Simulation of Variable Air Volume System with Different Duct Layout
引用本文:陈华,涂光备,FRANCIS W H Yik. Simulation of Variable Air Volume System with Different Duct Layout[J]. 天津大学学报(英文版), 2004, 10(1): 24-28
作者姓名:陈华  涂光备  FRANCIS W H Yik
作者单位:[1]SchoolofEnvironmentalScienceandEngineering,TianjinUniversity,Tianjin300072,China [2]DepartmentofBuildingServiceEngineering,HongKongPolytechnicUniversity,HongKong,China
摘    要:The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was used to predict the system performance and zone air temperature of two kinds of layouts that were applied to a typical floor of an existing building office in Hong Kong. The position where the static pressure sensor was placed should affect the zones temperature and energy consumption. The comparison of predictions of the two kinds of layouts indicates that with the same DSPR control method the layout of the air duct might influence the fan control result and energy savings.

关 键 词:可变空气体积系统 管道静态压力重排 DSPR VAV 商业建筑

Simulation of Variable Air Volume System with Different Duct Layout
CHEN Hua ,TU Guang bei ,FRANCIS W H Yik. Simulation of Variable Air Volume System with Different Duct Layout[J]. Transactions of Tianjin University, 2004, 10(1): 24-28
Authors:CHEN Hua   TU Guang bei   FRANCIS W H Yik
Affiliation:1. School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
2. Department of Building Service Engineering, Hong Kong Polytechnic University, Hong Kong, China
Abstract:The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was used to predict the system performance and zone air temperature of two kinds of layouts that were applied to a typical floor of an existing building office in Hong Kong. The position where the static pressure sensor was placed should affect the zones temperature and energy consumption. The comparison of predictions of the two kinds of layouts indicates that with the same DSPR control method the layout of the air duct might influence the fan control result and energy savings.
Keywords:variable air volume (VAV) system simulation  air duct layout  duct static pressure reset control