of laboratory staff. Our aim was to assess attitudes regarding accreditation implementation by conducting a survey in three Croatian accredited medical laboratories.Materials and methodsAn anonymous survey consisting of 34 questions was distributed either electronically or in a paper form a week prior to scheduled annual audits. Distributions of answers regarding age, work experience, laboratory workplace, and education level and according to the respective laboratory were compared.ResultsThe overall response rate was 76% (225/297). Preference towards working in an accredited laboratory and a positive attitude were revealed by 70% and 56% participants, respectively, with better process documentation as the main advantage. Only 14% of responders considered themselves completely familiar with ISO 15189:2012. Total of 68% of responders felt that accreditation increases the usual workload, with excessive paperwork as the main contributor. Half of the responders declared partial agreement that accreditation requirements and expectations were clearly explained and claimed that their suggestions were taken into account only occasionally, which was especially emphasized by technical staff. The vast majority (89%) completely follow the prescribed protocols. Only 27% consider turnaround time monitoring useful. Competence assessment is considered efficient by 41% of responders. The majority (73%) prefer an online audit in times of COVID-19.ConclusionsDespite an overall positive attitude towards accreditation, further efforts are needed in providing better education about ISO 15189:2012 for technical staff and modifying formats of competence assessment, in order to achieve better adherence to ISO 15189:2012 requirements.  相似文献   

7.
IntroductionThe COVID-19 pandemic has posed several challenges to clinical laboratories across the globe. Amidst the outbreak, errors occurring in the preanalytical phase of sample collection, transport and processing, can further lead to undesirable clinical consequences. Thus, this study was designed with the following objectives: (i) to determine and compare the blood specimen rejection rate of a clinical laboratory and (ii) to characterise and compare the types of preanalytical errors between the pre-pandemic and the pandemic phases.Materials and methodsThis retrospective study was carried out in a trauma-care hospital, presently converted to COVID-19 care centre. Data was collected from (i) pre-pandemic phase: 1st October 2019 to 23rd March 2020 and (ii) pandemic phase: 24th March to 31st October 2020. Blood specimen rejection rate was calculated as the proportion of blood collection tubes with preanalytical errors out of the total number received, expressed as percentage.ResultsTotal of 107,716 blood specimens were screened of which 43,396 (40.3%) were received during the pandemic. The blood specimen rejection rate during the pandemic was significantly higher than the pre-pandemic phase (3.0% versus 1.1%; P < 0.001). Clotted samples were the commonest source of preanalytical errors in both phases. There was a significant increase in the improperly labelled samples (P < 0.001) and samples with insufficient volume (P < 0.001), whereas, a significant decline in samples with inadequate sample-anticoagulant ratio and haemolysed samples (P < 0.001).ConclusionIn the ongoing pandemic, preanalytical errors and resultant blood specimen rejection rate in the clinical laboratory have significantly increased due to changed logistics. The study highlights the need for corrective steps at various levels to reduce preanalytical errors in order to optimise patient care and resource utilisation.  相似文献   

8.
IntroductionCoronavirus disease 2019 (COVID-19) is known to induce robust antibody response in most of the affected individuals. The objective of the study was to determine if we can harvest the test sensitivity and specificity of a commercial serologic immunoassay merely based on the frequency distribution of the SARS-CoV-2 immunoglobulin (Ig) G concentrations measured in a population-based seroprevalence study.Materials and methodsThe current study was conducted on a subset of a previously published dataset from the canton of Geneva. Data were taken from two non-consecutive weeks (774 samples from May 4-9, and 658 from June 1-6, 2020). Assuming that the frequency distribution of the measured SARS-CoV-2 IgG is binormal (an educated guess), using a non-linear regression, we decomposed the distribution into its two Gaussian components. Based on the obtained regression coefficients, we calculated the prevalence of SARS-CoV-2 infection, the sensitivity and specificity, and the most appropriate cut-off value for the test. The obtained results were compared with those obtained from a validity study and a seroprevalence population-based study.ResultsThe model could predict more than 90% of the variance observed in the SARS-CoV-2 IgG distribution. The results derived from our model were in good agreement with the results obtained from the seroprevalence and validity studies. Altogether 138 of 1432 people had SARS-CoV-2 IgG ≥ 0.90, the cut-off value which maximized the Youden’s index. This translates into a true prevalence of 7.0% (95% confidence interval 5.4% to 8.6%), which is in keeping with the estimated prevalence of 7.7% derived from our model. Our model can provide the true prevalence.ConclusionsHaving an educated guess about the distribution of test results, the test performance indices can be derived with acceptable accuracy merely based on the test results frequency distribution without the need for conducting a validity study and comparing the test results against a gold-standard test.  相似文献   

9.
10.
IntroductionThe data on the coronavirus disease (COVID-19) in solid-organ transplant recipients (SOTRs) in Croatia is unknown. The aim of this study was to analyze the seroprevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in Croatian SOTRs.Materials and methodsFrom 7 September to 27 November 2020 (beginning of the second COVID-19 pandemic wave), a cross-sectional screening for COVID-19 was performed in the adult outpatient liver (LTRs; N = 280) and kidney transplant recipients (KTRs; N = 232). Serum samples were initially tested for SARS-CoV-2 IgG antibodies using a commercial enzyme-linked immunosorbent assay (ELISA; Vircell Microbiologists, Granada, Spain). All positive samples were confirmed using a virus neutralization test (VNT). Data on risk exposure and COVID-19 related symptoms were collected using a questionnaire.ResultsThe transplanted cohort’s seroprevalence detected by ELISA and VNT was 20.1% and 3.1%, respectively. Neutralizing (NT) antibodies developed in 15.6% of anti-SARS-CoV-2 ELISA IgG positive SOTRs. The difference in seropositivity rates between LTRs and KTRs was not statistically significant (ELISA 21.1% vs. 19.0%, P = 0.554; VNT 3.6% vs. 2.6%, P = 0.082). Overall VNT positivity rates were higher in patients who reported participation in large community events (5.9% vs. 1.0%; P = 0.027) as well as in patients who reported COVID-19 related symptoms in the past six months. In addition, symptomatic VNT positive patients showed significantly higher (P = 0.031) NT antibody titers (median 128, interquartile range (IQR) = 32-128) compared to asymptomatic patients (median 16, IQR = 16-48).ConclusionsThis study showed that 15.6% of anti-SARS-CoV-2 ELISA positive Croatian SOTRs developed NT antibodies indicating protective immunity. Further studies are needed to determine the dynamic of NT antibodies and COVID-19 immunity duration in immunocompromised populations such as LTRs and KTRs.  相似文献   

11.
IntroductionLeukolysis-related pseudohyperkalemia due to preanalytical procedures may lead to erroneous (or absence of) treatment based on an invalid lab test result. We aimed to obtain a leukocyte threshold above which leukolysis-related pseudohyperkalemia becomes clinical relevant. Secondly, temporal dynamics of treatment-induced leukocyte decrease were studied to allow tailored implementation of laboratory information system (LIS) decision rules based on the leukocyte threshold to avoid leukolysis-related pseudohyperkalemia.Materials and methodsPotassium results of AU5811 routine chemistry (Beckman Coulter, Brea, California, USA) and iStat point of care (POC) (Abbott Diagnostics, Chicago, Illinois, USA) analysers were compared, the latter method being insensitive to leukolysis caused by pre-analytical procedures. Potassium results were combined with leukocyte counts obtained using a Cell-Dyn Sapphire haematology analyser (Abbott Diagnostics, Santa Clara, California, USA), resulting in 132 unique data triplets. Regression analysis was performed to establish a leukocyte threshold. The Reference Change Value (√2 x Z x √(CVa2 + CVi2)) was used to calculate maximum allowable difference between routine analyser and POC potassium results (deltamax + 0.58 mmol/L). Temporal analysis on the treatment-induced leukocyte decrease was performed by plotting leukocyte counts in time for all patients above the threshold leukocyte count (N = 41).ResultsEstablished leukocyte threshold was 63 x109/L. Temporal analysis showed leukocyte counts below the threshold within 8 days of treatment for all patients.ConclusionsBased on performed analyses we were able to implement LIS decision rules to reduce pseudohyperkalemia due to preanalytical procedures. This implementation can contribute to a reduction in erroneous (or absence of) treatments in the clinic.  相似文献   

12.
IntroductionHigh prolactin (PRL) concentrations are found in laboratory test results of patients on majority of antipsychotic drugs. Prevalence rates and degrees of severity of hyperprolactinemia (HPRL) based on PRL concentration may depend on the presence of macroprolactin in the serum. The aim of the study was to investigate the difference between PRL concentrations before and after precipitation of macroprolactin and to examine if there were any changes in the categorization of HPRL between samples prior and after precipitation.Materials and methodsTotal of 98 female patients (median age 33; range 19-47 years) diagnosed with a psychotic disorder, proscribed antipsychotic drugs, and with HPRL were included. Total PRL concentration and PRL concentration after macroprolactin precipitation with polyethylene glycol (postPEG-PRL) were determined by the chemiluminometric method on the Beckman Coulter Access2 analyser.ResultsTotal PRL concentrations (median 1471; IQC: 1064-2016 mlU/L) and postPEG-PRL concentrations (median 1453; IQC: 979-1955 mlU/L) were significantly correlated using intraclass correlation coefficient for single measurements (mean estimation 0.96; 95%CI 0.93-0.97) and average measurement (mean estimation 0.98; 95%CI 0.96-0.99), and all investigated female patient had HPRL according to PRL and postPEG-PRL concentration. The median PRL recovery following PEG precipitation was 95; IQC: 90-100%. There was substantial agreement (kappa test = 0.859, 95% CI: 0.764-0.953) between the categories of HPRL severity based on total PRL concentrations and postPEG-PRL concentrations.ConclusionThe study demonstrated that HPRL was present in all subjects using the reference interval for total PRL concentration and postPEG-PRL concentration with no significant impact of macroprolactin presence in the serum on the categorization of patients according to severity of HPRL.  相似文献   

13.
IntroductionIt is often quoted that 70% of clinical decisions are based on laboratory results, but the evidence to substantiate this claim is lacking. Since clinical guidelines aim to document best-practice decision making for specific disease conditions, inclusion of any laboratory test means that the best available evidence is recommending clinicians use it. Cardiovascular disease (CVD) is the world’s most common cause of mortality, so this study reviewed all CVD guidelines published by five national/international authorities to determine what proportion of them recommended laboratory testing.Materials and methodsFive leading CVD guidelines were examined, namely the European Society of Cardiology (ESC), the UK National Institute for Health and Clinical Excellence (NICE), the American College of Cardiology (ACC), the Australian Heart Foundation (AHF) and the Cardiac Society of Australia and New Zealand (CSANZ).ResultsA total of 101 guidelines were reviewed. Of the 33 individual ESC guidelines relating to CVD, 24/33 made a direct reference to the use of clinical laboratory tests in either diagnosis or follow-up treatment. The same applied to 15/20 of NICE guidelines, 24/32 from the ACC and 15/16 from the AHF/CSANZ. Renal function and blood count testing were the most recommended (39 and 26 times), with lipid, troponin and natriuretic peptide measurement advocated 25, 19 and 19 times respectively.ConclusionsThis study has shown that laboratory testing is advocated by between 73% and 94% of individual CVD guideline recommendations from five national/international authorities. This provides an index to assess the potential value of laboratory medicine to healthcare.  相似文献   

14.

Introduction:

Blood collection through intravenous lines frequently causes spurious hemolysis. Due to specific structure, the tube holder Holdex® (Greiner Bio-One GmbH, Kremsmuenster, Austria) is supposed to prevent erythrocyte injury in samples collected from catheters, so that we planned a specific study to support this hypothesis.

Materials and methods:

Blood was collected from emergency department (ED) patients with 20-gauge catheter. In patients with odd order numbers, first and second tubes were collected with conventional holder (BD Vacutainer One Use Holder, Becton Dickinson, Milan, Italy) and the third with Holdex, whereas in even patients first and second tubes were drawn with Holdex and the third using BD Vacutainer One Use Holder. The first tube was discarded, whereas the second and third were centrifuged and serum was tested for potassium, lactate dehydrogenase (LD) and hemolysis index.

Results:

The final study population consisted in 60 ED patients. Concentrations of potassium (4.25 vs. 4.16 mmol/L; P = 0.031), LD (498 vs. 459 U/L; P = 0.039) and cell-free hemoglobin (0.42 vs. 0.22 g/L; P = 0.042) were higher in samples collected with BD Vacutainer One Use Holder than with Holdex. The mean bias of cell-free hemoglobin was −0.4 g/L in samples collected with Holdex. Although the frequency of samples with cell-free hemoglobin > 0.5 g/L was identical (17/60 vs. 17/60; P = 1.00), the frequency of those with concentrations >3.0 g/L was higher using BD Vacutainer One Use Holder than Holdex (4/60 vs. 0/60; P = 0.042).

Conclusions:

The use of Holdex for drawing blood from intravenous lines may be effective for reducing gross hemolysis.  相似文献   

15.
Acute coronary syndrome (ACS) is a term for a range of clinical signs and symptoms suggestive of myocardial ischemia. It results in functional and structural changes and ultimately releasing protein from injured cardiomyocytes. These cardiac markers play a major role in diagnosis and prognosis of ACS. This study aims to assess the efficacy of heart type fatty acid binding protein (h-FABP) as a marker for ACS along with the routinely used hs-TropT. In our observational study, plasma h-FABP (cut-off 6.32 ng/ml) and routinely done hs-Trop T (cutoff 0.1 and 0.014 ng/ml) were estimated by immunometric laboratory assays in 88 patients with acute chest pain. Based on the clinical and laboratory test findings the patients were grouped into ACS (n = 41) and non-ACS (n = 47). The diagnostic sensitivity, specificity, NPV, PPV and ROC curve at 95 % CI were determined. Sensitivity of hs-TropT (0.1 ng/ml), hs-TropT (0.014 ng/ml) and h-FABP were 53, 86 and 78 % respectively and specificity for the same were 98, 73 and 70 % respectively. Sensitivity, specificity and NPV calculated for a cut-off combination of hs-TropT 0.014 ng/ml and h-FABP was 100, 51 and 100 % respectively. These results were substantiated by ROC analysis. Measurement of plasma h-FABP and hs-TropT together on admission appears to be more precise predictor of ACS rather than either hs-Trop T or h-FABP.  相似文献   

16.
BackgroundFermentation process development has been very important for efficient ethanol production. Improvement of ethanol production efficiency from sweet sorghum juice (SSJ) under normal gravity (NG, 160 g/L of sugar), high gravity (HG, 200 and 240 g/L of sugar) and very high gravity (VHG, 280 and 320 g/L of sugar) conditions by nutrient supplementation and alternative feeding regimes (batch and fed-batch systems) was investigated using a highly ethanol-tolerant strain, Saccharomyces cerevisiae NP01.ResultsIn the batch fermentations without yeast extract, HG fermentation at 200 g/L of sugar showed the highest ethanol concentration (PE, 90.0 g/L) and ethanol productivity (QE, 1.25 g/L·h). With yeast extract supplementation (9 g/L), the ethanol production efficiency increased at all sugar concentrations. The highest PE (112.5 g/L) and QE (1.56 g/L·h) were observed with the VHG fermentation at 280 g/L of sugar. In the fed-batch fermentations, two feeding regimes, i.e., stepwise and continuous feedings, were studied at sugar concentrations of 280 g/L. Continuous feeding gave better results with the highest PE and QE of 112.9 g/L and 2.35 g/L·h, respectively, at a feeding time of 9 h and feeding rate of 40 g sugar/h.ConclusionsIn the batch fermentation, nitrogen supplementation resulted in 4 to 32 g/L increases in ethanol production, depending on the initial sugar level in the SSJ. Under the VHG condition, with sufficient nitrogen, the fed-batch fermentation with continuous feeding resulted in a similar PE and increased QP by 51% compared to those in the batch fermentation.  相似文献   

17.

Introduction:

Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer® Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum separation. Our aim was to evaluate the comparability of routine chemistry parameters in BD Vacutainer® RST blood collection tube in reference with the BD Vacutainer® Serum Separating Tubes II Advance Tube (SST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA).

Materials and methods:

Blood specimens were collected from 90 participants for evaluation on its results, clotting time and stability study of six routine biochemistry parameters: glucose (Glu), aspartate aminotransferase (AST), alanine aminotransferase (ALT), calcium (Ca), lactate dehidrogenase (LD) and potassium (K) measured with Olympus AU2700 analyzer (Beckman Coulter, Tokyo, Japan). The significance of the differences between samples was assessed by paired t-test or Wilcoxon Matched-Pairs Rank test after checking for normality.

Results:

Clotting process was significantly shorter in the RSTs compared to SSTs (2.49 min vs. 19.47 min, respectively; P < 0.001). There was a statistically significant difference between the RST and SST II tubes for glucose, calcium and LD (P < 0.001). Differences for glucose and LD were also clinically significant. Analyte stability studies showed that all analytes were stable for 24 h at 4 °C.

Conclusions:

Most results (except LD and glucose) from RST are comparable with those from SST. In addition, RST tube provides shorter clotting time.  相似文献   

18.
IntroductionThe aim of the present study was to determine and compare the concentration of hyaluronic acid (HA) in rheumatoid arthritis (RA), systemic sclerosis (SSc) and systemic lupus erythematosus (SLE), and its correlation with parameters of disease activity and duration. The hypothesis was that HA should be increased in rheumatic diseases. We also expected that HA could be a marker of disease activity and inflammation in some of these diseases.Materials and methodsThe study group comprised 149 patients with RA, SSc and SLE hospitalized in the Department of Rheumatology and Internal Diseases, Medical University of Bialystok (Bialystok, Poland) and 30 healthy controls. The concentrations of HA, C-reactive protein (CRP) and rheumatoid factor (RF) were measured using Architect ci8200; haemoglobin, platelets on Sysmex XS-800i; and erythrocyte sedimentation rate (ESR) on Sediplus S 2000 analysers. Statistical analysis was performed using Statistica 13.3 PL.ResultsHyaluronic acid was increased in RA, SLE and SSc when compared to controls (P < 0.001, P = 0.011, and P = 0.015, respectively). There were no differences in HA between rheumatic diseases (P = 0.840). Hyaluronic acid positively correlated with SLE activity (P = 0.025). In RA, HA positively correlated with ESR (P = 0.028) and CRP (P = 0.009). However, HA was not found to correlate with the duration of rheumatic diseases.ConclusionsHyaluronic acid concentration undergoes changes in rheumatic diseases with no difference between RA, SLE and SSc. In RA, HA concentration can be a marker of inflammation, while in SLE patients an indicator of disease activity.  相似文献   

19.
IntroductionOesophageal varices are routinely diagnosed by esophagogastroduodenoscopy (EGD), and their bleeding has high mortality. We aimed to evaluate diagnostic performance of biochemical tests in comparison to elastography-based approaches, as non-invasive alternatives to EGD, for ruling-out high risk oesophageal varices (HRV).Material and methodsRetrospective analysis of patients (N = 861) who underwent liver stiffness measurement (LSM) by transient elastography (TE) in a single centre over 5-year period, with available results of EGD (within 3 months from LSM). Only patients with suspicion of compensated advanced chronic liver disease (cACLD) defined by LSM ≥ 10 kPa were included comprising the final cohort of 73 subjects. Original and expanded Baveno VI criteria (B6C), controlled attenuation parameter (CAP), platelet count (PLT), aspartate aminotransferase to PLT ratio index (APRI), Fibrosis-4 index (FIB4), model for end stage liver disease (MELD) score were evaluated against the results of EGD that served as the reference method.ResultsAnalysed patients had median age 62 years, 59/73 (0.81) were males, 54/73 (0.74) had alcoholic/non-alcoholic fatty liver disease, and 21/73 (0.29) had HRV. In multivariate logistic regression analysis only LSM and PLT were independently associated with HRV. The best performing tests for ruling-out HRV (% of spared EGD; % of missed HRV) were respectively: LSM < 20 kPa (53.4%; 0%), B6C (38%; 0%), Expanded B6C (47.9%; 4.8%); PLT > 214x109/L (21.9%; 0%); FIB4 ≤ 1.8 (21.4%; 0%), APRI ≤ 0.34 (12.3%; 0%). CAP, MELD = 6 alone or combined with PLT > 150(x109/L) did not show acceptable performance.ConclusionThe best performing biochemical tests for ruling-out HRV in our cohort of patients were PLT and FIB-4, but they were still outperformed by elastography-based approaches.Keyword: portal hypertension, cirrhosis, platelet count, esophageal varices, non-invasive tests  相似文献   

20.
BackgroundCurrently, microbial fermentation method has become the research hotspot for acetoin production. In our previous work, an acetoin-producing strain, Bacillus subtilis SF4-3, was isolated from Japanese traditional fermented food natto. However, its conversion of glucose to acetoin was relatively low. In order to achieve a high-efficient accumulation of acetoin in B. subtilis SF4-3, main medium components and fermentation conditions were evaluated in this work.ResultsThe by-products analysis showed that there existed reversible transformation between acetoin and 2,3-butanediol that was strictly responsible for acetoin production in B. subtilis SF4-3. The carbon sources, nitrogen sources and agitation speed were determined to play crucial role in the acetoin production. The optimal media (glucose·H2O 150 g/L, yeast extract 10 g/L, corn steep dry 5 g/L, urea 2 g/L, K2HPO4 0.5 g/L, MgSO4 0.5 g/L) were obtained. Furthermore, the low agitation speed of 300 r/min was found to be beneficial to the reversible transformation of 2,3-butanediol for acetoin production in B. subtilis SF4-3. Eventually, 48.9 g/L of acetoin and 5.5 g/L of 2,3-butanediol were obtained in a 5-L fermenter, and the specific production of acetoin was 39.12% (g/g), which accounted for 79.90% of the theoretical conversion.ConclusionsThe results indicated acetoin production of B. subtilis SF4-3 was closely related to the medium components and dissolved oxygen concentrations. It also provided a method for acetoin production via the reversible transformation of acetoin and 2,3-butanediol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号