首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.

Introduction:

We hypothesized that patients are poorly informed about proper procedure for 24-hour urine specimen collection and its relevance in determination of biochemical analytes, despite availability of leaflets and webpage with instruction for collection. The aim of this survey was to question outpatients how well are they informed about procedure of 24-hour urine specimen collection.

Materials and methods:

The survey with 10 questions was done in outpatient laboratory of University Department of Chemistry, Medical School University Hospital Sestre Milosrdnice, Zagreb, Croatia. The study included 59 patients with collected 24-hour urine sample who have consented to participate in the survey.

Results:

Out of 59 participants, most of them (0.97) were older than 40 years. Internet was not recognized as a source of information (1/59). Almost one third of the patients have changed their drinking habits to collect more urine volume. Although most of the patients (0.60) were aware that the bottle of water is the best choice for the container, almost half of them were collected urine samples in the plastic soft drink bottle. Laboratory staff and physicians often have given information about proper collection procedure, but that information was insufficient.

Conclusions:

Patients are usually not aware of importance of proper preanalytical procedure for collecting urine specimen and how improper collection could affect results of requested tests. Education of outpatients, general practitioners and laboratory staff is needed in order to improve sample quality and trueness of results.  相似文献   

2.

Introduction:

Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration.

Materials and methods:

Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot.

Results:

Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error.

Conclusion:

Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.  相似文献   

3.

Introduction:

We present our work of monitoring 202 different patients with markedly elevated serum index for lipemia whereby serum samples were clear. We tried to clarify the cause of occurrence of these indices which were detected in the years 2006–2010 on Siemens Dimension analyzers.

Materials and methods:

In samples with unusual lipemia index we measured the concentration of lipids (total cholesterol, triglycerides, HDL and LDL cholesterol, Lp(a), ApoA1, ApoB), total proteins and checked for possible interferents (rheumatoid factor, immunoglobulins). We performed serum protein and immuno- electrophoresis. We investigated the repeatability of unusual lipemia indices during the day and after different time periods and we compared them on four different analyzers (RXL Max, Vista, Hitachi 911 and former Olympus AU640).

Results:

In 87% of 202 samples we found a monoclonal or biclonal peak in serum protein electrophoresis. Different types of paraproteins were confirmed with immunofixation electrophoresis. In the remaining 13%, polyclonal elevated concentrations of immunoglobulins were measured. Other parameters had no influence on appearing of these indices. The repeatability of indices was good during the first day of measurements (P values > 0.05) and markedly lower in the next days or after 3 and 12 months (P values < 0.05). The indices were elevated only on Dimension analyzers, but not on Hitachi and former Olympus analysers.

Conclusion:

A markedly elevated lipemia index in a clear serum sample measured on Siemens analyzers Dimension indicates a high possibility for the presence of a paraprotein in the sample.  相似文献   

4.

Introduction

The study was performed to compare and analyze the inter-departmental variability in the request of rarely requested laboratory tests in primary care, as opposed to other more common and highly requested tests.

Materials and methods

Data from production statistics for the year 2012 from 76 Spanish laboratories was used. The number of antinuclear antibodies, antistreptolysin O, creatinine, cyclic citrullinated peptide antibodies, deaminated peptide gliadine IgA antibodies, glucose, protein electrophoresis, rheumatoid factor, transglutaminase IgA antibodies, urinalysis and uric acid tests requested was collected. The number of test requests per 1000 inhabitants was calculated. In order to explore the variability the coefficient of quartile dispersion was calculated.

Results

The smallest variation was seen for creatinine, glucose, uric acid and urinalysis; the most requested tests. The tests that were least requested showed the greatest variability.

Conclusion

Our study shows through a very simplified approach, in a population close to twenty million inhabitants, how in primary care, the variability in the request of laboratory tests is inversely proportional to the request rate.Key words: primary care, laboratory proficiency testing, clinical laboratory services, test requesting, preanalytical phase  相似文献   

5.

Introduction:

Zonulin is a eukaryotic protein structurally similar to Vibrio cholerae’s zonula occludens toxin. It plays an important role in the opening of small intestine tight junctions. The loss of gut wall integrity during sepsis might be pivotal and has been described in various experimental as well as human studies. Increased levels of zonulin could be demonstrated in diseases associated with increased intestinal inflammation, such as celiac disease and type 1 diabetes. We therefore investigated the role of plasma levels of zonulin in patients with sepsis as a non-invasive marker of gut wall integrity.

Materials and methods:

Plasma level of zonulin was measured in 25 patients with sepsis, severe sepsis or septic shock according to ACCP/SCCM criteria at the first day of diagnosed sepsis. 18 non-septic post-surgical ICU-patients and 20 healthy volunteers served as control. Plasma levels were determined by using commercially available ELISA kit. Data are given as median and interquartile range (IQR).

Results:

Significantly higher plasma concentration of zonulin were found in the sepsis group: 6.61 ng/mL (IQR 3.51–9.46), as compared to the to the post-surgical control group: 3.40 ng/mL (IQR 2.14–5.70) (P = 0.025), as well as to the healthy group: 3.55 ng/mL (IQR 3.14–4.14) (P = 0.008).

Conclusion:

We were able demonstrate elevated levels of plasma zonulin, a potential marker of intestinal permeability in septic patients. Increased zonulin may serve as an additional mechanism for the observed increased intestinal permeability during sepsis and SIRS.  相似文献   

6.

Introduction:

Studies about vitamin D [25(OH)D] stability in plasma are limited and preanalytical variables such as tube type may affect results. We aimed to evaluate effect of storage conditions, sample type and some preanalytical variables on vitamin D concentration.

Materials and methods:

Blood samples from 15 healthy subjects were centrifuged at different temperatures and stored under different conditions. Serum and plasma 25(OH)D difference, effect of centrifugation temperature and common storage conditions were investigated.

Results:

There was no difference between serum and plasma vitamin D concentration. Centrifugation temperature had no impact on vitamin D concentration. 25(OH)D is stable under common storage conditions: 4 hours at room temperature, 24 hours at 2–8 °C, 7 days at −20 °C, 3 months at −80 °C.

Conclusion:

Vitamin D does not require any special storage conditions and refrigeration. Both serum and plasma can be used for measurement.  相似文献   

7.

Introduction:

Two Italian adults arrived at the Emergency Department referring diarrhea, nausea and vomiting for 4 days; weakness, fatigue and visual hallucinations were also complained of. Patients reported the ingestion of some leaves of a plant, which they supposed to be “donkey ears”, a week before. Physical examination showed hypotension and bradycardia and ECG examination disclosed sinus rhythm and repolarization abnormalities (scooping of the ST-T complex) in both patients and a 2:1 AV block in the man.

Materials and methods:

Digoxin concentration was evaluated twice for each patient (at the admission and after 4 hours) by the automated immunoassay system ADVIA Centaur®. Digitoxin concentration was evaluated by liquid chromatography-mass spectrometry (LC-MS/MS).

Results:

Despite clinical picture was suggestive of digitalis intoxication, digoxin levels were undetectable. Due to the more severe clinical picture, the male patient was treated with anti-digoxin antibodies (Digifab®) achieving a good clinical improvement and remission of the AV block within two hours. Initial diagnosis was confirmed by LC-MS/MS showing high digitoxin concentrations, but digoxin was undetectable. Patients remained stable and 48 hours later were discharged from the hospital.

Conclusion:

Whereas digoxin determination frequently relies on monoclonal antibodies which do not cross-react to digitoxin, polyclonal antibodies constituting Digifab® recognize a large spectrum of cardiac glycosides, including digitoxin. This report emphasizes the primary role of the clinical approach to patients in the emergency setting and how an active communication and a continuous sharing of professional experiences between Laboratory and Clinicians ensure an early and correct diagnosis.  相似文献   

8.

Background

In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.

Material and methods

Data were collected from 319 patients admitted to the emergency department of a cardiology hospital from January–July 2014. EDTA blood samples drawn at admission were analyzed using automated hematology system, and BNP concentration was measured using a fluorescence immunoassay.

Results

The study included 190 patients with and 129 without acute heart failure (AHF). These groups had BNP concentration of 200-5000 ng/L and 5-98 ng/L, respectively. MPV levels were significantly higher in the AHF group (P < 0.001). BNP concentrations were positively correlated with MPV (r = 0.41, P < 0.001) and neutrophil / lymphocyte ratio (r = 0.38, P < 0.001).

Conclusion

Increased MPV values correlate with BNP concentration, an indicator of HF severity and clinical status, in patients with AHF admitted to the emergency department.Key words: natriuretic peptide, brain; heart failure; platelet; mean platelet volume  相似文献   

9.

Introduction:

Serum blood collection tubes with separator gel are widely used by many laboratories for chemistry analyses. We describe a case of a primary blood collection tube filled with blood sample and a floating separator gel.

Materials and methods:

The blood sample was collected from a 51 years old female in intensive care unit with the diagnosis of pneumonia into a BD Vacutainer SST tube (Becton Dickinson, NJ, USA) containing serum separator gel and conveyed to the core laboratory of Marmara University Hospital within 30 minutes from collection. Sample was immediately centrifuged at room temperature at 1500 × g for 10 minutes.

Results:

The analyses revealed a highly increased total protein concentration of 145 g/L (reference interval 64–83 g/L). The nephelometric analyses showed an elevated serum IgG concentration of 108 g/L (reference interval 6.5–16 g/L) and IgG lambda monoclonal band was determined by serum immunofixation electrophoresis.

Conclusion:

Limitation of the separator gel tubes in patients with a high plasma density and its possible effects on test results and laboratory costs should be remembered. The clinical diagnosis stated in the information system should also reveal known comorbid conditions besides the apparent admission reason. This information would avoid resampling, additional testing, and communication efforts with the clinicians.  相似文献   

10.

Introduction

Vaspin (visceral adipose tissue-derived serpin) was first described as an insulin-sensitizing adipose tissue hormone. Recently its anti-inflammatory function has been demonstrated. Since no appropriate data is available yet, we sought to investigate the plasma concentrations of vaspin in sepsis.

Materials and methods

57 patients in intensive care, fulfilling the ACCP/SCCM criteria for sepsis, were prospectively included in our exploratory study. The control group consisted of 48 critically ill patients, receiving intensive care after trauma or major surgery. Patients were matched by age, sex, weight and existence of diabetes before statistical analysis. Blood samples were collected on the day of diagnosis. Vaspin plasma concentrations were measured using a commercially available enzyme-linked immunosorbent assay.

Results

Vaspin concentrations were significantly higher in septic patients compared to the control group (0.3 (0.1-0.4) ng/mL vs. 0.1 (0.0-0.3) ng/mL, respectively; P < 0.001). Vaspin concentration showed weak positive correlation with concentration of C-reactive protein (CRP) (r = 0.31, P = 0.002) as well as with SAPS II (r = 0.34, P = 0.002) and maximum of SOFA (r = 0.39, P < 0.001) scoring systems, as tested for the overall study population.

Conclusion

In the sepsis group, vaspin plasma concentration was about three-fold as high as in the median surgical control group. We demonstrated a weak positive correlation between vaspin and CRP concentration, as well as with two scoring systems commonly used in intensive care settings. Although there seems to be some connection between vaspin and inflammation, its role in human sepsis needs to be evaluated further.Key words: adipocytokine, inflammation, vaspin, CRP, intensive care  相似文献   

11.

Introduction

Diagnosis and monitoring of diabetes mellitus in sub-Saharan Africa, based on blood analyses, are hampered by infrastructural and cultural reasons. The first aim of this study was to evaluate the diagnostic accuracy of glycated nail proteins for diabetes mellitus. The second aim was to compare the course of short- and long-term glycemic biomarkers after 6 months of antidiabetic treatment. These objectives should support our hypothesis that glycated nail proteins could be used as an alternative glycemic biomarker.

Materials and methods

This case-control study consisted of 163 black diabetics and 67 non-diabetics of the South Kivu (Democratic Republic of Congo). Diagnostic accuracy of glycated nail proteins was evaluated using ROC curve analysis. At the start of the study, glycated nail protein concentrations were compared between diabetics and non-diabetics, using a nitro blue tetrazolium (NBT) colorimetric method. In a subgroup of 30 diabetics, concentrations of glycated nail proteins, fasting glucose (Accu-Chek® Aviva), serum fructosamine (NBT) and HbA1c (DCA-2000+®) were measured at start and after 6 months.

Results

ROC analysis yielded an AUC of 0.71 (95% confidence interval (CI): 0.65-0.76) and a cut-off point of 3.83 μmol/g nail. Concentration of glycated nail proteins was significantly higher (P < 0.001) in diabetics in comparison with non-diabetics. After 6 months of antidiabetic treatment, a significant drop in the fasting glucose concentration (P = 0.017) and concentration of glycated nail proteins (P = 0.008) was observed in contrast to serum fructosamine and HbA1c.

Conclusions

Measurement of glycated nail proteins could be used to diagnose and monitor diabetes mellitus in sub-Saharan Africa.Key words: fasting glucose concentration, fructosamine, hemoglobin A1c protein, nails, sub-Saharan Africa, diabetes mellitus  相似文献   

12.

Introduction:

In this work we report on the possible effect of the medical therapy on CDT concentration in a chronic alcohol abuser, with known medical history (July 2007 – April 2012) and alcohol abuse confirmed by relatives.

Case history:

At the end of 2007, patient displayed the following laboratory results: AST 137 U/L, ALT 120 U/L, GGT 434 U/L, MCV 101 fL and CDT 3.3%. On December 2007, after double coronary artery bypass surgery, he began a pharmacological treatment with amlodipine, perindopril, atorvastatin, isosorbide mononitrate, carvedilol, ticlopidine and pantoprazole. In the next months, until may 2011, the patient resumed alcohol abuse, as confirmed by relatives; however, CDT values were repeatedly found negative (0.8% and 1.1%) despite elevated transaminases and GGT, concurrent elevated ethyl glucuronide concentration (> 50 mg/L) and blood alcohol concentration (> 1 g/L). Alcohol consumption still continued despite increasing disulfiram doses ordered by an Alcohol Rehab Center. On May 2011, the patient was transferred to a private medical center where he currently lives.

Conclusions:

This study suggests the possibility that a medical therapy including different drugs may hamper the identification of chronic alcohol abusers by CDT.  相似文献   

13.

Introduction

Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L.

Materials and methods

Baseline (group I) serum pool with glucose concentration of 5.55 (5.44-5.61) mmol/L was prepared from patient sera. Spiking with 20% dextrose solution, sample groups were obtained with glucose concentrations: 17.09, 34.52, and 50.95 mmol/L (group II, III, IV, respectively). Total of 21 biochemistry analytes and thyroid tests were studied on Abbott c8000 and i2000sr with commercial reagents. Bias from baseline value was checked statistically and clinically.

Results

Creatinine increased significantly by 8.74%, 31.66%, 55.31% at groups II, III, IV, respectively with P values of < 0.001. At the median glucose concentration of 50.95 mmol/L, calcium, albumin, chloride and FT4 biased significantly clinically (-0.85%, 1.63%, 0.65%, 7.4% with P values 0.138, 0.214, 0.004, < 0.001, respectively). Remaining assays were free of interference.

Conclusion

Among the numerous biochemical parameters studied, only a few parameters are affected by dramatically increased glucose concentration. The creatinine measurements obtained in human sera with the Jaffe alkaline method at high glucose concentrations should be interpreted with caution. Other tests that were affected with extremely high glucose concentrations were calcium, albumin, chloride and FT4, hence results should be taken into consideration in patients with poor diabetic control.Key words: assay interference, glucose interference, preanalytical phase, creatinine, Jaffe kinetic assay, thyroid function tests  相似文献   

14.

Introduction:

Non insulin dependent diabetes mellitus is the most common type of diabetes. Genetic factors, lipid profiles, hypertension are potential risk factors for diabetes mellitus. Adenosine binding cassette transporter proteins 1 (ABCA1) plays a role in cholesterol metabolism, especially high density lipoprotein (HDL-cholesterol). There are multiple mechanisms by which HDL-cholesterol can be atheroprotective, it is clear that the relative activity of ABCA1 plays a major role. We aimed to investigate association of ABCA1 C69T gene polymorphism with lipid levels in Turkish type 2 diabetic patients.

Materials and methods:

After isolation of DNA by ethanol precipitation we determined ABCA1 gene polymorphism by using polimerase chain reaction - restriction fragment lenght polymorphism (PCR-RFLP) method in 107 type 2 diabetic patients and 50 healthy controls.

Results:

We have observed that the frequency of TT genotype is significantly higher in healthy controls compared to patients (14% vs. 3%; P = 0.008). Also frequency of T allele was higher in controls than in patients (34% vs. 21%; P = 0.020; OR (95% CI) = 0.52 (0.30–0.88)). There was no association of lipid levels and ABCA1 C69T polymorphism subgroups.

Conclusion:

We have found significantly higher frequency of both T allele and genotype in control group when compared to patients that made us think that T allele may be a protective factor against diabetes mellitus. But, we could not find a relationship between genotypes and lipid concentrations in our two groups. Larger studies will help us to understand the relationship between ABCA1 C69T genotype and lipid parameters in diabetes mellitus.  相似文献   

15.
16.
17.

Introduction

Recently several diagnostic manufacturers have launched new 25-hydroxy-vitamin D (25[OH]D) assays, which are aligned to the National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM) (NIST, Gaithersburg, Maryland). The aim of this study was to compare the performance of one liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, one enzyme linked immunosorbent assay (ELISA), and one recalibrated and previous version of a chemiluminescence immunoassay (CLIA).

Material and methods

Serum-aliquots of 198 patient samples from routine 25(OH)D analysis were measured by the ClinMass® LC-MS/MS Complete Kit (RECIPE Chemicals + Instruments GmbH, Munich, Germany), the ORGENTEC 25(OH)D3/D2 ELISA (ORGENTEC Diagnostika GmbH, Mainz, Germany), the recalibrated Immunodiagnostic Systems (IDS)-iSYS 25(OH)DS and the previous used IDS-iSYS 25(OH)D CLIA (Immunodiagnostic Systems Ltd, Boldon, United Kingdom). Bland-Altman and Deming regression analyses were calculated for methods comparison of all tested 25(OH)D assays. The LC-MS/MS method was defined as the reference method. Within-run and between-run precision measurements were performed for all methods with three different concentration levels.

Results

Compared to the LC-MS/MS method, the new IDS-iSYS 25(OH)DS and ORGENTEC 25(OH)D3/D2 assay demonstrated mean relative biases of 16.3% and 17.8%. The IDS-iSYS 25(OH)D assay showed the lowest mean bias of 1.5%. Deming regression analyses of the recalibrated IDS-iSYS 25(OH)DS and the ORGENTEC 25(OH)D3/D2 assay showed proportional differences, when compared to the reference method. All assays showed a within-run and between-run imprecision of ≤ 20% at each of the evaluated concentration levels.

Conclusions

The evaluated standardized immunoassays and LC-MS/MS are useful methods for measuring 25(OH)D serum-levels in clinical laboratories.Key words: vitamin D, immunoassays, liquid chromatography-tandem mass spectrometry, reference standards, quality improvement  相似文献   

18.

Introduction:

The aim of this study was to investigate whether serum levels of interleukin-1β (IL–1β) has any possible correlation on inflammatory parameters such as C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and fibrinogen concentration in patients with familial Mediterranean fever (FMF) patients during attack-free period.

Materials and methods:

The serum levels of IL-1β, as an indicator of cytokines status, and the acute phase response proteins, CRP, ESR and fibrinogen levels were evaluated in 35 attack-free patients with FMF and 25 healthy volunteers.

Results:

Serum IL-1β levels were significantly higher in patients with FMF than control subjects (P = 0.018). There was no statistically significant difference in the serum levels of ESR, CRP and fibrinogen between two groups (P = 0.181, P = 0.816, P = 0.686, respectively). There was a significant correlation between IL-1β and CRP (r = 0.513, P = 0.002) values of FMF group.

Conclusions:

In conclusion, our results confirm the presence of increased IL-1β levels in FMF patients during attack-free period. Serum IL-1β values seems to correlate with CRP levels. The elevation of IL-1β levels may be important in monitoring subclinical inflammation of attack free period in FMF patients.  相似文献   

19.

Introduction

The aim of the study was to present a protocol for laboratory information system (LIS) and hospital information system (HIS) validation at the Institute of Clinical Chemistry and Laboratory Medicine of the Merkur University Hospital, Zagreb, Croatia.

Materials and methods:

Validity of data traceability was checked by entering all test requests for virtual patient into HIS/LIS and printing corresponding barcoded labels that provided laboratory analyzers with the information on requested tests. The original printouts of the test results from laboratory analyzer(s) were compared with the data obtained from LIS and entered into the provided template. Transfer of data from LIS to HIS was examined by requesting all tests in HIS and creating real data in a finding generated in LIS. Data obtained from LIS and HIS were entered into a corresponding template. The main outcome measure was the accuracy of transfer obtained from laboratory analyzers and results transferred from LIS and HIS expressed as percentage (%).

Results:

The accuracy of data transfer from laboratory analyzers to LIS was 99.5% and of that from LIS to HIS 100%.

Conclusion:

We presented our established validation protocol for laboratory information system and demonstrated that a system meets its intended purpose.  相似文献   

20.

Introduction:

There are a number of pre-analytical and analytical factors, which cause false results in the complete blood count. The present case identifies cold agglutinins as the cause for the mismatch between hematocrit and hemoglobin values.

Materials and methods:

70-year old female patient had a history of cerebrovascular diseases and rheumatoid arthritis. During routine laboratory examination, the patient had normal leukocyte and platelet counts; however, the hemoglobin (Hb: 105 g/L) and hematocrit (HCT: 0.214 L/L) results were discordant. Hemolysis, lipemia and cold agglutinin were evaluated as possible reasons for the mismatch between hematocrit and hemoglobin values.

Results:

First blood sample was slightly hemolysed. Redrawn sample without hemolysis or lipemia was analyzed but the mismatch became even more distinct (Hb: 104 g/L and HCT: 0.08 L/L). In this sample, the titration of the cold agglutinin was determined and found to be positive at 1:64 dilution ratios. After an incubation of the sample at 37°C for 2 hours, reversibility of agglutination was observed.

Conclusion:

We conclude that cold agglutinins may interfere with the analysis of erythrocyte and erythrocyte-related parameters (HCT, MCV, MCH and MCHC); however, Hb, leukocyte and platelet counts are not affected.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号