首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Automatic segmentation of bladder in CT images
Authors:Feng Shi  Jie Yang  Yue-min Zhu
Institution:(1) Institute of Image Processing and Pattern Recognition, Shanghai Jiao Tong University, Shanghai, 200240, China;(2) CREATIS, INSA of Lyon, University of Lyon 1, Villeurbanne, France
Abstract:Segmentation of the bladder in computerized tomography (CT) images is an important step in radiation therapy planning of prostate cancer. We present a new segmentation scheme to automatically delineate the bladder contour in CT images with three major steps. First, we use the mean shift algorithm to obtain a clustered image containing the rough contour of the bladder, which is then extracted in the second step by applying a region-growing algorithm with the initial seed point selected from a line-by-line scanning process. The third step is to refine the bladder contour more accurately using the rolling-ball algorithm. These steps are then extended to segment the bladder volume in a slice-by-slice manner. The obtained results were compared to manual segmentation by radiation oncologists. The average values of sensitivity, specificity, positive predictive value, negative predictive value, and Hausdorff distance are 86.5%, 96.3%, 90.5%, 96.5%, and 2.8 pixels, respectively. The results show that the bladder can be accurately segmented.
Keywords:Image segmentation  Computerized tomography (CT)  Mean shift  Bladder  Rolling ball
本文献已被 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏