首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract

The purpose of this study was to assess both short-term reliability and long-term stability of anthropometric and physical performance measures in highly-trained young soccer players in relation to age and maturation. Data were collected on 80 players from an academy (U13–U18, pre- (n = 14), circum- (n = 32) and post- (n = 34) estimated peak height velocity, PHV). For the reliability analysis, anthropometric and performance tests were repeated twice within a month. For the stability analysis, these tests were repeated 12 times over a 4-year period in 10 players. Absolute reliability was assessed with the typical error of measurement, expressed as a coefficient of variation (CV). Relative reliability and long-term stability were assessed using the intraclass correlation coefficient (ICC). There was no clear age or maturation effect on either the CVs or ICCs: e.g., Post-PHV vs. Pre-PHV: effect size = –0.37 (90% confidence limits (CL):-1.6;0.9), with chances of greater/similar/lower values of 20/20/60%. For the long-term stability analysis, ICCs varied from 0.66 (0.50;0.80) to 0.96 (0.93;0.98) for 10-m sprint time and body mass, respectively. The short-term reliability of anthropometry and physical performance measures is unlikely to be affected by age or maturation. However, some of these measures are unstable throughout adolescence, which questions their usefulness in a talent identification perspective.  相似文献   

2.
Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73–0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.  相似文献   

3.
Abstract

Thirty-eight competitive cross-country skiers were divided into three groups to assess the reliability and validity of a new double poling ergometer. Group A (n = 22) performed two maximal 60-s tests, Group B (n = 8) repeated peak oxygen uptake tests on the double poling ergometer, and Group C (n = 8) performed a maximal 6-min test on the double poling ergometer and a double poling time-trial on snow. The correlation between the power calculated at the flywheel and the power applied at the base of the poles was r = 0.99 (P < 0.05). The power at the poles was 50 – 70% higher than that at the flywheel. There was a high test – retest reliability in the two 60-s power output tests (coefficient of variation = 3.0%) and no significant difference in peak oxygen uptake in the two 6-min all-out tests (coefficient of variation = 2.4%). There was a strong correlation between the absolute (W) and relative power (W · kg?1) output in the 6-min double poling ergometer test and the double poling performance on snow (r = 0.86 and 0.89 respectively; both P < 0.05). In conclusion, our results show that the double poling ergometer has both high reliability and validity. However, the power calculated at the flywheel underestimated the total power produced and needs to be corrected for in ergonomic estimations.  相似文献   

4.
Purpose

Dog owners represent 40% of the population, a promising audience to increase population levels of physical activity. The purpose of this study was to develop and test the psychometric properties of a new instrument to assess social-cognitive theory constructs related to dog walking.

Method

Dog owners (N = 431) completed the Dogs and WalkinG Survey (DAWGS). Survey items assessed dog-walking behaviors and self-efficacy, social support, outcome expectations, and outcome expectancies for dog walking. Test–retest reliability was assessed among 252 (58%) survey respondents who completed the survey twice. Factorial validity and factorial invariance by age and walking level were tested using confirmatory factor analysis.

Results

DAWGS items demonstrated moderate test–retest reliability (ρ = .39–.79; k = .41–.89). Acceptable model fit was found for all subscales. All subscales were invariant by age and walking level, except self-efficacy, which showed mixed evidence of invariance.

Conclusions

The DAWGS is a psychometrically sound instrument for examining individual and interpersonal correlates of dog walking.  相似文献   

5.
ABSTRACT

The purpose of the study was to assess the validity and inter-bike reliability of 10 Wattbike cycle ergometers, and to assess the test–retest reliability of one Wattbike. Power outputs from 100 to 1000 W were applied using a motorised calibration rig (LODE) at cadences of 70, 90, 110 and 130 rev · min?1, which created nineteen different intensities for comparison. Significant relationships (P < 0.01, r2 = 0.99) were found between each of the Wattbikes and the LODE. Each Wattbike was found to be valid and reliable and had good inter-bike agreement. Within-bike mean differences ranged from 0.0 W to 8.1 W at 300 W and 3.3 W to 19.3 W at 600 W. When taking into account the manufacturers stated measurement error for the LODE (2%), the mean differences were less than 2%. Comparisons between Wattbikes at each of the nineteen intensities gave differences from 0.6 to 25.5 W at intensities of 152 W and 983 W, respectively. There was no significant difference (P > 0.05) between the measures of power recorded in the test–retest condition. The data suggest that the Wattbike is an accurate and reliable tool for training and performance assessments, with data between Wattbikes being able to be used interchangeably.  相似文献   

6.
ABSTRACT

Anaerobic performance in youth has received little attention partly due to the lack of a “gold-standard” measurement. However, force-velocity-power (F-v-P) profiling recently showed high reliability and validity in trained adults. Therefore, the aim was to determine the reliability of F-v-P profiling in children and adolescents. Seventy-five children (60 boys, 15 girls; age: 14.1 ± 2.6 years) completed three 30 m sprints. Velocity was measured at 46.875 Hz using a radar device. The F-v-P profile was fitted to a velocity-time curve allowing instantaneous power variables to be calculated. Reliability was assessed using the intra-class correlation coefficient (ICC), coefficient of variation (CV), standard error of measurement (SEM) and smallest worthwhile change (SWC). High reliability was evident for absolute peak (Ppeak) and mean power (Pmean), Ppeak and Pmean expressed relative to body mass, peak and mean velocity, 30 m sprint time, peak horizontal force (F0), relative F0, mechanical efficiency index and fatigue rate (ICC: 0.75–0.88; CV: 1.9–9.4%) with time to peak power demonstrating moderate reliability (ICC: 0.50; CV: 9.5%). The F-v-P model demonstrated at least moderate reliability for all variables. This therefore provides a potential alternative for paediatric researchers assessing sprint performance and the underlying kinetics.  相似文献   

7.
Prospective application of serum cytokines, lipopolysaccharide (LPS), and heat shock proteins (eHSPs) requires reliable measurement of these biomarkers that can signify exercise-induced heat stress in hot conditions. To accomplish this, both short-term (7 day) reliability (at rest, n = 12) and the acute responsiveness of each biomarker to exercise in the heat (pre and post 60-min cycling, 34.5°C and 70% RH, n = 20) were evaluated. Serum was analysed for the concentration of C-reactive protein (CRP), interleukin-6 (IL-6), heat shock protein 72 (eHSP72), immunoglobulin M (IgM) and LPS. Test–retest reliability was determined as the coefficient of variation (CV). Biomarkers with the least short-term within-participant variation were IL-6 (19%, ±20%; CV, ±95% confidence limits (CL)) and LPS (23%, ±13%). Greater variability was observed for IgM, eHSP72 and CRP (CV range 28–38%). IL-6 exhibited the largest increase in response to acute exercise (95%, ±11%, P = < 0.001) and although CRP had a modest CV (12%, ±7%), it increased substantially post-exercise (P = 0.02, ES; 0.78). In contrast, eHSP72 and LPS exhibited trivial changes post-exercise. It appears variation of common inflammatory markers after exercise in the heat is not always discernible from short-term (weekly) variation.  相似文献   

8.
The study compared the agreement, internal consistency, and measurement stability of the GE iDXA, BOD POD, and InBody 720. Body composition of 43 men and 37 women (31.4 ± 10.7 years; 90% Caucasian and 10% other) was assessed in triplicate using each method over two different days. Mean percent body fat (% BF) of the participants was different for all three machines (27.6 ± 10.0% [GE iDXA)] 25.6 ± 10.4% [BOD POD], and 21.3 ± 10.6% [InBody 720]; p < .05). The coefficient of variation for same day repeated measures was 1.06% (GE iDXA), 3.29% (BOD POD), and 2.97% (InBody 720). The coefficient of variation for 2-day repeated measures was 1.81% (GE iDXA), 4.61% (BOD POD), and 4.24% (InBody 720). The difference between the GE iDXA and BOD POD was within acceptable variability, while the InBody 720 significantly underestimated % BF. The internal consistency was highest for the GE iDXA, followed by the InBody 720, and then the BOD POD.  相似文献   

9.
ABSTRACT

Little is known regarding the influence of asthma and exercise, and their interaction, on heart rate variability (HRV) in adolescents.

Thirty-one adolescents with asthma (13.7±0.9 years; 21.9±3.9 kg·m?2; 19 boys, 12 girls) and thirty-three healthy adolescents (13.8±0.9 years; 20.3±3.2 kg·m?2; 16 boys, 17 girls) completed an incremental ramp test and three heavy-intensity constant-work-rate cycle tests. Thirteen adolescents (7 boys, 6 girls; 6 asthma, 7 control) completed six-months high-intensity interval training (HIIT) and were compared to age- and sex-matched controls. Standard time-domain, frequency-domain and non-linear indices of HRV were derived at baseline, three- and six-months.

Asthma did not influence HRV at baseline or following HIIT. Total power, low frequency and normalised low frequency power, and sympathovagal balance increased at three-months in HIIT, subsequently declining towards baseline at six-months. Normalised high frequency power was reduced at three-months in both groups, which was sustained at six-months. No effects of HIIT were observed in the time-domain nor in the non-linear indices.

HRV was not influenced by asthma, potentially because such derangements are a function of disease progression, severity or duration. HIIT may be associated with a short-term shift towards greater sympathetic predominance during exercise, perhaps caused by physiological overload and fatigue.  相似文献   

10.
Inter-day training reliability and variability in artistic gymnastics vaulting was determined using a customised infra-red timing gate and contact mat timing system. Thirteen Australian high performance gymnasts (eight males and five females) aged 11–23 years were assessed during two consecutive days of normal training. Each gymnast completed a number of vault repetitions per daily session. Inter-day variability of vault run-up velocities (at ‐18 to ‐12 m, ‐12 to ‐6 m, ‐6 to ‐2 m, and ‐2 to 0 m from the nearest edge of the beat board), and board contact, pre-flight, and table contact times were determined using mixed modelling statistics to account for random (within-subject variability) and fixed effects (gender, number of subjects, number of trials). The difference in the mean (Mdiff) and Cohen's effect sizes for reliability assessment and intra-class correlation coefficients, and the coefficient of variation percentage (CV%) were calculated for variability assessment. Approach velocity (‐18 to ‐2 m, CV = 2.4–7.8%) and board contact time (CV = 3.5%) were less variable measures when accounting for day-to-day performance differences, than pre-flight time (CV = 17.7%) and table contact time (CV = 20.5%). While pre-flight and table contact times are relevant training measures, approach velocity and board contact time are more reliable when quantifying vaulting performance.  相似文献   

11.
Abstract

In this study, we examined the reliability and construct validity of new soccer skills tests. Twenty soccer players (10 professional and 10 recreational) repeated trials of passing, shooting, and dribbling skills on different days. Passing and shooting skills required players to kick a moving ball, delivered at constant speed, towards one of four randomly determined targets. Dribbling required players to negotiate seven cones over 20 m. Each trial consisted of 28 passes, 8 shots, and 10 dribbles. Ball speed, precision, and success were determined for all tests using video analysis. Systematic bias was small (<9% in all measures) and all outcome measures were similar between trials. Test–retest reliability statistics were as follows: ball speed (passing, shooting, dribbling; coefficient of variation [CV]: 6.5%, 6.9%, 2.4%; ratio limits of agreement [RLOA]: 0.958 ×/÷ 1.091, 0.990 ×/÷ 1.107, 0.993 ×/÷ 1.039), precision (passing, shooting, dribbling; CV: 10.0%, 23.5%, 4.6%; RLOA: 0.956 ×/÷ 1.147, 1.030 ×/÷ 1.356, 1.000 ×/÷ 1.068), and success (passing, shooting, dribbling; CV: 11.7%, 14.4%, 2.2%; RLOA: 1.017 ×/÷ 1.191, 0.913 ×/÷ 1.265, 0.996 ×/÷ 1.035). Professional players performed better than recreational players in at least one outcome measure for all skills. These findings demonstrate the reliability and validity of new soccer skill protocols.  相似文献   

12.
Abstract

The aim of this study was to determine the relative and absolute reliability of second lactate turnpoint using fixed and individual blood lactate method in competitive cyclists. Twenty-eight male, well-trained cyclists (30.2 ± 10.1 years, 72.0 ± 7.4 kg, 177.3 ± 4.7 cm) were recruited to participate in this study. Cyclists completed two incremental cycling tests to exhaustion over a period of 7 days to determine their peak power output, maximal oxygen uptake, maximal heart rate, maximal blood lactate concentration and two lactate turnpoint criteria. The fixed blood concentration criterion (3.5 mM) and an individual criterion were assessed by a lactate-power curve, considering power output, heart rate and oxygen uptake. The main finding of this study was that both lactate turnpoint criteria showed identical low within-subject variation for power output (2.8% coefficient of variation). High values for test–retest correlations ranging from r = 0.70 to r = 0.94 were found for all variables in both threshold criteria. In conclusion, the individual and fixed method to determine the second lactate turnpoint showed similar high absolute and relative reliability in competitive cyclists.  相似文献   

13.
This study examined the psychometric properties of a questionnaire developed with the guidance of the socialization model of child behaviour to understand modifiable correlates of toddlers’ physical activity and sedentary behaviour. Findings are based on 118 parents (33.7 ± 4.9 years; 86% female) of toddlers (19.3 ± 2.7 months; 48% female) from Edmonton, Canada in The Parents’ Role in Establishing healthy Physical activity and Sedentary behaviour habits study (PREPS). The PREPS questionnaire encompassed 21 variables across the constructs of the socialization model of child behaviour. Of the nine variables assessed for internal consistency reliability, eight had good (α ≥ 0.70) reliability. Of the 15 continuous variables assessed for 1-week test–retest reliability, 10 had moderate (intra-class correlation = 0.50–0.74) and 5 had good (intra-class correlation ≥ 0.75) reliability. Of the six categorical variables assessed for 1-week test–retest reliability, two had fair (К = 0.21–0.40), one had moderate (К = 0.41–0.60), one had substantial (К = 0.61–0.80), and two had almost perfect (К = 0.81–1.00) reliability. Of the 12 sedentary behaviour variables assessed for convergent validity, 7 were significantly correlated with children’s screen time, of which three were small (r ≤ 0.29), two were medium (r = 0.30–0.49), and two were large (r ≥ 0.50) effect sizes.  相似文献   

14.
Abstract

The aims of this study were to determine the reliability of an intermittent-sprint cycling protocol and to determine the efficacy of one practice session on main trials. Eleven men, moderately trained team-sport athletes, completed three visits to the laboratory involving a graded-exercise test and practice session and two trials of a Cycling Intermittent-Sprint Protocol separated by three days. Data for practice and main trials were analysed using typical error of measurement, intra-class correlation and least-products regression to determine reliability. Typical error of measurement (expressed as a coefficient of variation) and intra-class correlation for peak power output from all 20 sprints for trial 1 and trial 2 were 2.9 ± 12.8% (95% confidence interval: 2.0–5.0%) and 0.96 (95% confidence interval: 0.85–0.99), respectively. Typical errors of measurement and intra-class correlation for mean power output for all 20 sprints for trials 1 and 2 were 4.2 ± 11.9% (95% confidence interval: 2.9–7.4%) and 0.90 (95% confidence interval: 0.66–0.97), respectively. The results suggest that peak power output provides a more reliable measure than mean power output. The Cycling Intermittent-Sprint Protocol provides reliable measures of intermittent-sprint performance.  相似文献   

15.
PurposeThis review aimed to synthesize previous findings on the test–retest reliability of the 30–15 Intermittent Fitness Test (IFT).MethodsThe literature searches were performed in 8 databases. Studies that examined the test–retest reliability of the 30–15 IFT and presented the intraclass correlation coefficient (ICC) and/or the coefficient of variation (CV) for maximal velocity and/or peak heart rate were included. The consensus-based standards for the selection of health measurement instruments (COSMIN) checklist was used for the assessment of the methodological quality of the included studies.ResultsSeven studies, with a total of 10 study groups, explored reliability of maximal velocity assessed by the 30–15 IFT. ICCs ranged from 0.80 to 0.99, where 70% of ICCs were ≥0.90. CVs for maximal velocity ranged from 1.5% to 6.0%. Six studies, with a total of 7 study groups, explored reliability of peak heart rate as assessed by the 30–15 IFT. ICCs ranged from 0.90 to 0.97 (i.e., all ICCs were ≥0.90). CVs ranged from 0.6% to 4.8%. All included studies were of excellent methodological quality.ConclusionFrom the results of this systematic review, it can be concluded that the 30–15 IFT has excellent test–retest reliability for both maximal velocity and peak heart rate. The test may, therefore, be used as a reliable measure of fitness in research and sports practice.  相似文献   

16.
17.
In The Netherlands, the 4-Skills Scan is an instrument for physical education teachers to assess gross motor skills of elementary school children. Little is known about its reliability. Therefore, in this study the test–retest and inter-rater reliability was determined. Respectively, 624 and 557 Dutch 6- to 12-year-old children were analyzed for test re-test and inter-rater reliability. All tests took place within the school setting. The outcome measure was age-expected motor performance (in years). Results showed a small practice effect of .24 years for re-test sessions and assessment of motor skills was possible with acceptable precision (standard error of measurement = .67 years). Overall, intraclass correlation coefficient (ICC) was .93 (95% confidence interval: .92–.95) for test–retest reliability and .97 for inter-rater reliability. For the repeated measures, the smallest detectable change (SDC) was 1.84 and limits of agreement were –1.60 and 2.08 years. It can be concluded that the 4-Skills Scan is a reliable instrument to assess gross motor skills in elementary school children.  相似文献   

18.
Evaluations were made of the stability reliability of force measurements obtained from an Ariel dynamometer, the test -- retest reliability of force and power data for bench presses using the same dynamometer at multiple velocities, and the logical (face) validity of force and power output using the same instrument and exercise. Stability reliability of the dynamometer was determined from daily duplicate force calibration checks using two standard loads. Intra- and intertest coefficients of variation ranged from 0.07% to 1.16%. The test -- retest reliability of the bench press force and power outputs of 33 young men as well as the logical validity of their bench press force and power outputs were assessed at 0.0, 0.124, 0.496, and 0.868 m · sec-1, respectively. Intraclass correlation coefficients for force and power ranged from .95 to .99. Plots for both force and power were similar to those expected for analogous single-joint exercises. Therefore, data presented here support the stability reliability of the dynamometer for force measurements, the reliability of the bench press protocol, and the face validity of force outputs over a velocity spectrum.  相似文献   

19.

Purpose: To describe the development and preliminary evaluation of the Multicontext Sitting Time Questionnaire (MSTQ). Method: During development of the MSTQ, contexts and domains of sitting behavior were utilized as recall cues to improve the accuracy of sitting assessment. The terms “workday” and “nonworkday” were used to disambiguate occupational and discretionary sitting. An expert panel evaluated content validity. Among 25 participants, test–retest reliability of the MSTQ items was assessed with intraclass correlation coefficients (ICCs). Convergent validity was assessed versus relative and absolute accelerometer-estimated sedentary time and activity log using Pearson (r) or Spearman (ρ) correlation coefficients where appropriate. Results: Pilot testing revealed Web-based MSTQ administration was rapid, scalable, and inexpensive. Most items in the MSTQ demonstrated acceptable reliability (ICCs>.70). Compared with accelerometer-estimated sedentary time relative to total wear time, the MSTQ exhibited a low correlation on workdays (r = .34) and a moderately high correlation on nonworkdays (r = .61). Conclusions: The systematic development of the MSTQ resulted in several improvements over previous tools and may serve as a model for purpose-driven questionnaire design. Additional validation is needed to conclusively determine the utility of the MSTQ.  相似文献   

20.
ABSTRACT

Purpose: This study examined the test-retest reliability and feasibility of select fitness assessments in 7–12 year old children on the autism spectrum. Method: Participants (N = 14; n = 1 female; Mage = 9.5 ± 1.7 years) completed 7 fitness assessments, administered in a random order, on two occasions: Bruce protocol; Modified 6-minute walk test (M6MWT); Wingate anaerobic cycling test; muscle power sprint test (MPST); sit & reach; standing long jump; and grip strength. Intraclass correlations (two-way mixed with absolute agreement) were computed to examine test-retest reliability. Feasibility was assessed by questionnaire following the first administration of each test. Results: The Wingate (ICC = .956), standing long jump (ICC = .925), grip strength (ICC = .913), and sit and reach (ICC = .829) tests demonstrated good- to- excellent reliability, while the Bruce protocol (ICC = .811), M6MWT (ICC = .510), and MPST (ICC = .703) demonstrated moderate- to- good reliability based on the 95% confidence intervals of the ICC. All tests demonstrated assessor-rated feasibility scores of 70/100 or higher and child-rated feasibility scores of 66/100 or higher. Conclusion: The results demonstrate moderate- to excellent test-retest reliability for select fitness tests. Short, single-instruction (e.g., standing long jump) tests may be more reliable than lengthier assessments (e.g., M6MWT) in this population. Implications of this work include the ability of practitioners and researchers to feasibly and reliably measure the fitness of school-aged children on the autism spectrum for ongoing health and behavioural monitoring and intervention purposes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号