首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Prediction of 2000 m indoor rowing performance using a 30 s sprint and maximal oxygen uptake
Authors:Steven E Riechman  Robert F Zoeller  G Balasekaran  Fredric L Goss  Robert J Robertson
Abstract:The aim of this study was to predict indoor rowing performance in 12 competitive female rowers (age 21.3 - 3.6 years, height 1.68 - 0.54 m, body mass 67.1 - 11.7 kg; mean - s ) using a 30 s rowing sprint, maximal oxygen uptake and the blood lactate response to submaximal rowing. Blood lactate and oxygen uptake ( V O 2 ) were measured during a discontinuous graded exercise test on a Concept II rowing ergometer incremented by 25 W for each 2 min stage; the highest V O 2 measured during the test was recorded as V O 2max (mean = 3.18 - 0.35 l· min -1 ). Peak power (380 - 63.2 W) and mean power (368 - 60.0 W) were determined using a modified Wingate test protocol on the Concept II rowing ergometer. Rowing performance was based on the results of the 2000 m indoor rowing championship in 1997 (466.8 - 12.3 s). Laboratory testing was performed within 3 weeks of the rowing championship. Submitting mean power (Power), the highest and lowest five consecutive sprint power outputs (Maximal and Minimal), percent fatigue in the sprint test (Fatigue), V O 2max (l· min -1 ), V O 2max (ml·kg -1 ·min -1 ), V O 2 at the lactate threshold, power at the lactate threshold (W), maximal lactate concentration, lactate threshold (percent V O 2max ) and V E max (l·min -1 ) to a stepwise multiple regression analysis produced the following model to predict 2000 m rowing performance: Time 2000 =- 0.163 (Power)14.213 ·( V O 2max l· min -1 ) + 0.738· (Fatigue) + 567.259 ( R 2 = 0.96, standard error = 2.89). These results indicate that, in the women studied, 75.7% of the variation in 2000 m indoor rowing performance time was predicted by peak power in a rowing Wingate test, while V O 2max and fatigue during the Wingate test explained an additional 12.1% and 8.2% of the variance, respectively.
Keywords:Lactate  Maximal Oxygen Uptake  Multiple Regression  Wingate Test  Women
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号