排序方式: 共有119条查询结果,搜索用时 15 毫秒
21.
Giuseppe Lippi Patrizia Bonelli Laura Bonfanti Gianfranco Cervellin 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(1):69-72
Background
Due to the high prevalence of hemolysis in specimens received from the emergency department (ED), several strategies have been proposed to improve sample quality, but none of these seem effective to overcome the problem. In a preliminary study we showed that the use of S-Monovette blood collection system was effective to lower the risk of hemolysis in venous blood samples collected from intravenous catheters. This study was hence aimed to verify whether the replacement of a conventional vacuum system with S-Monovette may be effective to reduce the burden of hemolysis in the daily practice of a large urban ED.Materials and methods
The study was divided in two observational periods of 4 months each. In the former period, blood was collected from intravenous catheters using BD Vacutainer SST II Plus plastic serum tubes, whereas in the latter period the blood was drawn from intravenous catheters using S-Monovette blood tubes in aspiration mode. Sample hemolysis was automatically assessed in all serum samples by photometrical measurement.Results
The total number of hemolysed serum specimens was 624/14155 (4.41%) in the first phase of the study, and 342/13319 (2.57%) in the second phase of the study (P < 0.001).Conclusion
Results of our study confirm that the introduction of the Sarstedt S-Monovette blood tubes has reduced the hemolysis rate in the emergency department compared to the previously used BD Vacutainer® SST II Plus plastic serum tubes.Key words: preanalytical phase, hemolysis, blood specimen collection, catheter, emergency department 相似文献22.
Gabriel Lima-Oliveira Giuseppe Lippi Gian Luca Salvagno Martina Montagnana Geraldo Picheth Gian Cesare Guidi 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(2):218-223
Procedures involving phlebotomy are critical for obtaining diagnostic blood specimens and represent a well known and recognized problem, probably among the most important issues in laboratory medicine. The aim of this report is to show spurious hyperkalemia and hypocalcemia due to inadequate phlebotomy procedure. The diagnostic blood specimens were collected from a male outpatient 45 years old, with no clinical complaints. The tubes drawing order were as follows: i) clot activator and gel separator (serum vacuum tube), ii) K3EDTA, iii) a needleless blood gas dedicated-syringe with 80 I.U. lithium heparin, directly connected to the vacuum tube holder system. The laboratory testing results from serum vacuum tube and dedicated syringe were 4.8 and 8.5 mmol/L for potassium, 2.36 and 1.48 mmol/L for total calcium, respectively. Moreover 0.15 mmol/L of free calcium was observed in dedicated syringe. A new blood collection was performed without K3EDTA tube. Different results were found for potassium (4.7 and 4.5 mmol/L) and total calcium (2.37 and 2.38 mmol/L) from serum vacuum tube and dedicated syringe, respectively. Also free calcium showed different concentration (1.21 mmol/L) in this new sample when compared with the first blood specimen. Based on this case we do not encourage the laboratory managers training the phlebotomists to insert the dedicated syringes in needle-holder system at the end of all vacuum tubes. To avoid double vein puncture the dedicated syringe for free calcium determination should be inserted immediately after serum tubes before EDTA vacuum tubes. 相似文献
23.
The impact of the geographical origin of patents on the probability of an opposition being filed and a patent being revoked has been examined in this paper, after accounting for patent value indicators and industry specificities. The study is based on a dataset of approximately 450,000 EPO granted patents and 24,000 patent opposition cases in the years 2000–2008. We find that patents with a first priority in the US are less likely to be challenged, although they are relatively more likely to be revoked than patents with a priority in a member country of the European Patent Convention. Patents from Japan have less probability of being opposed and are less likely to be revoked than the other countries. A disaggregation of the European countries has revealed that patents with a German priority have a higher or similar likelihood of being opposed than patents from the other countries, with the exceptions of The Netherlands and Denmark. 相似文献
24.
Yan-Qiu Han Li Yan Lei Zhang Pei-Heng Ouyang Peng Li Giuseppe Lippi Zhi-De Hu 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2021,31(2)
IntroductionThe prognostic value of D-dimer (DD) in sepsis remains controversial. This study aimed to investigate the performance of DD for predicting sepsis mortality in the hospital and for identifying its potential correlates.Materials and methodsThe clinical and laboratory data of adult sepsis patients were extracted from the Medical Information Mart for Intensive Care III (MIMIC III, v1.4) database using the structured query language (SQL). The database contains critical illness admitted to the intensive care unit at Beth Israel Deaconess Medical Center between June 2001 and October 2012. The association between DD and mortality was investigated with receiver operating characteristic (ROC) curve, restricted cubic spline and logistic regression analysis. Subgroup analysis was also used for identifying DD correlates.ResultsThe study population consisted of 358 sepsis patients. Those who died during hospital stay (N = 160) had significantly higher DD values than those who survived (N = 198). The area under the ROC curve (AUC) of DD was 0.59 (P < 0.010). In subgroup analysis, white blood cell (WBC) count > 18 x109/L and vasopressor therapy significantly decreased DD diagnostic performance. Categorical DD value was independently associated with hospital mortality after sequential organ failure score (SOFA) and blood lactate adjustment. Restricted cubic spline analysis revealed a U-shape relationship between DD and in-hospital mortality.DiscussionWe conclude that the accuracy of DD for predicting in-hospital sepsis mortality depends on WBC count and vasopressor therapy. Both low and extremely elevated DD values are associated with higher risk of death. 相似文献
25.
Giuseppe Lippi Paola Avanzini Rosalia Aloe Gianfranco Cervellin 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(3):303-307
Introduction:
Blood collection through intravenous lines frequently causes spurious hemolysis. Due to specific structure, the tube holder Holdex® (Greiner Bio-One GmbH, Kremsmuenster, Austria) is supposed to prevent erythrocyte injury in samples collected from catheters, so that we planned a specific study to support this hypothesis.Materials and methods:
Blood was collected from emergency department (ED) patients with 20-gauge catheter. In patients with odd order numbers, first and second tubes were collected with conventional holder (BD Vacutainer One Use Holder, Becton Dickinson, Milan, Italy) and the third with Holdex, whereas in even patients first and second tubes were drawn with Holdex and the third using BD Vacutainer One Use Holder. The first tube was discarded, whereas the second and third were centrifuged and serum was tested for potassium, lactate dehydrogenase (LD) and hemolysis index.Results:
The final study population consisted in 60 ED patients. Concentrations of potassium (4.25 vs. 4.16 mmol/L; P = 0.031), LD (498 vs. 459 U/L; P = 0.039) and cell-free hemoglobin (0.42 vs. 0.22 g/L; P = 0.042) were higher in samples collected with BD Vacutainer One Use Holder than with Holdex. The mean bias of cell-free hemoglobin was −0.4 g/L in samples collected with Holdex. Although the frequency of samples with cell-free hemoglobin > 0.5 g/L was identical (17/60 vs. 17/60; P = 1.00), the frequency of those with concentrations >3.0 g/L was higher using BD Vacutainer One Use Holder than Holdex (4/60 vs. 0/60; P = 0.042).Conclusions:
The use of Holdex for drawing blood from intravenous lines may be effective for reducing gross hemolysis. 相似文献26.
Claudia Conti Chiara Colombo David Dellasega Mauro Matteini Marco Realini Giuseppe Zerbi 《Journal of Cultural Heritage》2011,12(4):372
This study is focused on the evaluation by μRaman mapping of the penetration depth achieved by ammonium oxalate treatment in different plaster specimens, a hot issue in the conservation field. The role of the carbonatic aggregate particles and the influence of the different variables of the treatment on the penetration depth and on the distribution of the newly-formed phase (whewellite) have been ascertained. Based on the results of μRaman mapping, analyses with Field Emission Scanning Electron Microscopy have been carried out in order to observe the whewellite crystals and the carbonatic aggregate particles involved in the reaction with ammonium oxalate. 相似文献
27.
Physiological characteristics of America's Cup sailors 总被引:2,自引:0,他引:2
Bernardi M Quattrini FM Rodio A Fontana G Madaffari A Brugnoli M Marchetti M 《Journal of sports sciences》2007,25(10):1141-1152
The aim of this study was to assess the physiological profile of America's Cup grinders and mastmen, by measuring energy expenditure during sailing and assessing their aerobic and anaerobic fitness. The study focused on estimating the energy used during grinding activity, by measuring oxygen uptake (VO(2)) during sail setting in real sailing conditions. In the laboratory, using an arm-cranking ergometer, we measured VO(2peak) during an incremental maximal exercise test and total energy expended during the effort and recovery phases of an all-out test that simulated grinding activity, in six grinders and mastmen and ten sailors of the same crew. Total energy used during grinding corresponded to 45% (s = 9) and 51% (s = 5) of that used in the all-out test (234 kJ, s = 21.7) for tacks and gybes, respectively. In both grinding activity and the all-out test, VO(2) increased during and after the effort. The "VO(2) top value" was 53% (s = 8.6), 68% (s = 5.5), and 78% (s = 3.1) of VO(2peak) (4.7 l . min(-1), s = 0.43) in tacks, gybes, and the all-out test, respectively. During fast sequences of grinding activity, the "VO(2) top value" reached 65% (s = 7.1) VO(2peak) in tacks and 91% (s = 3.3) VO(2peak) in gybes. Our results suggest that grinders and mastmen are characterized by a high anaerobic capacity but their performance can be improved by powering aerobic fitness, to increase this energy contribution to all-out efforts and to guarantee fast recovery when grinding activity is repeated with short rest intervals. 相似文献
28.
Giuseppe Lippi Gianfranco Cervellin Camilla Mattiuzzi 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(2):193-200
Background:
A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis.Materials and methods:
We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode.Results:
Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9–3.9 and random effect RR 1.07; 95% CI = 1.06–1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7–5.1 and RR 1.32; 95% CI = 1.24–1.40).Conclusions:
Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration. 相似文献29.
Glycogen phosphorylase isoenzyme BB in the diagnosis of acute myocardial infarction: a meta-analysis
Giuseppe Lippi Camilla Mattiuzzi Ivan Comelli Gianfranco Cervellin 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(1):78-82
Background
Early diagnosis is crucial for management of patients with suspected acute myocardial infarction (AMI). Among innovative and promising biomarkers, the recent interest raised on glycogen phosphorylase isoenzyme BB (GPBB) has prompted us to perform a meta-analysis of published studies.Materials and methods:
A systematic electronic search was carried out on PubMed, Web of Science and Google Scholar, with no date restriction, to retrieve all articles that have investigated the early diagnostic performance of GPBB in patients with suspected AMI, and directly reported or allowed calculation of sensitivity and specificity. A meta-analysis of the reported sensitivity and specificity of each study and pooled area under the curve (AUC) was then performed by random effect approach. Heterogeneity was assessed by I-square statistics.Results:
Eight studies were finally selected for analysis (941 subjects; 506 cases and 435 controls), with a high heterogeneity (I-squared, 86.3%). The resulting pooled estimates and 95% confidence interval were 0.854 (0.801–0.891) for sensitivity, 0.767 (0.713–0.815) for specificity, 0.826 (0.774–0.870) for negative predictive value, 0.802 (0.754–0.844) for positive predictive value, and 0.754 (0.602–0.907) for AUC. In those studies that have simultaneously assessed GPBB and a troponin immunoassay, the combination of these biomarkers did not significantly improve the performance of troponin alone.Conclusion:
GPBB does not meet the current requirements for an efficient diagnosis of AMI when used as a stand-alone test, whereas its combination with troponin merits further investigation in larger trials. 相似文献30.
Gabriel Lima-Oliveira Gian Luca Salvagno Elisa Danese Giorgio Brocco Gian Cesare Guidi Giuseppe Lippi 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(3):359-367