华能汕头电厂2号机闭冷器改造
引用本文:蓝月华. 华能汕头电厂2号机闭冷器改造[J]. 茂名学院学报, 2005, 15(3): 51-53
作者姓名:蓝月华
作者单位:茂港电力设备厂,广东,茂名,525000
摘    要:针对华能汕头电厂2号机铜管折流板式闭冷器运行中存在的问题,通过对其分析,决定采用折流杆技术对该闭冷器进行改造。改造后的闭冷器,其传热、阻力和振动等重要性能都大大优于原来的闭冷器,且换热管断裂问题得到解决。

关 键 词:折流杆  闭冷器  振动  节能  高效
文章编号:1671-6590(2005)03-0051-03
修稿时间:2005-01-21

Reconstruction of NO. 2 Circle Cooling Water Heat Exchanger of Huaneng Shantou Power Plant
LAN Yue-hua. Reconstruction of NO. 2 Circle Cooling Water Heat Exchanger of Huaneng Shantou Power Plant[J]. Journal of Maoming College, 2005, 15(3): 51-53
Authors:LAN Yue-hua
Abstract:The baffle-rod technique is adopted to solve the problem of the copper tube baffle-sheet type circle cooling water heat exchanger of NO. 2 machine of HuaNeng Shantou Power Plant. The reconstructed exchanger gains higher efficiency, longer life, and is more energy-saving in heat-driving, resistance and vibration. The problem of tube splitting is also solved thereby.
Keywords:baffle-rod  circle cooling water heat exchanger  splitting  energy-saving  high efficiency