首页 | 本学科首页   官方微博 | 高级检索  
     检索      

浅谈110kV SF_6封闭式组合电器检修
引用本文:卢伟洪.浅谈110kV SF_6封闭式组合电器检修[J].江西电力职业技术学院学报,2009,22(4).
作者姓名:卢伟洪
作者单位:深圳供电局,广东,深圳,518020
摘    要:介绍ZF4A-126型气体绝缘金属封闭开关设备的结构、工作原理、技术参数;总结和介绍110kV SF6封闭式组合电器的检修步骤,检修设备所涉及的SF6气体处理、工艺要求等注意事项及人身安全防护,并提出合理化建议。

关 键 词:SF6封闭式组合电器(GIS)  SF6气体绝缘  设备检修步骤

Maintenance of 110kV SF6 Gas-insulated Switchgear
LU Wei-hong.Maintenance of 110kV SF6 Gas-insulated Switchgear[J].Journal of Jiangxi Vocational and Technical College of Electricity,2009,22(4).
Authors:LU Wei-hong
Abstract:The ZF4A-126-type gas-insulated metal-enclosed switchgear's structure,working principle,technical parameters are introduced;110kV SF6 enclosed switchgear's maintenance steps involved in maintenance of equipment to deal with SF6 gas,process requirements notes and personal safety protection are summarized and introduced,and Some suggestions are proposed.
Keywords:Gas-Insulated Switchgear  gas-insulated  maintenance steps
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号