首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   115篇
  免费   1篇
教育   29篇
科学研究   50篇
体育   24篇
文化理论   10篇
信息传播   3篇
  2022年   2篇
  2021年   5篇
  2020年   4篇
  2019年   4篇
  2018年   6篇
  2017年   3篇
  2016年   4篇
  2015年   9篇
  2014年   8篇
  2013年   27篇
  2012年   12篇
  2011年   8篇
  2010年   5篇
  2009年   3篇
  2008年   6篇
  2007年   1篇
  2006年   2篇
  2004年   1篇
  2003年   1篇
  2002年   2篇
  1999年   2篇
  1995年   1篇
排序方式: 共有116条查询结果,搜索用时 0 毫秒
111.
The concentration of several biochemical and hematological biomarkers is strongly influenced by a number of preanalytical variables. Several lines of evidence attest that short, middle, and long-term exercise, as well as the relative intensity of physical effort (from mild to strenuous), may influence a broad array of laboratory variables. The amount of extracellular release and clearance from blood of most of these biomarkers is markedly influenced by the biological characteristics of the molecule(s), level of training, type, intensity and duration of exercise, and time of recovery after training. It is hence noteworthy that test results that fall outside the conventional reference ranges in athletes not only may reflect the presence of a given disease, but may frequently mirror an adaptation to regular training or changes that have occurred during and/or following strenuous exercise, and which should be clearly acknowledged to prevent misinterpretation of laboratory data. The aim of this narrative review is to provide an update about the most significant changes of some biochemical and hematological biomarkers in response to physical exercise, for appropriate interpretation of these changes in the context of physically active subjects.  相似文献   
112.

Background:

In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the “vacuum” or “aspiration” mode.

Materials and methods:

The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC.

Results:

In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error.

Conclusions:

Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.  相似文献   
113.
Abstract

Despite its widespread use in performance assessment, the reliability of vertical jump in an ageing population has not been addressed properly. The aim of the present study was to assess intra- and inter-day reliability of countermovement jump in healthy middle-aged (55–65 years) and older (66–75 years) men and women. Eighty-two participants were recruited and asked to perform countermovement jumps on two different occasions interspersed by 4 weeks. The middle-aged groups exhibited excellent absolute reliability for flight height, jump height, peak force, peak power, peak force/body mass, and peak power/body mass, with coefficients of variation ranging from 2.9% to 7.2% in men and from 3.6% to 6.9% in women and moderate-to-high intraclass correlations (0.75 to 0.97 in men; 0.77 to 0.95 in women). The older groups displayed good coefficients of variation (4.2% to 10.8% in men and 3.4% to 9.5% in women), but the intraclass correlations were low-to-high (0.43 to 0.84 in men; 0.42 to 0.93 in women). Overall, intra-session reliability was higher than inter-session reliability. Peak power was by far the most consistent variable, whereas flight and jump height had the most marked variability. The minimum detectable change varied from 10.5% to 33%, depending on the variable examined, suggesting important implications for intervention studies.  相似文献   
114.
There is currently a growing interest in control of stretching of DNA inside nanoconfined regions due to the possibility to analyze and manipulate single biomolecules for applications such as DNA mapping and barcoding, which are based on stretching the DNA in a linear fashion. In the present work, we couple Finite Element Methods and Monte Carlo simulations in order to study the conformation of DNA molecules confined in nanofluidic channels with neutral and charged walls. We find that the electrostatic forces become more and more important when lowering the ionic strength of the solution. The influence of the nanochannel cross section geometry is also studied by evaluating the DNA elongation in square, rectangular, and triangular channels. We demonstrate that coupling electrostatically interacting walls with a triangular geometry is an efficient way to stretch DNA molecules at the scale of hundreds of nanometers. The paper reports experimental observations of λ-DNA molecules in poly(dimethylsiloxane) nanochannels filled with solutions of different ionic strength. The results are in good agreement with the theoretical predictions, confirming the crucial role of the electrostatic repulsion of the constraining walls on the molecule stretching.  相似文献   
115.
IntroductionThe measurement of serum free light chain (FLC) represents a fundamental aspect on the assessment of patients with monoclonal gammopathies (MG). Different analytical methods for FLC have become available with the possibility to obtain different value with a substantial impact on the assessment of patients with MG. This study aimed to evaluate FLC results obtained with two different assays and how the difference value obtained can impact in the patient’s assessment.Materials and methodsNinety-three patient serum samples that underwent analysis for FLC with two different methods, Serum Freelite (The Binding Site, Birmingham, UK) and N-Latex FLC (Siemens, Marburg, Germany), were included in this retrospective study. Statistical analysis was performed to evaluate correlation, difference, and the grade of concordance between the results obtained with the two methods.ResultsSignificant statistical differences between the results obtained from the two methods were found (P < 0.05). A good correlation was found (0.99 for κ FLC, 0.95 for λ FLC, and 0.94 for the κ/λ ratio, respectively). We found a weighted kappa value of 0.65 for κ/λ ratio, 0.65 for λ FLC and 0.90 for κ FLC. A positive bias found with the Bland-Altman plot mirrors overestimation of κ FLC and κ/λ ratio with Freelite compared to N-Latex, whilst a negative bias underscores underestimation of λ FLC by Freelite compared to N-Latex.ConclusionAlthough in general the concordance between Freelite and N-Latex appears satisfactory, several discrepancies could be evidenced and consequently the two assays are not interchangeable.  相似文献   
116.
Despite official government srt (in various jurisdictions around the world) for providing students with opportunities to construct their own knowledge within the context of formal schooling, school science systems continue to place greatest priority on teaching and learning of products of science (e.g., laws and theories), while compromising students’ opportunities to develop realistic conceptions about science and expertise for doing science. Based on qualitative data analyzed using constant comparative methods (based on constructivist grounded theory), we found this also to be the case – paradoxically – in a school belonging to the Canadian Coalition for Self-directed Learning (CCSDL). Schools in this coalition espouse, among various goals, enabling students to construct their own knowledge, in ways and directions suiting their individual needs, interests, perspectives, and abilities, in addition to gaining access to knowledge developed by society. The science department within the coalition school in this study experienced considerable difficulty realizing this goal, despite school-level administrative support for a concerted effort to reinvent itself along these lines. Factors that appeared to influence the science department’s efforts included those in each of Schwab’s (1969) educational "commonplaces;” that is, the curriculum, teachers, students, and the milieu surrounding teaching and learning. Further analysis suggests that results can be explained through reference to a Kuhnian (1962/1996) paradigm conflict – in which the school’s administrative and curricular committee and other members of the CCSDL were unsuccessful in convincing members of the science department (who, in turn, appeared to be supported by the provincial government, parents, and students) to make provisions for more student-directed, openended science inquiry. Assuming that student-led scientific inquiry continues to be an important curricular goal, efforts must continue to be made, therefore, to convince members of the mainstream paradigm that it is a worthy goal.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号