首页 | 本学科首页   官方微博 | 高级检索  
     检索      

水平与垂直PES中空纤维超滤膜组件分离性能的研究
引用本文:许振良,杨晓天.水平与垂直PES中空纤维超滤膜组件分离性能的研究[J].上海大学学报(英文版),2006,10(2):173-178.
作者姓名:许振良  杨晓天
作者单位:Chemical Engineering Research Center East China University of Science and Technology Shanghai 200237 P.R. China,Chemical Engineering Research Center East China University of Science and Technology Shanghai 200237 P.R. China,Chemical Engineering Research Center East China University of Science and Technology Shanghai 200237 P.R. China
基金项目:ProjectsupportedbyNationalBasicResearchProgramofChina(“973”Plan,GrantNo.2003CB615705),andNationalNaturalScienceFoundationofChina(GrantNo.20076009)
摘    要:1Introduction Generally,ultrafiltration(UF)asaseparationtech nologyofhighefficiencyandlowenergyconsumption haswidelybeenappliedinvariousindustries.Inin dustrialapplications,therearesixbasicUF modules1]:(1)tubular,withinnerchannel diameters>4mm;(2)hollowfibers,withinnerdia metersof0.2-3mm;(3)plateunits;(4)spiral woundmodules;(5)pleated sheetcartridges;and(6)rotarymodules.However,hollowfiberUFmoduleis oneofmostimportantmodulesbecauseofitshigh areapackingdensity.Besides,UFtechnologyalsois us…

关 键 词:聚醚砜  聚乙烯醇  水平模数  垂直模数  分离性能  中空纤维超滤膜组件
文章编号:1007-6417(2006)02-0173-06
收稿时间:2004-09-31
修稿时间:2004-12-27

Separation performance of horizontal and vertical polyethersulfone hollow fiber UF modules
Qusay Fadhel Alsalhy Ph. D. Candidate,Zhen-liang Xu Ph. D.,Xiao-tian Yang.Separation performance of horizontal and vertical polyethersulfone hollow fiber UF modules[J].Journal of Shanghai University(English Edition),2006,10(2):173-178.
Authors:Qusay Fadhel Alsalhy Ph D Candidate  Zhen-liang Xu Ph D  Xiao-tian Yang
Institution:Chemical Engineering Research Center, East China University of Science and Technology, Shanghai 200237, P.R. China
Abstract:The effect of hollow fiber module positions (horizontal and vertical) on separation performance for PVA solution by using polyethersulfone (PES) hollow fiber ultrafiltration (UF) membrane with the molecular weight cut-off (MWCO) 30 000 has been discussed. Experimental results illustrated that the suitable operation conditions for PVA solution were as follows: trans-membrane pressure 2.1 bar, solution temperature 75 °C and feed velocity 0.32 m/s. Under these suitable operation conditions, the permeate flux is from 36.8 L/(m2·h· bar) to 42.9 L/(m2· h· bar) for the horizontal module and from 39.8 L/(m2· h· bar) to 66.6 L/(m2· h· bar) for the vertical module. Besides, the separation performance of PES hollow fiber UF membrane was better by using vertical hollow fiber module than by using horizontal hollow fiber module. When the trans-membrane pressure increased from 1 bar to 2.1 bar, solution temperature from 50 °C to 75 °C, feed solution velocity from 0.16 m/s to 0.32 m/s, the PVA rejection would increase from 95.8% to 99.7%, 95.4% to 98.6%, 95.8% to 99.2% for horizontal module respectively, and from 98.8% to 99.8%, 98.6% to 99.4%, 98.5% to 99.4% for vertical module respectively. Therefore, PVA rejection in PES hollow fiber UF process was more than 98.5% for vertical module, and it is suitable for PVA recovery from wastewater. Project supported by National Basic Research Program of China (“973” Plan, Grant No. 2003CB615705), and National Natural Science Foundation of China (Grant No. 20076009)
Keywords:hollow fiber UF membrane  polyethersulfone  polyvinyl alcohol  horizontal module  vertical module  
本文献已被 CNKI 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号