首页 | 本学科首页   官方微博 | 高级检索  
     

Determination of Trace Molybdenum(VI) by Oscillographic Potentiometric Catalyzing Kinetic Method of Simplex Optimization
引用本文:穆挺,丁亚平,吴庆生,马红燕. Determination of Trace Molybdenum(VI) by Oscillographic Potentiometric Catalyzing Kinetic Method of Simplex Optimization[J]. 上海大学学报(英文版), 2004, 8(3): 360-363. DOI: 10.1007/s11741-004-0079-2
作者姓名:穆挺  丁亚平  吴庆生  马红燕
作者单位:Department of Chemistry,College of Sciences,Shanghai University,Shanghai 200436,P.R. China,Department of Chemistry,College of Sciences,Shanghai University,Shanghai 200436,P.R. China,Department of Chemistry,College of Sciences,Tongji University,Shanghai 200092,P.R. China,Department of Chemistry,College of Sciences,Shanghai University,Shanghai 200436,P.R. China
基金项目:SupportedbytheNationalNaturalScienceFoundationofChina(GrantNo .2 0 175 0 13 )andtheHigherEducationDevelopmentFoundationofShanghaiinChina (GrantNo .0 1A17)
摘    要:1 Introduction Ahugeamountofliteratureexistsonthestudyofi dentifyingtracemetalionsbymeansofspectropho tometry[1 3] ,fluorimetry[4 6 ] aswellas polarogra phy[7 9] ,whichhaveactiononlocatingtheendpointoftheindicatingreaction .Howeverbothspectropho tometryandfluorimetryareeasytobeinterferedbycolororprecipitation ,whilepolarographyhasanissueofmercurypollution .Thecatalyzingkineticanalysishasthecharacteristicsofhighsensitivityandspeedi ness.Oscillographicpotentiometryisasimpleintu itionisticanal…

关 键 词:电势计示波法 催化动力学 单纯最优化 钼 示踪法 废水处理
收稿时间:2003-07-27

Determination of trace molybdenum (VI) by oscillographic potentiometric catalyzing kinetic method of simplex optimization
Mu Ting,Ding Ya-ping,Wu Qing-sheng,Ma Hong-yan. Determination of trace molybdenum (VI) by oscillographic potentiometric catalyzing kinetic method of simplex optimization[J]. Journal of Shanghai University(English Edition), 2004, 8(3): 360-363. DOI: 10.1007/s11741-004-0079-2
Authors:Mu Ting  Ding Ya-ping  Wu Qing-sheng  Ma Hong-yan
Affiliation:(1) Department of Chemistry, College of Sciences, Shanghai University, 200436 Shanghai, P.R. China;(2) Department of Chemistry, College of Sciences, Tongji University, 200092 Shanghai, P.R. China
Abstract:Under the optimum experimental conditions (i. e., pH=1.6, c KI=10.6 mmol/L, 
$$c_{H_2 O_2 } $$
=5.4 mmol/L, 
$$c_{C_6 H_8 O_6 } $$
=1.30 mmol/L) derived from simplex operations, trace molybdenum(VI) was determined through the agency of its catalytic effect on the reaction of H2O2 with I in acid medium. The detection limit and linear calibration range of molybdenum were obtained as 0.5×10−6 mol/L and 0.5×10−6∼120×10−6mol/L respectively. This method was applied to the examination of the industrial waste water, and the recovery ratios were found to be in the range of 101% and 107%. Supported by the National Natural Science Foundation of China (Grant No. 20175013) and the Higher Education Development Foundation of Shanghai in China (Grant No. 01A17)
Keywords:oscillographic potentiometry   catalyzing kinetic analysis   simplex optimization   molybdenum.
本文献已被 CNKI SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号