首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 14 毫秒
1.
In this work, we design and fabricate a miniaturized spiral-shaped microchannel device which can be used for high-throughput particle/cell ordering, enrichment, and purification. To probe into the flow rate regulation mechanism, an experimental investigation is carried out on the focusing behaviors of particles with significantly different sizes in this device. A complete picture of the focusing position shifting process is unfolded to clarify the confusing results obtained from flow regimes with different dominant forces in past research. Specifically, with the increase of the flow rate, particles are observed to first move towards the inner wall under the dominant inertial migration, then stabilize at a specific position and finally shift away from the inner wall due to the alternation of the dominant force. Novel phenomena of focusing instability, co-focusing, and focusing position interchange of differently sized particles are also observed and investigated. Based on the obtained experimental data, we develop and validate, for the first time, a five-stage model of the particle focusing process with increasing flow rate for interpreting particle behaviors in terms of the competition between inertial lift and Dean drag forces. These new experimental findings and the proposed process model provide an important supplement to the existing mechanism of inertial particle flow and enable more flexible and precise particle manipulation. Additionally, we examine the focusing behaviors of bioparticles with a polydisperse size distribution to validate the explored mechanisms and thus help realize efficient enrichment and purification of these particles.  相似文献   

2.
In this paper, we use a spiral channel inertial focusing device for isolation and purification of chromosomes, which are highly asymmetric. The method developed is proposed as a sample preparation process for transchromosomic research. The proposed microfluidics-based chromosome separation approach enables rapid, label-free isolation of bioactive chromosomes and is compatible with chromosome buffer. As part of this work, particle force analysis during the separation process is performed utilizing mathematic models to estimate the expected behavior of chromosomes in the channel and the model validated with experiments employing fluorescent beads. The chromosome sample is further divided into subtypes utilizing fluorescent activated cell sorting , including small condensed chromosomes, single chromosomes, and groups of two chromosomes (four sister chromatids). The separation of chromosome subtypes is realized based on their shape differences in the spiral channel device under high flow rate conditions. When chromosomes become aligned in the shear flow, the balance between the inertial focusing force and the Dean flow drag force is determined by the chromosome projection area and aspect ratio, or shape difference, leading to different focusing locations in the channel. The achieved results indicate a new separation regime in inertial microfluidics that can be used for the separation of non-spherical particles based on particle aspect ratios, which could potentially be applied in fields such as bacteria subtype separation and chromosome karyotyping.  相似文献   

3.
The explosive development of inertial microfluidic systems for label-free sorting and isolation of cells demands improved understanding of the underlying physics that dictate the intriguing phenomenon of size-dependent migration in microchannels. Despite recent advances in the physics underlying inertial migration, migration dynamics in 3D is not fully understood. These investigations are hampered by the lack of easy access to the channel cross section. In this work, we report on a simple method of direct imaging of the channel cross section that is orthogonal to the flow direction using a common inverted microscope, providing vital information on the 3D cross-sectional migration dynamics. We use this approach to revisit particle migration in both straight and curved microchannels. In the rectangular channel, the high-resolution cross-sectional images unambiguously confirm the two-stage migration model proposed earlier. In the curved channel, we found two vertical equilibrium positions and elucidate the size-dependent vertical and horizontal migration dynamics. Based on these results, we propose a critical ratio of blockage ratio (β) to Dean number (De) where no net lateral migration occurs (β/De ∼ 0.01). This dimensionless number (β/De) predicts the direction of lateral migration (inward or outward) in curved and spiral channels, and thus serves as a guideline in design of such channels for particle and cell separation applications. Ultimately, the new approach to direct imaging of the channel cross section enables a wealth of previously unavailable information on the dynamics of inertial migration, which serves to improve our understanding of the underlying physics.  相似文献   

4.
Dean Kamen was chosen for a Benjamin Franklin Medal for his resourcefulness and imagination in creating inventions that are assisting disabled and handicapped people to improve their quality of life and health.  相似文献   

5.
Field-free particle focusing in microfluidic plugs   总被引:1,自引:0,他引:1  
Kurup GK  Basu AS 《Biomicrofluidics》2012,6(2):22008-2200810
Particle concentration is a key unit operation in biochemical assays. Although there are many techniques for particle concentration in continuous-phase microfluidics, relatively few are available in multiphase (plug-based) microfluidics. Existing approaches generally require external electric or magnetic fields together with charged or magnetized particles. This paper reports a passive technique for particle concentration in water-in-oil plugs which relies on the interaction between particle sedimentation and the recirculating vortices inherent to plug flow in a cylindrical capillary. This interaction can be quantified using the Shields parameter (θ), a dimensionless ratio of a particle’s drag force to its gravitational force, which scales with plug velocity. Three regimes of particle behavior are identified. When θ is less than the movement threshold (region I), particles sediment to the bottom of the plug where the internal vortices subsequently concentrate the particles at the rear of the plug. We demonstrate highly efficient concentration (∼100%) of 38 μm glass beads in 500 μm diameter plugs traveling at velocities up to 5 mm/s. As θ is increased beyond the movement threshold (region II), particles are suspended in well-defined circulation zones which begin at the rear of the plug. The length of the zone scales linearly with plug velocity, and at sufficiently large θ, it spans the length of the plug (region III). A second effect, attributed to the co-rotating vortices at the rear cap, causes particle aggregation in the cap, regardless of flow velocity. Region I is useful for concentrating/collecting particles, while the latter two are useful for mixing the beads with the solution. Therefore, the two key steps of a bead-based assay, concentration and resuspension, can be achieved simply by changing the plug velocity. By exploiting an interaction of sedimentation and recirculation unique to multiphase flow, this simple technique achieves particle concentration without on-chip components, and could therefore be applied to a range of heterogeneous screening assays in discrete nl plugs.  相似文献   

6.
Vertical hydrodynamic focusing in microfluidic devices is investigated through simulation and through direct experimental verification using a confocal microscope and a novel form of stroboscopic imaging. Optimization for microfluidic cytometry of biological cells is examined. By combining multiple crossing junctions, it is possible to confine cells to a single analytic layer of interest. Subtractive flows are investigated as a means to move the analysis layer vertically in the channel and to correct the flatness of this layer. The simulation software (ADINA and Coventor) is shown to accurately capture the complex dependencies of the layer interfaces, which vary strongly with channel geometry and relative flow rates.  相似文献   

7.
A new microfluidic method that allows hydrodynamic focusing in a microchannel with two sheath flows is demonstrated. The microchannel network consists of a T-shaped main channel and two T-shaped branch channels. The flows of the sample stream and the sheath streams in the microchannel are generated by electroosmotic flow-induced pressure gradients. In comparison with other flow focusing methods, this novel method does not expose the sample to electrical field, and does not need any external pumps, tubing, and valves.  相似文献   

8.
刘兴 《科教文汇》2011,(32):23-24
独立学院是我国高等教育重要组成部分,在教务管理中存在诸多问题。教务员作为学校基层教务管理人员,应准确合理地进行角色定位,防止角色模糊和错位,激发工作的积极性,提高工作效率。  相似文献   

9.
A focusing-based microfluidic mixer was studied. The micromixer utilizes the focusing process required for cytometry to reduce the diffusion distance of molecules to be mixed in order to facilitate the passive diffusion-controlled mixing process. It was found that both the high flow rate ratio of the sheath flow to the flows to be mixed and the low flow rate of the mixing fluids resulted in the short mixing length required within the microfluidic channel. It was shown that a complete mixing was achieved within a distance of 4 mm in the micromixer for the focused mixing fluids at a flow rate of 2 μl∕min and a flow rate ratio of the sheath flow to the flows to be mixed at 4:1. The mixer described here is simple and can be easily fabricated and controlled.  相似文献   

10.
For passive sheathless particles focusing in microfluidics, the equilibrium positions of particles are typically controlled by micro channels with a V-shaped obstacle array (VOA). The design of the obstacles is mainly based on the distribution of flow streamlines without considering the existence of particles. We report an experimentally verified particle trajectory simulation using the arbitrary Lagrangian-Eulerian (ALE) fluid-particle interaction method. The particle trajectory which is strongly influenced by the interaction between the particle and channel wall is systematically analyzed. The numerical experiments show that the streamline is a good approximation of particle trajectory only when the particle locates on the center of the channel in depth. As the advantage of fluid-particle interaction method is achieved at a high computational cost and the streamline analysis is complex, a heuristic dimensionless design objective based on the Faxen''s law is proposed to optimize the VOA devices. The optimized performance of particle focusing is verified via the experiments and ALE method.  相似文献   

11.
Recent years have witnessed a strong trend towards analysis of single-cells. To access and handle single-cells, many new tools are needed and have partly been developed. Here, we present an improved version of a single-cell printer which is able to deliver individual single cells and beads encapsulated in free-flying picoliter droplets at a single-bead efficiency of 96% and with a throughput of more than 10 beads per minute. By integration of acoustophoretic focusing, the cells could be focused in x and y direction. This way, the cells were lined-up in front of a 40 μm nozzle, where they were analyzed individually by an optical system prior to printing. In agreement with acoustic simulations, the focusing of 10 μm beads and Raji cells has been achieved with an efficiency of 99% (beads) and 86% (Raji cells) to a 40 μm wide center region in the 1 mm wide microfluidic channel. This enabled improved optical analysis and reduced bead losses. The loss of beads that ended up in the waste (because printing them as single beads arrangements could not be ensured) was reduced from 52% ± 6% to 28% ± 1%. The piezoelectric transducer employed for cell focusing could be positioned on an outer part of the device, which proves the acoustophoretic focusing to be versatile and adaptable.  相似文献   

12.
Focusing suspended particles in a fluid into a single file is often necessary prior to continuous-flow detection, analysis, and separation. Electrokinetic particle focusing has been demonstrated in constricted microchannels by the use of the constriction-induced dielectrophoresis. However, previous studies on this subject have been limited to Newtonian fluids only. We report in this paper an experimental investigation of the viscoelastic effects on electrokinetic particle focusing in non-Newtonian polyethylene oxide solutions through a constricted microchannel. The width of the focused particle stream is found NOT to decrease with the increase in DC electric field, which is different from that in Newtonian fluids. Moreover, particle aggregations are observed at relatively high electric fields to first form inside the constriction. They can then either move forward and exit the constriction in an explosive mode or roll back to the constriction entrance for further accumulations. These unexpected phenomena are distinct from the findings in our earlier paper [Lu et al., Biomicrofluidics 8, 021802 (2014)], where particles are observed to oscillate inside the constriction and not to pass through until a chain of sufficient length is formed. They are speculated to be a consequence of the fluid viscoelasticity effects.  相似文献   

13.
We have developed a coaxial flow focusing geometry that can be fabricated using soft lithography in poly(dimethylsiloxane) (PDMS). Like coaxial flow focusing in glass capillary microfluidics, our geometry can form double emulsions in channels with uniform wettability and of a size much smaller than the channel dimensions. However, In contrast to glass capillary coaxial flow focusing, our geometry can be fabricated using lithographic techniques, allowing it to be integrated as the drop making unit in parallel drop maker arrays. Our geometry enables scalable formation of emulsions down 7 μm in diameter, in large channels that are robust against fouling and clogging.  相似文献   

14.
Focusing cells into a single stream is usually a necessary step prior to counting and separating them in microfluidic devices such as flow cytometers and cell sorters. This work presents a sheathless electrokinetic focusing of yeast cells in a planar serpentine microchannel using dc-biased ac electric fields. The concurrent pumping and focusing of yeast cells arise from the dc electrokinetic transport and the turn-induced ac∕dc dielectrophoretic motion, respectively. The effects of electric field (including ac to dc field ratio and ac field frequency) and concentration (including buffer concentration and cell concentration) on the cell focusing performance were studied experimentally and numerically. A continuous electrokinetic filtration of E. coli cells from yeast cells was also demonstrated via their differential electrokinetic focusing in a serpentine microchannel.  相似文献   

15.
This paper targets the development of an inertial navigation error-budget system for performance validation before actual field operation. The paper starts by studying the various errors that an inertial measurement unit (IMU) incorporates. A systematic approach of error modeling is proposed. The error models are integrated in time and added to the true measurement of the IMU to obtain the observed measurements. Simulation results are presented to show the contribution of the errors to the final measurement of the IMU. The IMU error model is blended with a GPS measurements’ model and the performance of a GPS/IMU extended Kalman filter (EKF) to IMU errors is shown. The simulated IMU errors are essential to study IMU quality effect on an inertial navigation system's (INS) state estimate accuracy.  相似文献   

16.
17.
研究型大学教师薪酬满意度调研   总被引:18,自引:2,他引:18  
为提升科研整体水平,一批研究型大学正积极进行薪酬制度再设计,以提升教师薪酬满意度,吸引和稳定有竞争力的师资队伍。本文以重庆地区某研究型大学为个案,探询研究型大学教师薪酬满意度现状及影响因素,从中揭示出当前我国研究型大学教师薪酬管理的特点和存在的问题,为我国研究型大学薪酬制度改革提供了建设性启发。  相似文献   

18.
文章应用UG曲面建模方法,阐述如何创建高质量面,拆面原理,通过曲面网格创建四边面。  相似文献   

19.
在实际的SAR场景中,由于载机平台运动的不规律会引入相位误差,这将导致SAR图像出现模糊,甚至不能形成图像,因此需要准确地估计和补偿相位误差.提出一种较好的SAR相位历史估计算法,在方位向应用延时自相关方法进行准确的相位估计,由此实现SAR的准确聚焦成像.该相位估计方法具有较高的计算效率,非常适合于实时SAR系统.利用对实际SAR数据的聚焦处理证明了该方法的有效性.  相似文献   

20.
Some new techniques for initial alignment of strapdown inertial navigation system are proposed in this paper. A new solution for the precise azimuth alignment is given in detail. A new prefilter, which consists of an IIR filter and a Kalman filter using hidden Markov model, is designed to attenuate the influence of sensor noise and outer disturbance. Navigation algorithm in alignment is modified to feedback continuously for the closed-loop system. It is shown that the initial estimated variance setting of azimuth angle error can influence the speed of initial alignment significantly. At the beginning of alignment, Kalman filter must make a very conservative guess at the initial value of azimuth angle error to get a high convergent speed of the azimuth angle. It is pointed out that the low signal to noise ratio makes the ordinary setting of the estimated azimuth variance slow down the convergent speed of the azimuth angle. Also is shown that the large azimuth angle error problem can be solved well by our solution. The feasibility of these new techniques is verified by simulation and experiment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号