摘    要:通过对晋城市巴公污水处理厂工艺改进前后两年同期运行数据的对比发现:COD去除率比较稳定,但在问一水温奈件下,技改后的C01)去除率略高于技改前;技改后NH3-N去除率2009年前半年有一定提高,后半年效果不明显,但出水总氯浓度有所降低;污泥负荷不稳定,相同污泥负荷条件下,技改后的NH3-N去除率高于技改前基于对主要影响因子的分析,建议在厌氧段前增设缓冲池稳定进水水质,提高碳氛比,在曝气池前加加热池、用废弃蒸汽或电加热等手段增强保温等措施、

关 键 词:工艺改进  COD去除率  NH3-N去除率  污泥负荷  溶解氧浓度

Contrastive Analysis and Study of Bagong Sewage Treatment Plant in Jincheng City around Technical Transformation
JI Jin-lan,WANG Qiang. Contrastive Analysis and Study of Bagong Sewage Treatment Plant in Jincheng City around Technical Transformation[J]. Journal of Jincheng Institute of Technology, 2010, 3(2): 63-66. DOI: 10.3969/j.issn.1674-5078.2010.02.021
Authors:JI Jin-lan  WANG Qiang
Affiliation:JI Jin-lan, WANag Qiang ( 1.Jincheng institute cf technology, Jincheng,Shcmxi 048026 ; 2.Bagong sewage trecament plcmt in Jincheng city, Jincheng, Shcmxi 048000, China )
Abstract:Through the Contrastive analysis and study of Bagong sewage treatment plant around technical transformation,we find that COD removal rate was relatively stable,hut at the same temperature conditions, COD removal rate was slightly higher after the technological transfornlation;NH3-N removal rate in the first half of 2009 was better and lhe effluent TN concentration was reduced;Sludge load is unstable,and NH3-N is higher after the technological transformation. Based on the analysis of the main effect factors,to add a buffer pool before the anaerobic slage lo stahle the sewage qualily,increase the earbon-nitrogen ratio and improve the insulation measures by using waste heat or an additional thermal pool are suggested.
Keywords:teehnieal translormation  COD removal rate  NH3-N removal rate  sludge load  DO concentration