排序方式: 共有33条查询结果,搜索用时 15 毫秒
1.
Phytoremediation is emerging as a potential cost-effective solution for remediation of contaminated soils, and bioavailability
of metal in the soil for plant uptake is an important factor for successful phytoremediation. This study aimed at investigating
the ability of EDTA and citric acid for enhancing soil bioavailability of Cu and phytoremediation by Elsholtzia splendens
in two types of soils contaminated with heavy metals [i.e. mined soil from copper mining area (MS), and paddy soil (PS) polluted
by copper refining]. The results showed that addition of 2.5 mmol/kg EDTA significantly increased the H2O extractable Cu concentration from 1.20 to 15.78 mg/kg in MS and from 0.26 to 15.72 mg/kg in PS, and that shoot Cu concentration
increased 4-fold and 8-fold as compared to the control. There was no significant difference between the treatment with 5.0
mmol/kg EDTA and that with 2.5 mmol/kg EDTA, probably because that 2.5 mmol/kg EDTA was enough for elevating Cu bioavailability
to the maximum level. As compared with the control, citric acid had no marked effect on both soil extractable Cu and shoot
Cu concentration or accumulation. The results indicated that EDTA addition can increase the potential and efficiency of Cu
phytoextraction byE. splendens in polluted soils.
Project supported by the National Natural Science Foundation of China (No. 29977017) and the Science and Technology Ministry
of China (No. 2002CB410804) 相似文献
2.
Jun Lin Wei-ying Zheng Peng-ruo-feng Liu Ning Zhang Hui-ping Lin Yi-jing Fan Xin-hua Gu Oliver Vollrath Christian Mehl 《Journal of Zhejiang University. Science. B》2014,15(7):649-660
The aim of this study is to evaluate the influence of Tooth Mousse (TM) application, smear layer removal, and storage time on resin-dentin microtensile bond strength (μTBS). Dentin specimens were divided into two groups: (1) smear layer covered; (2) smear layer removed using 15% EDTA for 90 s. In each group, half the specimens were treated once with TM for 60 min. After bonding procedures using a two-step self-etching adhesive (Clearfil SE Bond (CSE); Kuraray Medical, Tokyo, Japan), an all-in-one adhesive (G-Bond (GB); GC Corp, Tokyo, Japan), and a total-etch adhesive (Adper Single Bond 2 (SB); 3M ESPE, St. Paul, MN, USA), the specimens were stored for 3 d or 6 months in deionized water at 37 °C, and μTBS was tested and analyzed. With the exception of SB (no TM application) and GB, the μTBS was significantly increased for CSE and SB using EDTA pre-conditioning and 3 d of storage (P≤0.001). Bond strength of GB decreased significantly when using EDTA (3 d storage, P<0.05). TM application only increased the μTBS of GB (no EDTA) and SB (with EDTA) after 3 d (P≤0.02). Comparing the adhesives after 3 d of storage, CSE exhibited the greatest μTBS values followed by GB and SB (P≤0.02). The factors of adhesive, EDTA, and TM did not show any significant impact on μTBS when specimens were stored for 6 months (P>0.05). The additional application of TM and EDTA for cavity preparation seems only to have a short-term effect, and no influence on μTBS of dentin bonds after a period of 6 months. 相似文献
3.
4.
Scrubbing of NO
x
from the gas phase with Fe(II)EDTA has been shown to be highly effective. A new biological method can be used to convert
NO to N2 and regenerate the chelating agent Fe(II)EDTA for continuous NO absorption. The core of this biological regeneration is how
to effectively simultaneous reduce Fe(III)EDTA and Fe(II)EDTA-NO, two mainly products in the ferrous chelate absorption solution.
The biological reduction rate of Fe(III)EDTA plays a main role for the NO
x
removal efficiency. In this paper, a bacterial strain identified asKlebsiella Trevisan sp. was used to demonstrate an inhibition of Fe(III)EDTA reduction in the presence of Fe(II)EDTA-NO. The competitive inhibition
experiments indicted that Fe(II)EDTA-NO inhibited not only the growth rate of the iron-reduction bacterial strain but also
the Fe(III)EDTA reduction rate. Cell growth rate and Fe(III)EDTA reduction rate decreased with increasing Fe(II)EDTA-NO concentration
in the solution.
Project (No. 20176052) supported by the National Natural Science Foundation of China and the Scientific Research Foundation
for Returned Overseas Chinese Scholars, Ministry of Education 相似文献
5.
对钝顶螺旋藻A9品系进行实验研究,证明其具有较强活性的胞内核酸酶并实验研究了抑制其活性的方法。实验结果显示:在培养液中添加EDTA浓度为2~4mmoL·L-1或高温(45℃或50℃)处理15min可明显抑制胞内核酸酶的活性。 相似文献
6.
Kopcinovic LM Pavic M 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2012,22(1):130-134
Platelet satellitism (PS) is a rare phenomenon observed in blood smears obtained from blood anticoagulated with EDTA. It is characterised by platelet rosetting around polymorphonuclear neutrophils and in rare cases around other blood cells. PS is a rare cause of pseudothrombocytopenia. References about the phenomenon of PS in medical literature are few. In this report we describe a case of PS fortunately noticed in one trauma patient. Furthermore, we discuss the possible pathophysiological mechanisms of PS proposed in the literature. To our knowledge this is the first case of PS reported in Croatia. 相似文献
7.
erif Ercan Bahri Ramadan Ozan Gerenli 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2021,31(2)
IntroductionA specific sequence is recommended for filling blood tubes during blood collection to prevent erroneous test results due to carryover of additives. However, requirement of this procedure is still debatable. This study was aimed to investigate the potassium ethylenediaminetetraacetic acid (K-EDTA) contamination in blood samples taken after a tube containing the additive during routine workflow. The study was also carried out to examine the effect of order of draw on potassium results, regardless of K-EDTA contamination.Materials and methodsIn 388 outpatients, to determine the probability of K-EDTA cross-contamination, blood was drawn sequentially into a serum tube, followed by a tube containing K-EDTA, and by another serum tube. In another 405 outpatients, to evaluate the effect of order of draw blood unrelated to K-EDTA contamination, two serum tube were successively collected. Potassium was measured on Cobas 6000 c501 analyser (Roche Diagnostic GmbH, Mannheim, Germany) by indirect ion selective electrode method.ResultsOf paired samples collected before and after a K-EDTA tube, 24% had a potassium difference of above 0.3 mmol/L. However, no EDTA contamination was detected in these samples as well as 95% confidence intervals (CI) of limits of agreement for calcium were within the allowable error limits based on reference change values. Interestingly, of blood samples drawn successively, 24% had also a difference greater than 0.3 mmol/L for potassium.ConclusionIncorrect order of draw using closed blood collection system does not cause K-EDTA contamination, even in routine workflow. However, regardless of K-EDTA contamination, order of draw has significant influence on the potassium results. 相似文献
8.
Gabriel Lima-Oliveira Gian Luca Salvagno Elisa Danese Giorgio Brocco Gian Cesare Guidi Giuseppe Lippi 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(3):359-367
Introduction:
The contamination of serum or lithium heparin blood with ethylenediaminetetraacetic acid (EDTA) salts may affect accuracy of some critical analytes and jeopardize patient safety. The aim of this study was to evaluate the effect of lithium heparin sample contamination with different amounts of K2EDTA.Materials and methods:
Fifteen volunteers were enrolled among the laboratory staff. Two lithium heparin tubes and one K2EDTA tube were collected from each subject. The lithium-heparin tubes of each subject were pooled and divided in 5 aliquots. The whole blood of K2EDTA tube was then added in scalar amount to autologous heparinised aliquots, to obtained different degrees of K2EDTA blood volume contamination (0%; 5%; 13%; 29%; 43%). The following clinical chemistry parameters were then measured in centrifuged aliquots: alanine aminotranspherase (ALT), bilirubin (total), calcium, chloride, creatinine, iron, lactate dehydrogenase (LD), lipase, magnesium, phosphate, potassium, sodium.Results:
A significant variation starting from 5% K2EDTA contamination was observed for calcium, chloride, iron, LD, magnesium (all decreased) and potassium (increased). The variation of phosphate and sodium (both increased) was significant after 13% and 29% K2EDTA contamination, respectively. The values of ALT, bilirubin, creatinine and lipase remained unchanged up to 43% K2EDTA contamination. When variations were compared with desirable quality specifications, the bias was significant for calcium, chloride, LD, magnesium and potassium (from 5% K2EDTA contamination), sodium, phosphate and iron (from 29% K2EDTA contamination).Conclusions:
The concentration of calcium, magnesium, potassium, chloride and LD appears to be dramatically biased by even modest K2EDTA contamination (i.e., 5%). The values of iron, phosphate, and sodium are still reliable up to 29% K2EDTA contamination, whereas ALT, bilirubin, creatinine and lipase appear overall less vulnerable towards K2EDTA contamination. 相似文献9.
Gabriel Lima-Oliveira Giuseppe Lippi Gian Luca Salvagno Martina Montagnana Geraldo Picheth Gian Cesare Guidi 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(2):218-223
Procedures involving phlebotomy are critical for obtaining diagnostic blood specimens and represent a well known and recognized problem, probably among the most important issues in laboratory medicine. The aim of this report is to show spurious hyperkalemia and hypocalcemia due to inadequate phlebotomy procedure. The diagnostic blood specimens were collected from a male outpatient 45 years old, with no clinical complaints. The tubes drawing order were as follows: i) clot activator and gel separator (serum vacuum tube), ii) K3EDTA, iii) a needleless blood gas dedicated-syringe with 80 I.U. lithium heparin, directly connected to the vacuum tube holder system. The laboratory testing results from serum vacuum tube and dedicated syringe were 4.8 and 8.5 mmol/L for potassium, 2.36 and 1.48 mmol/L for total calcium, respectively. Moreover 0.15 mmol/L of free calcium was observed in dedicated syringe. A new blood collection was performed without K3EDTA tube. Different results were found for potassium (4.7 and 4.5 mmol/L) and total calcium (2.37 and 2.38 mmol/L) from serum vacuum tube and dedicated syringe, respectively. Also free calcium showed different concentration (1.21 mmol/L) in this new sample when compared with the first blood specimen. Based on this case we do not encourage the laboratory managers training the phlebotomists to insert the dedicated syringes in needle-holder system at the end of all vacuum tubes. To avoid double vein puncture the dedicated syringe for free calcium determination should be inserted immediately after serum tubes before EDTA vacuum tubes. 相似文献
10.
研究了合成1,4-丁二磺酸二钠盐的工艺。在1,4-丁二磺酸二钠盐的合成过程中,由于在反应体系中加入表面活性剂EDTA,最佳反应时间只要约3 h,与文献[1]中长达36 h相比,大大缩短了反应时间,反应平均转化率为99.39%。建立了用高效毛细管电泳(HPCE)测定1,4-丁二磺酸的定量分析方法。分析条件为:非涂层毛细管柱为50μm×81 cm(AGILENT),缓冲液:20 mmol硼砂溶液(pH=9.24),检测波长:191.2 nm,电压进样,进样电压30 kV,进样时间5 s。对标准曲线、精密度、准确度及重现性进行了研究。该方法的线性相关系数0.999,日内变异系数0.8%,日间变异系数0.5%,回收率96.5%。HPCE法具有准确性高、重现性好、灵敏度高及快速测定的优点,非常适合于1,4-丁二磺酸二钠盐含量的测定。 相似文献