High density porous polyethylene material (Medpor) as an unwrapped orbital implant
作者姓名:Chen YH  Cui HG
作者单位:Department of Eye Center, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310015, China
摘    要:Objective: To introduce the clinical effect among patients who received an unwrapped orbital implant with high density porous polyethylene material (Medpor) after enucleation or evisceration. Methods: Retrospective analysis of a series of 302 patients with anophthalmia who underwent placement of an unwrapped high density porous polyethylene orbital implant. We compared the patients (n=180) who accepted primary implant placement with those (n=122) who accepted secondary implant placement. Parameters evaluated included: age at time of surgery, date of surgery, sex, implant type and size, surgery type, the surgical procedure and technique performed, and complications. Results: The time of follow-up ranged from 2.0 to 58.0 months (mean 32.5 months). A total of 5 of 302 (1.66%) cases had documented postoperative complications. The following problems were noted after surgery: implant exposure, 3 patients (0.99%); implant removed due to orbital infection, 1 patient (0.34%); ptosis, 1 patient (0.34%). There were no significant complications'observed in other 297 cases and all implants showed good orbital motility. The clinical effect of primary implant placement is better than that of secondary placement. Conclusion: High density porous polyethylene material can be used successfully as an unwrapped orbital implant in anopthalmic socket surgery with minimal complications. The material is well tolerated, nonantigenic and has low rate of infection and migration.

关 键 词:眼眶植入物  高密度多孔聚乙烯  眼眶畸形  生物材料
收稿时间:2006-03-27
修稿时间:2006-06-22

High density porous polyethylene material (Medpor) as an unwrapped orbital implant
Chen YH,Cui HG.High density porous polyethylene material (Medpor) as an unwrapped orbital implant[J].Journal of Zhejiang University Science,2006,7(8):679-682.
Authors:Yan-hong Chen  Hong-guang Cui
Institution:(1) Department of Eye Center, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310015, China
Abstract:Objective: To introduce the clinical effect among patients who received an unwrapped orbital implant with high density porous polyethylene material (Medpor) after enucleation or evisceration. Methods: Retrospective analysis of a series of 302 patients with anophthalmia who underwent placement of an unwrapped high density porous polyethylene orbital implant. We compared the patients (n=180) who accepted primary implant placement with those (n=122) who accepted secondary implant placement. Parameters evaluated included: age at time of surgery, date of surgery, sex, implant type and size, surgery type, the surgical procedure and technique performed, and complications. Results: The time of follow-up ranged from 2.0 to 58.0 months (mean 32.5 months). A total of 5 of 302 (1.66%) cases had documented postoperative complications. The following problems were noted after surgery: implant exposure, 3 patients (0.99%); implant removed due to orbital infection, 1 patient (0.34%); ptosis, 1 patient (0.34%). There were no significant complications observed in other 297 cases and all implants showed good orbital mo- tility. The clinical effect of primary implant placement is better than that of secondary placement. Conclusion: High density porous polyethylene material can be used successfully as an unwrapped orbital implant in anopthalmic socket surgery with minimal complications. The material is well tolerated, nonantigenic and has low rate of infection and migration.
Keywords:Orbital implants  High density porous polyethylene  Correction of orbital abnormality